Label free novel electrical detection using micromachined PZT monolithic thin film cantilever for the detection of C-reactive protein

被引:111
作者
Lee, JH
Yoon, KH
Hwang, KS
Park, J
Ahn, S
Kim, TS
机构
[1] KIST, Microsyst Res Ctr, Seoul 136791, South Korea
[2] Yonsei Univ, Dept Ceram Engn, Seoul 120749, South Korea
[3] Solco Biomed Co, Kyonggi Do 451852, South Korea
[4] Seoul Natl Univ, CTP, Seoul, South Korea
关键词
nanomechanical biosensor; cantilever; PZT film; CRP; resonant frequency shift;
D O I
10.1016/j.bios.2004.01.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper, we report the novel electrical measurement for the label-free detection of C-reactive protein (CRP) using resonant frequency shift in the monolithic thin film cantilever of micromachined Pb(Zr0.52Ti0.48)O-3 (PZT) which was fabricated with the composition of SiO2/Ta/Pt/PZT/Pt/SiO2 on silicon nitride (SiNx) supporting layer for the dual purpose of electrical self-excitation and sensing. The specific binding characteristics of CRP antigen to its antibody, which is immobilized with Calixcrown SAMs on An surface deposited on microcantilever, is determined in high sensitivity to the nanogram level per milliliter by measuring the resonant frequency shift. The nanomechanical PZT cantilever turns out a robust platform for the highly specific antigen-antibody interaction and provides with the novel tool for qualification and quantification of biomolecules without any sample labeling and bulky optical apparatus. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:269 / 275
页数:7
相关论文
共 24 条
[1]   Development of nanomechanical biosensors for detection of the pesticide DDT [J].
Alvarez, M ;
Calle, A ;
Tamayo, J ;
Lechuga, LM ;
Abad, A ;
Montoya, A .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :649-653
[2]   THE ACUTE-PHASE RESPONSE [J].
BAUMANN, H ;
GAULDIE, J .
IMMUNOLOGY TODAY, 1994, 15 (02) :74-80
[3]   Surface stress in the self-assembly of alkanethiols on gold probed by a force microscopy technique [J].
Berger, R ;
Delamarche, E ;
Lang, HP ;
Gerber, C ;
Gimzewski, JK ;
Meyer, E ;
Guntherodt, HJ .
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1998, 66 (Suppl 1) :S55-S59
[4]   Surface stress in the self-assembly of alkanethiols on gold [J].
Berger, R ;
Delamarche, E ;
Lang, HP ;
Gerber, C ;
Gimzewski, JK ;
Meyer, E ;
Guntherodt, HJ .
SCIENCE, 1997, 276 (5321) :2021-2024
[5]   ADSORPTION-INDUCED SURFACE STRESS AND ITS EFFECTS ON RESONANCE FREQUENCY OF MICROCANTILEVERS [J].
CHEN, GY ;
THUNDAT, T ;
WACHTER, EA ;
WARMACK, RJ .
JOURNAL OF APPLIED PHYSICS, 1995, 77 (08) :3618-3622
[6]   Determination of adsorption-induced variation in the spring constant of a microcantilever [J].
Cherian, S ;
Thundat, T .
APPLIED PHYSICS LETTERS, 2002, 80 (12) :2219-2221
[7]   Translating biomolecular recognition into nanomechanics [J].
Fritz, J ;
Baller, MK ;
Lang, HP ;
Rothuizen, H ;
Vettiger, P ;
Meyer, E ;
Güntherodt, HJ ;
Gerber, C ;
Gimzewski, JK .
SCIENCE, 2000, 288 (5464) :316-318
[8]   Characterisation of an antibody coated microcantilever as a potential immuno-based biosensor [J].
Grogan, C ;
Raiteri, R ;
O'Connor, GM ;
Glynn, TJ ;
Cunningham, V ;
Kane, M ;
Charlton, M ;
Leech, D .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (03) :201-207
[9]   Mechanical resonant immunospecific biological detector [J].
Ilic, B ;
Czaplewski, D ;
Craighead, HG ;
Neuzil, P ;
Campagnolo, C ;
Batt, C .
APPLIED PHYSICS LETTERS, 2000, 77 (03) :450-452
[10]  
IYER SRS, 1975, ADSORPTION INTERFACE