On the study of the credit-weighting scale in a building environmental assessment scheme

被引:54
作者
Lee, WL [1 ]
Chau, CK [1 ]
Yik, FWH [1 ]
Burnett, J [1 ]
Tse, MS [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
environmental assessment method; weighting scale; carbon dioxide emission; least cost planning;
D O I
10.1016/S0360-1323(02)00006-9
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A major strength of the voluntary building environmental assessment method is to encourage good environmental practice beyond the current industry practice. For a successful voluntary scheme, the credit scale must be attractive to investors and performance-based criteria should be used. However, most of the current schemes use a combination of prescriptive and performance-based criteria, and credits are allocated using subjective judgement, irrespective of cost and practical implications of attaining improved performances. This is pointed to the need to establish an incentive-crediting scheme, which is oriented towards performance-based scales having credits linked to cost and performance. In formulating the incentive-crediting scheme, the cost effectiveness of different energy-saving level in a base building is investigated under the premise that the investors would pursue a strategy in the most cost-effective manner. This paper presents a conceptual framework for policy makers to formulate an incentive-crediting scale for accrediting criteria within the greenhouse gas objectives of a building environmental assessment scheme in Hong Kong, aiming to attract participation of the profit-maximising investors. Establishment of an incentive-crediting scale starts from developing a carbon dioxide abatement curve for greenhouse gas emission. This is subsequently followed by dividing the maximum energy-saving potential into ten equal energy reduction intervals. The incentive-crediting scheme is formulated on a basis that proportionally more credits would be rewarded for diminishing investment return of consecutive reduction levels in a base building. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1385 / 1396
页数:12
相关论文
共 49 条
[31]  
LEE WL, 2001, UNPUB ENERGY
[32]  
Levin H, 1997, P 2 INT C BUILD ENV, P3
[33]  
MEEKS CB, 1996, INT INT C 7 P MARCH
[34]   CONSTRUCTING CO2 REDUCTION COST CURVES - THE CASE OF DENMARK [J].
MORTHORST, PE .
ENERGY POLICY, 1994, 22 (11) :964-970
[35]   Carbon dioxide savings in the commercial building sector [J].
Mortimer, ND ;
Ashley, A ;
Moody, CAC ;
Rix, JHR ;
Moss, SA .
ENERGY POLICY, 1998, 26 (08) :615-624
[36]  
PALADINO T, 1999, AIA C CHATT TN US OC
[37]  
Prior J., 1993, BUILDING RES ESTABLI
[38]  
*SRCI, 1997, EST EN END US DAT HO
[39]  
THOMAS JR, 1992, MICROECONOMIC REFORM
[40]  
TODD J, 1998, P GREEN BUILD CHALLE, V1, P330