Automated quantitative determination of the new renin inhibitor CGP 60536 by high-performance liquid chromatography

被引:13
作者
Lefèvre, G
Gauron, S
机构
[1] Novartis Pharma AG, CH-4002 Basel, Switzerland
[2] Novartis Pharma SA, Rueil Malmaison, France
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2000年 / 738卷 / 01期
关键词
renin inhibitor; CGP; 60536;
D O I
10.1016/S0378-4347(99)00509-5
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
A fully automated high-performance liquid chromatography method with fluorescence detection for the determination of the renin inhibitor CGP 60536 in animal and human plasma and urine has been developed and validated. After addition of an internal standard, the compounds were automatically extracted from 400 mu l of plasma or urine with methyl alcohol-acetic acid (99:1, v/v) on 100-mg Bond-Elut CN cartridges using the Gilson ASPEC system. The on-line chromatographic separation was performed on a LiChrospher 100 RP8 5-mu m particle size packed analytical column (25x0.4 cm I.D.). The mobile phase consisted of acetonitrile-0.01 M potassium dihydrogenphosphate (65:35, v/v) at a flow-rate of 0.8 ml/min. The analytes were detected using a fluorescence detector at excitation and emission wavelengths of 280 and 330 nm, respectively. The limit of quantitation was established at 4.5 ng/ml in plasma (accuracy 106% and precision 1%), and 9.0 ng/ml in urine (accuracy 101% and precision 13%). The method was applied to the investigation of the pharmacokinetics of CGP 60536. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:129 / 136
页数:8
相关论文
共 15 条
[2]
RENIN INHIBITORS [J].
GREENLEE, WJ .
MEDICINAL RESEARCH REVIEWS, 1990, 10 (02) :173-236
[3]
BIOLOGICAL SAMPLE PREPARATION AND DATA REDUCTION CONCEPTS IN PHARMACEUTICAL ANALYSIS [J].
JOHNSON, EL ;
REYNOLDS, DL ;
WRIGHT, DS ;
PACHLA, LA .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1988, 26 (08) :372-379
[4]
LUNDJOHANSEN P, 1988, HDB HYPERTENSION, V1, P41
[5]
LUTHER RR, 1989, DRUG RES, V39, P1
[6]
MAIBAUM J, 1998, 15 EFMC INT S MED CH
[7]
High-performance liquid chromatography of the aromatase inhibitor, letrozole, and its metabolite in biological fluids with automated liquid-solid extraction and fluorescence detection [J].
Marfil, F ;
Pineau, V ;
Sioufi, A ;
Godbillon, J .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 683 (02) :251-258
[8]
NICKLAS JM, 1992, NEW ENGL J MED, V327, P685
[9]
CLINICAL PHARMACOKINETICS AND EFFICACY OF RENIN INHIBITORS [J].
RONGEN, GA ;
LENDERS, JWM ;
SMITS, P ;
THIEN, T .
CLINICAL PHARMACOKINETICS, 1995, 29 (01) :6-14
[10]
AUTOMATED MICROANALYSIS OF OXCARBAZEPINE AND ITS MONOHYDROXY AND TRANSDIOL METABOLITES IN PLASMA BY LIQUID-CHROMATOGRAPHY [J].
ROUAN, MC ;
DECHERF, M ;
LECLANCHE, V ;
LECAILLON, JB ;
GODBILLON, J .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 658 (01) :167-172