Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation - A randomized evaluation in patients in cardiac arrest

被引:123
作者
Plaisance, P
Lurie, KG
Payen, D
机构
[1] Lariboisiere Univ Hosp, Dept Anesthesiol & Crit Care, F-75475 Paris, France
[2] Univ Minnesota, Div Cardiovasc, Cardiac Arrhythmia Ctr, Minneapolis, MN 55455 USA
关键词
cardiopulmonary resuscitation; heart arrest; circulation; active compression-decompression;
D O I
10.1161/01.CIR.101.9.989
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Blood pressure is severely reduced in patients in cardiac arrest receiving standard cardiopulmonary resuscitation (CPR), Although active compression-decompression (ACD) CPR improves acute hemodynamic parameters, arterial pressures remain suboptimal with this technique. We performed ACD CPR in patients with a new inspiratory threshold valve (ITV) to determine whether lowering intrathoracic pressures during the "relaxation" phase of ACD CPR would enhance venous blood return and overall CPR efficiency. Methods and Results-This prospective, randomized, blinded trial was performed in prehospital mobile intensive care units in Paris, France. Patients in nontraumatic cardiac arrest received ACD CPR plus the ITV or ACD CPR alone for 30 minutes during advanced cardiac life support. End tidal CO2 (ETCO2), diastolic blood pressure (DAP) and coronary perfusion pressure, and time to return of spontaneous circulation (ROSC) were measured. Groups were similar with respect to age, gender, and initial rhythm. Mean maximal ETCO2, coronary perfusion pressure, and DAP values, respectively (in mm Hg), were 13.1+/-0.9, 25,0 +/- 1.4, and 36.5 +/- 1.5 with ACD CPR alone versus 19.1 +/- 1.0, 43.3 +/- 1.6, and 56.4 +/- 1.7 with ACD plus valve (P<0.001 between groups). ROSC was observed in 2 of 10 patients with ACD CPR alone after 26.5 +/- 0.7 minutes versus 4 of 11 patients with ACD CPR plus ITV after 19.8 +/- 2.8 minutes (P<0.05 for time from intubation to ROSC). Conclusions-Use of an inspiratory resistance valve in patients in cardiac arrest receiving ACD CPR increases the efficiency of CPR, leading to diastolic arterial pressures of >50 mm Hg. The long-term benefits of this new CPR technology are under investigation.
引用
收藏
页码:989 / 994
页数:6
相关论文
共 23 条
  • [1] [Anonymous], 1992, JAMA-J AM MED ASSOC, V268, P2184
  • [2] VENTILATORY EFFECTS OF ACTIVE COMPRESSION-DECOMPRESSION IN DOGS
    CARLI, PA
    DELACOUSSAYE, JE
    RIOU, B
    SASSINE, A
    ELEDJAM, JJ
    [J]. ANNALS OF EMERGENCY MEDICINE, 1994, 24 (05) : 890 - 894
  • [3] GUIDELINES FOR ADVANCED LIFE-SUPPORT
    CHAMBERLAIN, D
    BOSSAERT, L
    CARLI, P
    EDGREN, E
    EKSTROM, L
    HAPNES, S
    HOLMBERG, S
    KOSTER, R
    LINDNER, K
    PASQUALUCCI, V
    PERALES, N
    VONPLANTA, M
    ROBERTSON, C
    STEEN, P
    [J]. RESUSCITATION, 1992, 24 (02) : 111 - 121
  • [4] ACTIVE COMPRESSION-DECOMPRESSION CPR IMPROVES VITAL ORGAN PERFUSION IN A DOG-MODEL OF VENTRICULAR-FIBRILLATION
    CHANG, MW
    COFFEEN, P
    LURIE, KG
    SHULTZ, J
    BACHE, RJ
    WHITE, CW
    [J]. CHEST, 1994, 106 (04) : 1250 - 1259
  • [5] ACTIVE COMPRESSION-DECOMPRESSION - A NEW METHOD OF CARDIOPULMONARY-RESUSCITATION
    COHEN, TJ
    TUCKER, KJ
    LURIE, KG
    REDBERG, RF
    DUTTON, JP
    DWYER, KA
    SCHWAB, TM
    CHIN, MC
    GELB, AM
    SCHEINMAN, MM
    SCHILLER, NB
    CALLAHAM, ML
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 267 (21): : 2916 - 2923
  • [6] CUMMINS RO, 1991, ANN EMERG MED, V20, P861
  • [7] EXPIRED CARBON-DIOXIDE - A NONINVASIVE MONITOR OF CARDIOPULMONARY RESUSCITATION
    GUDIPATI, CV
    WEIL, MH
    BISERA, J
    DESHMUKH, HG
    RACKOW, EC
    [J]. CIRCULATION, 1988, 77 (01) : 234 - 239
  • [8] A comparison of repeated high doses and repeated standard doses of epinephrine for cardiac arrest outside the hospital
    Gueugniaud, PY
    Mols, P
    Goldstein, P
    Pham, E
    Dubien, PY
    Deweerdt, C
    Vergnion, M
    Petit, P
    Carli, P
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (22) : 1595 - 1601
  • [9] GULY UM, 1995, BRIT HEART J, V73, P372
  • [10] Optimizing standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve
    Lurie, KG
    Mulligan, KA
    McKnite, S
    Detloff, B
    Lindstrom, P
    Lindner, KH
    [J]. CHEST, 1998, 113 (04) : 1084 - 1090