Minimizing cardiopulmonary bypass attenuates myocardial damage after cardiac surgery

被引:41
作者
Skrabal, Christian A. [1 ]
Steinhoff, Gustav [1 ]
Liebold, Andreas [1 ]
机构
[1] Univ Rostock, Dept Cardiac Surg, D-18057 Rostock, Germany
关键词
D O I
10.1097/01.mat.0000249868.96923.1e
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The standard heart-lung machine is deemed a major trigger of systemic inflammatory reactions, potentially inducing organ failure. The strict reduction of blood-artificial surface and blood-air contact might represent meaningful improvements of the extracorporeal technology with respect to organ preservation. In this study, we assessed perioperative myocardial damage by using a novel minimal extracorporeal circuit (MECC) and a conventional cardiopulmonary bypass (CPB) system. Sixty patients scheduled for coronary artery bypass surgery were randomly assigned to either the MECC or the standard CPB system. Myocardial markers were determined by specific immunoassays 6, 12, and 24 hours after CPB initiation. Results were corrected for hemodilution. Demographics, hemodynamics, the number of anastomoses, CPB, and cross-clamp time were comparable between the groups. MECC patients demonstrated significantly lower levels of Troponin T (ng/ml) at 6, 12, and 24 hours (0.07 +/- 0.01 vs. 0.16 +/- 0.04, p < 0.005; 0.12 +/- 0.03 vs. 0.28 +/- 0.08, p < 0.008; 0.21 +/- 0.05 vs. 0.35 +/- 0.09, p < 0.03, respectively) and creatine kinase-MB (U/I) at 6 and 12 hours (22.5 +/- 1.5 vs. 40.6 +/- 3.3, p < 0.0001; 23.3 +/- 3.4 vs. 40.8 +/- 8.0, p < 0.001, respectively). Creatine kinase-MB at 24 hours tended to lower values in the MECC group but did not quite reach statistical significance. The MECC system may not only provide a less invasive solution to meet the requirements during cardiac surgery but also a more organ-preserving alternative to standard CPB.
引用
收藏
页码:32 / 35
页数:4
相关论文
共 24 条
[21]  
Vaislic C, 2003, HEART SURG FORUM, V6, P307
[22]   Mini extracorporeal circuit for coronary artery bypass grafting: initial clinical and biochemical results - A comparison with conventional and off-pump coronary artery bypass grafts concerning global oxidative stress and alveolar function [J].
van Boven, WJ ;
Gerritsen, WB ;
Waanders, FG ;
Haas, FJ ;
Aarts, LP .
PERFUSION-UK, 2004, 19 (04) :239-246
[23]   Coronary surgery without cardiotomy suction and autotransfusion reduces the postoperative systemic inflammatory response [J].
Westerberg, M ;
Bengtsson, A ;
Jeppsson, A .
ANNALS OF THORACIC SURGERY, 2004, 78 (01) :54-59
[24]   Four years' experience with a miniaturized extracorporeal circulation system and its influence on clinical outcome [J].
Wiesenack, C ;
Liebold, A ;
Philipp, A ;
Ritzka, M ;
Koppenberg, J ;
Birnbaum, DE ;
Keyl, C .
ARTIFICIAL ORGANS, 2004, 28 (12) :1082-1088