A solution to remote detection of illegal electricity usage via power line communications

被引:34
作者
Cavdar, IH [1 ]
机构
[1] Karadeniz Tech Univ, Dept Elect & Elect Engn, TR-61080 Trabzon, Turkey
关键词
automatic meter reading (AMR); detector; illegal electricity usage; power line communication; power line communications (PLC) modem;
D O I
10.1109/TPWRD.2003.822540
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power line communications (PLC) presents an interesting and economical solution for automatic meter reading (AMR). If an AMR system via PLC is set in a power delivery system, a detection system for illegal electricity usage may be easily added in the existing PLC network. In the detection system, the second digitally energy meter chip is used and the value of energy is stored. The recorded energy is compared with the value at the main kilowatthour meter. In the case of the difference between two recorded energy data, an error signal is generated and transmitted via PLC network. The detector and control system is proposed. The architecture of the system and their critical components are given. The measurement results obtained from Turkey's power lines are given. This paper describes a prototype of the detector system for illegal electricity usage using the power lines. The target of this study is to discover new and possible solutions for the lack of literature concerning this problem.
引用
收藏
页码:1663 / 1667
页数:5
相关论文
共 19 条
[1]  
AKTAS Z, 1999, NEWSPAPER TURKISH DA
[2]   LOAD MANAGEMENT AND AUTOMATIC METER READING THROUGH THE USE OF POWER-LINE CARRIER [J].
ARRINGTON, RA .
ELECTRIC POWER SYSTEMS RESEARCH, 1981, 4 (02) :85-104
[3]   Performance analysis of FSK power line communications systems over the time-varying channels: Measurements and modeling [J].
Cavdar, IH .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (01) :111-117
[4]  
ESPOSITO A, 1990, ELETTROTECNICA, V77, P1055
[5]   Message delay for a priority-based automatic meter reading network [J].
Frigui, I ;
Stone, R ;
Alfa, AS .
COMPUTER COMMUNICATIONS, 1997, 20 (01) :38-47
[6]   AN OPTIMIZED GATEWAY CONTROLLER FOR HA SYSTEM AND AUTOMATIC METER READING SYSTEM [J].
HONDA, Y ;
KUSHIRO, N ;
MARUYAMA, K ;
ASHIZAWA, T .
IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 1991, 37 (03) :388-394
[7]   Experimenting remote kilowatthour meter reading through low-voltage power lines at dense housing estates [J].
Lim, TY ;
Chan, TW .
IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (03) :708-711
[8]   DESIGN CONSIDERATIONS FOR IMPLEMENTATION OF LARGE-SCALE AUTOMATIC METER READING SYSTEMS [J].
MAK, S ;
RADFORD, D .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (01) :97-103
[9]  
MIURA N, 1990, P I EL ENG C, V137, P25
[10]   Communications field trials for total utility metering [J].
Newbury, J .