Biomechanical analysis of rotational motions after disc arthroplasty - Implications for patients with adult deformities

被引:66
作者
McAfee, Paul C. [1 ]
Cunningham, Bryan W. [1 ]
Hayes, Victor [1 ]
Sidiqi, Farhan [1 ]
Dabbah, Michael [1 ]
Sefter, John C. [1 ]
Hu, Nianbin [1 ]
Beatson, Helen [1 ]
机构
[1] St Joseph Hosp, Spine & Scoliosis Ctr, Baltimore, MD USA
关键词
total disc replacement in scoliosis; artifical disc in scoliosis; cervical stability; lumbar stability; rotational stability;
D O I
10.1097/01.brs.0000234782.89031.03
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. An anatomic and biomechanical bench-top basic scientific comparative analysis to determine the appropriateness of total disc replacement (TDR) in a lumbar spine with scolicitic tendencies. Objectives. Only limited data are currently available studying the application of disc replacement adjacent to scoliosis fusions. Theoretically, motion preservation should help delay the continuum of lumbar degeneration adjacent to scoliosis fusions and rotationally unstable lumbar segments. Summary of Background Data. As a tertiary referral center for failed TDR, we noticed an alarming number of lumbar spinal rotational iatrogenic instability patterns but none occurring in the cervical spine. It is appropriate to analyze the bench-top rotational stability of disc replacement to predict whether this new technology is feasible for a larger prospective clinical study in the treatment of degenerative scoliosis. Methods. Measurements were taken from 60 human specimens from the Hamann-Todd Osteological Collection: 1) to determine the rotational arc of influence (AOI) = the angle formed from the center of axial rotation to the outermost extent of the facet joints; and 2) to determine the relative anatomic size discrepancy between the left and right facets proportionately with the cross-sectional area of the intervertebral disc = facet/endplate ratio (FER). Biomechanical testing was performed using fresh frozen human cadaveric spines with the following conditions to determine the rotational stability: 1) intact; 2) resection of ALL, anulus, disc, and PLL simulating the preparation for a TDR; 3) a more radical anular resection; 4) entire 360 degrees anular resection; and 4) insertion of the respective unconstrained-type disc replacement. Using a 6 degrees of freedom spine simulator, unconstrained pure moments of +/- 8.0 Nm (lumbar) and +/- 3.0 Nm (cervical) were used for axial rotation with quantification of the operative level range of motion and neutral zone, with data normalized to the intact spine condition. Results. There were anatomic limitations in the lumbar spine that make it less desirable to apply unconstrained disc replacements; indeed, the spine was at risk for iatrogenic lumbar scoliosis. The anulus fibrosis, anterior longitudinal ligament, and the posterior longitudinal ligament are critical structures in preventing iatrogenic scoliosis. The lumbar facet joints are. more, posteriorly located and are smaller relative to the intervertebral disc,, compared with this association in the cervical spine;,Be, cause the facet capsular ligaments are mechanically less effective with lower tensile strength in the lumbar spine, multiple-level arthroplasty tends,to accentuate scopotic tendencies; this is independent of prosthetic design and surgical technique. Discussion. Implantation of the lumbar TDR never re stored the motion segment black to the rotational stability of the intact segment achieving a range of 120% to 140% rotational range of motion compaeed with the intact condition. This rotational instability proved to be additive as, a two-level lumbar TDR resulted in between 246% and 260% increase in rotational instability comp intact condition. Conclusion. The neutral zone of the intact cervical. spine was restored even using an unconstrained cervical TDR. The greater inherent rotational constraints cervical spine make it more amendable to stable multilevel arthroplasty compared with the lumbar spine.
引用
收藏
页码:S152 / S160
页数:9
相关论文
共 33 条
[1]
Management of symptomatic lumbar pseudarthrosis with anteroposterior fusion - A functional and radiographic outcome study [J].
Albert, TJ ;
Pinto, M ;
Denis, F .
SPINE, 2000, 25 (01) :123-129
[2]
Dislocations with intervertebral disc prosthesis: two case reports [J].
Aunoble, S ;
Donkersloot, P ;
Le Huec, JC .
EUROPEAN SPINE JOURNAL, 2004, 13 (05) :464-467
[3]
A prospective, randomized, multicenter food and drug administration Investigational device exemptions study of lumbar total disc replacement with the CHARITE™ artificial disc versus lumbar fusion Part I:: Evaluation of clinical outcomes [J].
Blumenthal, S ;
McAfee, PC ;
Guyer, RD ;
Hochschuler, SH ;
Geisler, FH ;
Holt, RT ;
Garcia, R ;
Regan, JJ ;
Ohnmeiss, DD .
SPINE, 2005, 30 (14) :1565-1575
[4]
PSEUDOARTHROSIS RATE AFTER ALLOGRAFT POSTERIOR LUMBAR INTERBODY FUSION WITH PEDICLE SCREW AND PLATE FIXATION [J].
BRANTIGAN, JW .
SPINE, 1994, 19 (11) :1271-1279
[5]
BUTTNERJANZ K, 2003, ARTIFICIAL DISK
[6]
Results of disc prosthesis after a minimum follow-up period of 2 years [J].
Cinotti, G ;
David, T ;
Postacchini, F .
SPINE, 1996, 21 (08) :995-1000
[7]
Reoperation after primary posterior instrumentation and fusion for idiopathic scoliosis - Toward defining late operative site pain of unknown cause [J].
Cook, S ;
Asher, M ;
Lai, SM ;
Shobe, J .
SPINE, 2000, 25 (04) :463-468
[8]
Biomechanical evaluation of total disc replacement arthroplasty:: An in vitro human cadaveric model [J].
Cunningham, BW ;
Gordon, JD ;
Dmitriev, AE ;
Hu, NB ;
McAfee, PC .
SPINE, 2003, 28 (20) :S110-S117
[9]
Revision of a Charite artificial disc 9.5 years in vivo to a new Charite artificial disc: case report and explant analysis [J].
David, T .
EUROPEAN SPINE JOURNAL, 2005, 14 (05) :507-511
[10]
DAVID T, 2000, 15 ANN M N AM SPIN S