Morphometric analysis in three-dimensional intracoronary ultrasound: An in vitro and in vivo study performed with a novel system for the contour detection of lumen and plaque

被引:118
作者
vonBirgelen, C [1 ]
DiMario, C [1 ]
Li, WG [1 ]
Schuurbiers, JCH [1 ]
Slager, CJ [1 ]
deFeyter, PJ [1 ]
Roelandt, JRTC [1 ]
Serruys, PW [1 ]
机构
[1] ERASMUS UNIV ROTTERDAM, UNIV HOSP DIJKZIGT, THORAXCTR, DIV CARDIOL, NL-3000 DR ROTTERDAM, NETHERLANDS
关键词
D O I
10.1016/S0002-8703(96)90233-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Currently, automated systems for quantitative analysis by intracoronary ultrasound (ICUS) are restricted to the detection of the lumen. The aim of this study was to determine the accuracy and reproducibility of a new semiautomated contour detection method, providing off-line identification of the intimal leading edge and external contour of the vessel in three-dimensional ICUS. The system allows cross-sectional and volumetric quantification of lumen and of plaque. It applies a minimum-cost algorithm and the concept that edge points derived from previously detected longitudinal contours guide and facilitate the contour detection in the cross-sectional images. A tubular phantom with segments of various luminal dimensions was examined in vitro during five catheter pull-backs (1 mm/sec), and subsequently 20 diseased human coronary arteries were studied in vivo with 2.9F 30 MHz mechanical ultrasound catheters (200 images per 20 mm segment). The ICUS measurements of phantom lumen area and volume revealed a high correlation with the true phantom areas and volumes (r = 0.99); relative mean differences were -0.65% to 3.86% for the areas and 0.25% to 1.72% for the volumes of the various segments. Intraobserver and interobserver comparisons showed high correlations (r = 0.95 to 0.98 for area and r = 0.99 for volume) and small mean relative differences (-0.87% to 1.08%), with SD of lumen, plaque, and total vessel measurements not exceeding 7.28%, 10.81%, and 4.44% (area) and 2.66%, 2.81%, and 0.67% (volume), respectively. Thus the proposed analysis system provided accurate measurements of phantom dimensions and can be used to perform highly reproducible area and volume measurements in three-dimensional ICUS in vivo.
引用
收藏
页码:516 / 527
页数:12
相关论文
共 39 条
  • [1] Benkeser P J, 1993, J Am Soc Echocardiogr, V6, P158
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Bruining N, 1995, COMPUT CARDIOL, P633, DOI 10.1109/CIC.1995.482744
  • [4] USEFULNESS OF INTRAVASCULAR ULTRASOUND IMAGING FOR DETECTING EXPERIMENTALLY INDUCED AORTIC DISSECTION IN DOGS AND FOR DETERMINING THE EFFECTIVENESS OF ENDOLUMINAL STENTING
    CAVAYE, DM
    WHITE, RA
    LERMAN, RD
    KOPCHOK, GE
    TABBARA, MR
    CORMIER, F
    FRENCH, WJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (06) : 705 - 707
  • [5] 3-DIMENSIONAL VOLUMETRIC ULTRASOUND IMAGING OF ARTERIAL PATHOLOGY FROM 2-DIMENSIONAL INTRAVASCULAR ULTRASOUND - AN IN-VITRO STUDY
    CHANDRASEKARAN, K
    SEHGAL, CM
    HSU, TL
    YOUNG, NA
    DADAMO, AJ
    ROBB, RA
    PANDIAN, NG
    [J]. ANGIOLOGY, 1994, 45 (04) : 253 - 264
  • [6] INVITRO VALIDATION OF 3-DIMENSIONAL INTRAVASCULAR ULTRASOUND FOR THE EVALUATION OF ARTERIAL INJURY AFTER BALLOON ANGIOPLASTY
    COY, KM
    PARK, JC
    FISHBEIN, MC
    LAAS, T
    DIAMOND, GA
    ADLER, L
    MAURER, G
    SIEGEL, RJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (03) : 692 - 700
  • [7] OPTIMAL DATA-ACQUISITION FOR VOLUMETRIC INTRACORONARY ULTRASOUND
    DHAWALE, PJ
    WILSON, DL
    HODGSON, JM
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 32 (03): : 288 - 299
  • [8] Di Mario C, 1992, J Am Soc Echocardiogr, V5, P135
  • [9] DIMARIO C, 1995, BRIT HEART J, V73, P26
  • [10] QUANTITATIVE ASSESSMENT WITH INTRACORONARY ULTRASOUND OF THE MECHANISMS OF RESTENOSIS AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY AND DIRECTIONAL CORONARY ATHERECTOMY
    DIMARIO, C
    GIL, R
    CAMENZIND, E
    OZAKI, Y
    VONBIRGELEN, C
    UMANS, V
    DEJAEGERE, P
    DEFEYTER, PJ
    ROELANDT, JRTC
    SERRUYS, PW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (12) : 772 - 777