Thorax: Low-dose contrast-enhanced three-dimensional MR angiography with subsecond temporal resolution - Initial results

被引:64
作者
Finn, JP
Baskaran, V
Carr, JC
McCarthy, RM
Pereles, FS
Kroeker, R
Laub, GA
机构
[1] Northwestern Univ, Sch Med, Dept Radiol, Chicago, IL 60611 USA
[2] Siemens Med Syst Inc, Chicago, IL USA
关键词
magnetic resonance (MR); rapid imaging; vascular studies;
D O I
10.1148/radiol.2243010984
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of the study was to im plement a three-dimensional (3D) magnetic resonance (MR) angiographic technique with acquisition times on the order of 800 msec with use of a spoiled gradient-echo pulse sequence (repetition time, 1.60 msec; echo time, 0.65 msec) and bolus intravenous injection of contrast material doses as small as 6 mL. High-spatial-resolution conventional MR angiography performed with 30 mL of gadopentetate dimeglumine was the reference standard. As implemented, subsecond 30 MR angiography allowed temporal sampling that was, rapid enough to depict short-lived processes, as illustrated in patients with shunts and dissections. With small contrast material doses and subsecond frame rates, it is also possible to, measure pulmonary arteriovenous circulation times with this 3D MR angiographic technique. (C) RSNA, 2002.
引用
收藏
页码:896 / 904
页数:9
相关论文
共 41 条
[1]  
BASKARAN V, 2001, P 9 M INT SOC MAGN R, V3, P1935
[2]   MOTION ARTIFACT SIMULATING AORTIC DISSECTION ON CT [J].
BURNS, MA ;
MOLINA, PL ;
GUTIERREZ, FR ;
SAGEL, SS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (03) :465-467
[3]   GADOLINIUM-ENHANCED MR ANGIOGRAPHY [J].
CREASY, JL ;
PRICE, RR ;
PRESBREY, T ;
GOINS, D ;
PARTAIN, CL ;
KESSLER, RM .
RADIOLOGY, 1990, 175 (01) :280-283
[4]   High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: A prospective comparison with digital subtraction angiography [J].
Fain, SB ;
King, BF ;
Breen, JF ;
Kruger, DG ;
Riederer, SJ .
RADIOLOGY, 2001, 218 (02) :481-490
[5]  
Fattori R, 1999, J MAGN RESON IMAGING, V10, P741, DOI 10.1002/(SICI)1522-2586(199911)10:5<741::AID-JMRI19>3.3.CO
[6]  
2-0
[7]   Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography [J].
Foo, TKF ;
Saranathan, M ;
Prince, MR ;
Chenevert, TL .
RADIOLOGY, 1997, 203 (01) :275-280
[8]   RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY [J].
GALANSKI, M ;
PROKOP, M ;
CHAVAN, A ;
SCHAEFER, CM ;
JANDELEIT, K ;
NISCHELSKY, JE .
RADIOLOGY, 1993, 189 (01) :185-192
[9]   Imaging of aortic aneurysms and dissection: CT and MRI [J].
Hartnell, GG .
JOURNAL OF THORACIC IMAGING, 2001, 16 (01) :35-46
[10]   Time-resolved projection angiography after bolus injection of contrast agent [J].
Hennig, J ;
Scheffler, K ;
Laubenberger, J ;
Strecker, R .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) :341-345