Determination of central aortic systolic and pulse pressure from the radial artery pressure waveform

被引:40
作者
Adji, A [1 ]
O'Rourke, MF [1 ]
机构
[1] Univ New S Wales, St Vincents Clin, Darlinghurst, NSW 2010, Australia
关键词
aortic systolic pressure; aortic pulse pressure; arterial pressure waveform;
D O I
10.1097/01.mbp.0000132426.32886.e0
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective Measurements of central aortic systolic and pulse pressure, either gauged directly or estimated indirectly, have been shown to be superior to brachial pressure in outcome studies. While the radial pressure convolution method has proved to satisfy the criteria for 'substantial equivalence' to measure central pressure non-invasively, this study sought simpler methods to generate central systolic and pulse pressure directly from the radial artery waveform. Methods Two sets of data were used, in which radial artery pressure waves were measured by applanation tonometry and ascending aortic pressure was generated by the SphygmoCor((R)) process. Different approaches were applied to each dataset: firstly, using the time period from wave foot to systolic peak in central arteries; secondly, through identifying the pressure surge from the reflected wave in the radial artery; and thirdly from extrapolation and calibration of carotid systolic pressure when mean and diastolic pressure considered to be equal with radial values. Results Both datasets showed good correspondence between the central systolic and pulse pressure obtained with each of the three approaches and respective pressures generated by SphygmoCor((R)) process; all were within AAMI SP10 criteria and grade A for BSH criteria. Conclusion All three approaches gave results similar substantially equivalent to those obtained with the SphygmoCor((R)) system for aortic, systolic and pulse pressure. Hence, simple inspection of the radial waveform has the potential to improve the estimation of aortic systolic and pulse pressure. (C) 2004 Lippincott Williams Wilkins.
引用
收藏
页码:115 / 121
页数:7
相关论文
共 18 条
[1]   Local pulse pressure and regression of arterial wall hypertrophy during long-term antihypertensive treatment [J].
Boutouyrie, P ;
Bussy, C ;
Hayoz, D ;
Hengstler, J ;
Dartois, N ;
Laloux, B ;
Brunner, H ;
Laurent, S .
CIRCULATION, 2000, 101 (22) :2601-2606
[2]  
Chemla Denis, 2002, American Journal of Hypertension, V15, p164A, DOI 10.1016/S0895-7061(02)02719-X
[3]  
De Luca N, 2002, J HYPERTENS, V20, pS164
[4]   NONINVASIVE DETERMINATION OF AORTIC INPUT IMPEDANCE AND EXTERNAL LEFT-VENTRICULAR POWER OUTPUT - A VALIDATION AND REPEATABILITY STUDY OF A NEW TECHNIQUE [J].
KELLY, R ;
FITCHETT, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (04) :952-963
[5]   Pulsatility of ascending aorta and restenosis after coronary angioplasty in patients >60 years of age with stable angina pectoris [J].
Lu, TM ;
Hsu, NW ;
Chen, YH ;
Lee, WS ;
Wu, CC ;
Ding, YA ;
Chang, MS ;
Lin, SJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (09) :964-968
[6]   Pulsatility of ascending aortic pressure waveform is a powerful predictor of restenosis after percutaneous transluminal coronary angioplasty [J].
Nakayama, Y ;
Tsumura, K ;
Yamashita, N ;
Yoshimaru, K ;
Hayashi, T .
CIRCULATION, 2000, 101 (05) :470-472
[7]  
Nichols WW., 1998, MCDONALDS BLOOD FLOW, V4
[8]   Pulsatility of ascending aortic blood pressure waveform is associated with an increased risk of coronary heart disease [J].
Nishijima, T ;
Nakayama, Y ;
Tsumura, K ;
Yamashita, N ;
Yoshimaru, K ;
Ueda, H ;
Hayashi, T ;
Yoshikawa, J .
AMERICAN JOURNAL OF HYPERTENSION, 2001, 14 (05) :469-473
[9]   Blood pressure measuring devices: recommendations of the European Society of Hypertension [J].
O'Brien, E ;
Waeber, B ;
Parati, G ;
Staessen, J ;
Myers, MG .
BMJ-BRITISH MEDICAL JOURNAL, 2001, 322 (7285) :531-536
[10]  
OROURKE M, 1992, ARTERIAL VASODILATIO