Thorax: Low-dose contrast-enhanced three-dimensional MR angiography with subsecond temporal resolution - Initial results

被引:64
作者
Finn, JP
Baskaran, V
Carr, JC
McCarthy, RM
Pereles, FS
Kroeker, R
Laub, GA
机构
[1] Northwestern Univ, Sch Med, Dept Radiol, Chicago, IL 60611 USA
[2] Siemens Med Syst Inc, Chicago, IL USA
关键词
magnetic resonance (MR); rapid imaging; vascular studies;
D O I
10.1148/radiol.2243010984
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of the study was to im plement a three-dimensional (3D) magnetic resonance (MR) angiographic technique with acquisition times on the order of 800 msec with use of a spoiled gradient-echo pulse sequence (repetition time, 1.60 msec; echo time, 0.65 msec) and bolus intravenous injection of contrast material doses as small as 6 mL. High-spatial-resolution conventional MR angiography performed with 30 mL of gadopentetate dimeglumine was the reference standard. As implemented, subsecond 30 MR angiography allowed temporal sampling that was, rapid enough to depict short-lived processes, as illustrated in patients with shunts and dissections. With small contrast material doses and subsecond frame rates, it is also possible to, measure pulmonary arteriovenous circulation times with this 3D MR angiographic technique. (C) RSNA, 2002.
引用
收藏
页码:896 / 904
页数:9
相关论文
共 41 条
[31]  
Scarabino T, 1999, J NEURORADIOLOGY, V26, P87
[32]  
Shetty AN, 2000, J MAGN RESON IMAGING, V12, P912, DOI 10.1002/1522-2586(200012)12:6<912::AID-JMRI15>3.3.CO
[33]  
2-1
[34]   PULMONARY CIRCULATION TIME - COMPARISON OF MEAN, MEDIAN, PEAK, AND ONSET (APPEARANCE) VALUES USING INDOCYANINE GREEN AND 1ST-TRANSIT RADIONUCLIDE TECHNIQUES [J].
SLUTSKY, RA ;
BHARGAVA, V ;
HIGGINS, CB .
AMERICAN HEART JOURNAL, 1983, 106 (01) :41-45
[35]   ANALYSIS OF THE PULMONARY CIRCULATION USING DIGITAL INTRAVENOUS ANGIOGRAPHY [J].
SLUTSKY, RA ;
HIGGINS, CB .
RADIOLOGY, 1983, 146 (01) :219-221
[36]   A COMPARISON OF PEAK-TO-PEAK PULMONARY TRANSIT-TIME DETERMINED BY DIGITAL INTRAVENOUS ANGIOGRAPHY WITH STANDARD DYE-DILUTION TECHNIQUES IN ANESTHETIZED DOGS [J].
SLUTSKY, RA ;
CAREY, PH ;
BHARGAVA, V ;
HIGGINS, CB .
INVESTIGATIVE RADIOLOGY, 1982, 17 (04) :362-366
[37]  
Strecker R, 2000, MAGNET RESON MED, V43, P303, DOI 10.1002/(SICI)1522-2594(200002)43:2<303::AID-MRM19>3.0.CO
[38]  
2-R
[39]   Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction [J].
Wang, Y ;
Johnston, DL ;
Breen, JF ;
Huston, J ;
Jack, CR ;
Julsrud, PR ;
Kiely, MJ ;
King, BF ;
Riederer, SL ;
Ehman, RL .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :551-556
[40]   Breath-hold three-dimensional contrast-enhanced coronary MR angiography: Motion-matched k-space sampling for reducing cardiac motion effects [J].
Wang, Y ;
Winchester, PA ;
Yu, L ;
Watts, R ;
Ding, GL ;
Lee, HM ;
Bergman, GW .
RADIOLOGY, 2000, 215 (02) :600-607