NONINVASIVE DETERMINATION OF AORTIC INPUT IMPEDANCE AND EXTERNAL LEFT-VENTRICULAR POWER OUTPUT - A VALIDATION AND REPEATABILITY STUDY OF A NEW TECHNIQUE

被引:286
作者
KELLY, R [1 ]
FITCHETT, D [1 ]
机构
[1] MCGILL UNIV,ROYAL VICTORIA HOSP,DIV CARDIOL,687 PINE AVE W,MONTREAL H3A 1A1,QUEBEC,CANADA
关键词
D O I
10.1016/0735-1097(92)90198-V
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. The study was designed to test whether aortic input impedance and left ventricular power output can be accurately assessed noninvasively. Background. Aortic input impedance describes both the pulsatile and nonpulsatile artery load encountered by the left ventricle. Until now, this measure of afterload has only been determined by invasive techniques. Methods. The aortic pressure wave was estimated by recording the calibrated carotid artery pressure wave noninvasively with use of a micromanometer-tipped probe by the technique of applanation tonometry. Flow was determined with pulsed wave Doppler measurement of ascending aortic velocity profile and aortic diameter. In 18 subjects undergoing cardiac catheterization, invasive measurements were taken to assess the accuracy of noninvasive data. In 17 other subjects noninvasive measurements were taken on different days to assess the reproducibility of results. Results. Noninvasive pressure measurements correlated well with invasive data: systolic pressure (mm Hg), noninvasive 126 +/- 28 versus invasive 127 +/- 28, r = 0.96, p < 0.001; diastolic pressure (mm Hg), noninvasive 71 +/- 10 versus invasive 66 +/- 7, r = 0.60, p < 0.02; augmentation index (%), noninvasive 23.9 +/-9.3 versus invasive 30.7 +/- 11.9, r = 0.87, p < 0.001. Doppler-measured cardiac output was closely correlated with invasively measured flow (liters/min): Doppler, 5.3 +/- 1.2 versus invasive, 5.5 +/- 1.3, r = 0.98, p < 0.001. Impedance and left ventricular power variables calculated from noninvasive and invasive techniques were also closely related: systemic vascular resistance (dynes.s.cm-5), noninvasive 1,479 +/- 488 versus invasive 1,502 +/- 498, r = 0.91, p < 0.001; characteristic impedance (dynes.s.cm-5), noninvasive 137 +/- 52 versus invasive 136 +/- 79, r = 0.92, p < 0.001; pulsatile power (mW), noninvasive 249 +/- 94 versus invasive 291 +/- 103, r = 0.91, p < 0.001; mean power (mW), noninvasive 1,107 +/- 319 versus invasive 1,144 +/- 266, r = 0.93, p < 0.001. Repeated measures of impedance variables and power output showed coefficients of variation of < 9%. Conclusions. Measurement of noninvasive impedance by this technique provides an accurate and repeatable assessment of mean and pulsatile cardiac load.
引用
收藏
页码:952 / 963
页数:12
相关论文
共 32 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   A COMPARISON OF ENALAPRIL WITH HYDRALAZINE ISOSORBIDE DINITRATE IN THE TREATMENT OF CHRONIC CONGESTIVE-HEART-FAILURE [J].
COHN, JN ;
JOHNSON, G ;
ZIESCHE, S ;
COBB, F ;
FRANCIS, G ;
TRISTANI, F ;
SMITH, R ;
DUNKMAN, WB ;
LOEB, H ;
WONG, ML ;
BHAT, G ;
GOLDMAN, S ;
FLETCHER, RD ;
DOHERTY, J ;
HUGHES, CV ;
CARSON, P ;
CINTRON, G ;
SHABETAI, R ;
HAAKENSON, C .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 325 (05) :303-310
[4]   ARTERIAL TONOMETRY - REVIEW AND ANALYSIS [J].
DRZEWIECKI, GM ;
MELBIN, J ;
NOORDERGRAAF, A .
JOURNAL OF BIOMECHANICS, 1983, 16 (02) :141-152
[5]   COMPARATIVE ACCURACY OF DOPPLER ECHOCARDIOGRAPHIC METHODS FOR CLINICAL STROKE VOLUME DETERMINATION [J].
DUBIN, J ;
WALLERSON, DC ;
CODY, RJ ;
DEVEREUX, RB .
AMERICAN HEART JOURNAL, 1990, 120 (01) :116-123
[6]   REFLECTED PRESSURE WAVES IN THE ASCENDING AORTA - EFFECT OF GLYCERYL TRINITRATE [J].
FITCHETT, DH ;
SIMKUS, GJ ;
BEAUDRY, JP ;
MARPOLE, DGF .
CARDIOVASCULAR RESEARCH, 1988, 22 (07) :494-500
[7]   HEART-FAILURE - MECHANISMS OF CARDIAC AND VASCULAR DYSFUNCTION AND THE RATIONALE FOR PHARMACOLOGICAL INTERVENTION [J].
FRANCIS, GS ;
COHN, JN .
FASEB JOURNAL, 1990, 4 (13) :3068-3075
[8]  
Fujii M., 1989, J JPN COLL ANGIOL, V29, P545
[9]   EFFECTS OF CAPTOPRIL AND MINOXIDIL ON LEFT-VENTRICULAR HYPERTROPHY IN RESISTANT HYPERTENSIVE PATIENTS - A 6 MONTH DOUBLE-BLIND COMPARISON [J].
JULIEN, J ;
DUFLOUX, MA ;
PRASQUIER, R ;
CHATELLIER, G ;
MENARD, D ;
PLOUIN, PF ;
MENARD, J ;
CORVOL, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (01) :137-142
[10]   NONINVASIVE DETERMINATION OF AGE-RELATED-CHANGES IN THE HUMAN ARTERIAL PULSE [J].
KELLY, R ;
HAYWARD, C ;
AVOLIO, A ;
OROURKE, M .
CIRCULATION, 1989, 80 (06) :1652-1659