Quantitation of tylosin in swine tissues by liquid chromatography combined with electrospray ionization mass spectrometry

被引:39
作者
Cherlet, M [1 ]
De Baere, S [1 ]
Croubels, S [1 ]
De Backer, P [1 ]
机构
[1] Univ Ghent, Fac Vet Med, Dept Pharmacol Toxicol & Pharm, B-9820 Merelbeke, Belgium
关键词
tylosin A solid-phase clean-up; LC-ESI-MS/MS;
D O I
10.1016/S0003-2670(02)00873-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tylosin is a medium-spectrum macrolide antibiotic used exclusively in veterinary medicine for the treatment of a wide range of infections. The purpose of this study was to develop and validate a method to determine tylosin A residues in edible tissues of swine. Extraction of tylosin A from the tissues was performed using liquid extraction with methanol, followed by a solid-phase clean-up procedure on an SCX strong cation-exchange column. Spiramycin was used as the internal standard. After drying of the eluate, the residue was redissolved and further analyzed by reversed phase liquid chromatography-electrospray ionisation-mass spectrometry/mass spectrometry (LC-ESI-MS[MS). Chromatographic separation of the internal standard spiramycin I and tylosin A was achieved on a Nucleosil (5 mum) column using a mixture of 0.01 M ammonium acetate pH 3.5 in water and acetonitrile as the mobile phase. The tylosin A component could be identified from MS/MS detection, and subsequently quantified. The method has been validated according to the requirements of the EC at the maximum residue limit (MRL), 100 ng tylosin A/g for muscle, skin + fat, kidney and liver), half the MRL and double the MRL levels. Calibration graphs were prepared for all tissues and good linearity was achieved over the concentration ranges tested (r > 0.99 and goodness of fit <10%). Limits of quantification of 5.0 ng g(-1) were obtained for the determination of tylosin A in all tissues, which is well below half the MRL. Limits of detection ranged between 0.2 and 0.8ngg(-1) for the various tissues. The within-day and between-day precisions and the accuracy fell within the ranges specified. The method has been successfully used for the quantitation of tylosin A in tissue samples of swine medicated with tylosin via intramuscular injection. (C) 2002 Elsevier Science B.V. All fights reserved.
引用
收藏
页码:167 / 175
页数:9
相关论文
共 20 条
  • [1] CHAN W, 1994, J AOAC INT, V77, P331
  • [2] Quantitative analysis of levamisole in porcine tissues by high-performance liquid chromatography combined with atmospheric pressure chemical ionization mass spectrometry
    Cherlet, M
    De Baere, S
    Croubels, S
    De Backer, P
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 742 (02): : 283 - 293
  • [3] De Liguoro M, 1998, ANALYST, V123, P1279, DOI 10.1039/a708004b
  • [4] Delepine B, 1996, J AOAC INT, V79, P397
  • [5] IDENTIFICATION OF TYLOSIN IN BOVINE MUSCLE AT THE MAXIMUM RESIDUE LIMIT LEVEL BY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY, USING A PARTICLE-BEAM INTERFACE
    DELEPINE, B
    HURTAUD, D
    SANDERS, P
    [J]. ANALYST, 1994, 119 (12) : 2717 - 2721
  • [6] Confirmatory method for macrolide residues in bovine tissues by micro-liquid chromatography-tandem mass spectrometry
    Draisci, R
    Palleschi, L
    Ferretti, E
    Achene, L
    Cecilia, A
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (01) : 97 - 104
  • [7] Identification and quantification of five macrolide antibiotics in several tissues, eggs and milk by liquid chromatography-electrospray tandem mass spectrometry
    Dubois, M
    Fluchard, D
    Sior, E
    Delahaut, P
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2001, 753 (02): : 189 - 202
  • [8] Dudriková E, 1999, J AOAC INT, V82, P1303
  • [9] EDDER P, 2000, RESIDUES VET DRUGS F, P418
  • [10] HEITZMAN RJ, 1992, 14126EN EUR COMM EC