Platelet morphology in patients with mechanical circulatory support

被引:16
作者
Dewald, O [1 ]
Fischlein, T [1 ]
Vetter, HO [1 ]
Schmitz, C [1 ]
Godje, O [1 ]
Gohring, P [1 ]
Reichart, R [1 ]
机构
[1] UNIV MUNICH,DEPT CARDIAC SURG,GROSSHADERN MED CTR,MUNICH,GERMANY
关键词
platelet morphology; mechanical circulatory support; scanning electron microscopy;
D O I
10.1016/S1010-7940(97)00151-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Mechanical circulatory support is a therapy for patients with end stage cardiac insufficiency. The thromboembolic events are feared complications during support, due to the surface thrombogenicity of the implanted device. Activated blood platelets play a major role in this context. Consequently the platelet morphology of patients was investigated. Methods: Platelets of eight patients were observed by means of scanning electron microscopy during the period of support with the Novacor left ventricular assist system N100. Blood was collected preoperatively and daily during the first week as well as weekly during the first 3 months. Samples were fixed with cacodylic-acid buffered glutaraldehyde. Platelet alterations were classified as non-activated, activated and aggregated, based on the so-called 'shape change' morphology. In addition, blood coagulation parameters were evaluated (e.g. activated partial thromboplastin time, prothrombin time, antithrombin III). Results: Preoperatively, 15.0 +/- 4.6% (overall mean values) of activated platelets were found. Within the first postoperative week, the mean level of activated platelets increased to 32.5 +/- 8.0% (P < 0.05). Comparing short- (< 30 days; n = 4) vs. long-period (> 30 days, n = 4) support, a significant difference of activated platelets was evaluated (24.3 +/- 3.3% vs. 34.8 +/- 3.4%, P = 0.004). A correlation was found between the values of activated clotting time and activated platelets. Specific platelet deformations and damages appeared during support, which could not be found preoperatively. Conclusions: The platelet morphology showed alterations in all patients probably most strongly induced by the surface activation of the implanted device. These observations should be taken into consideration in management of postoperative anticoagulation therapy. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:634 / 641
页数:8
相关论文
共 24 条
[11]   THROMBOEMBOLIC COMPLICATIONS OF THE JARVIK-7 TOTAL ARTIFICIAL-HEART - CASE-REPORT [J].
LEVINSON, MM ;
SMITH, RG ;
CORK, RC ;
GALLO, J ;
EMERY, RW ;
ICENOGLE, TB ;
OTT, RA ;
BURNS, GL ;
COPELAND, JG .
ARTIFICIAL ORGANS, 1986, 10 (03) :236-244
[12]   Hemostasis Changes During Cardiopulmonary Bypass Surgery (Reprinted from Semin Thromb Hemost, vol 11, pg 281-292, 1985) [J].
Mammen, Eberhard F. ;
Koets, Mark H. ;
Washington, Bruce C. ;
Wolk, Larry W. ;
Brown, Janet M. ;
Burdick, Michael ;
Selik, Nancy R. ;
Wilson, Robert F. .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2008, 34 (08) :A12-A21
[13]  
MEHTA SM, 1995, J HEART LUNG TRANSPL, V14, P585
[14]  
MOOREHEAD MT, 1984, ANESTH ANALG, V63, P394
[15]  
MORGENSTERN E, 1977, CYTOBIOLOGIE, V15, P233
[16]   Clinical relevance of intracranial microembolic signals in patients with left ventricular assist devices - A prospective study [J].
Nabavi, DG ;
Georgiadis, D ;
Mumme, T ;
Schmid, C ;
Mackay, TG ;
Scheld, HH ;
Ringelstein, EB .
STROKE, 1996, 27 (05) :891-896
[17]  
Salih V, 1993, Am J Cardiovasc Pathol, V4, P317
[18]  
SATO N, 1993, J THORAC CARDIOV SUR, V106, P520
[19]  
SLACK SM, 1993, THROMB HAEMOSTASIS, V70, P129
[20]  
SMITH CM, 1990, J LAB CLIN MED, V115, P729