PTV-LV-GC/MS/MS as screening and complementary method to HRMS for the monitoring of dioxin levels in food and feed

被引:51
作者
Eppe, G [1 ]
Focant, JF [1 ]
Pirard, C [1 ]
De Pauw, E [1 ]
机构
[1] Univ Liege, CART, Mass Spectrometry Lab, B-4000 Cointe Ougree, Belgium
关键词
programmable temperature vaporization injector; large volume injection; tandem mass spectrometry; polychlorinated dibenzo-p-dioxin; dibenzofuran; food; feed;
D O I
10.1016/j.talanta.2004.05.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recent developments in trapping efficiency inside ion trap mass spectrometer permitted to lower instrument detection limit (IDL). An IDL of 200 fg mul(-1) injected with a signal-to-noise ratio of 5:1 for tetrachlorodibenzo-p-dioxin (TCDD) was obtained by gas chromatography coupled to a quadrupole ion storage mass spectrometer in tandem mode (GC/MS/MS). Coupling large volume programmable temperature vaporizer (PTV-LV) injection to GC/MS/MS provides an alternative and complementary method to classical splitless-GC injection connected to high-resolution mass spectrometry (splitless-GC/HRMS) method for dioxin monitoring in food and feed. An injection volume of 10 mul was found to be the best compromise between the sensitivity requirements and the robustness required for a high throughput method. PTV-LV-GC/MS/MS and Splitless-GC/HRMS were compared by performing analysis on five different matrices such as beef fat, yolk eggs, milk powder, animal feed and serum samples covering a concentration range of two orders of magnitude (i.e. 0.2-25 ng WHO-TEQ kg(-1)). An analysis of variance (ANOVA) was carried out. Fisher tests pointed out that the method effect for all the 2,3,7,8 congeners was not significant, indicating that the null hypothesis (H-0: mu(1) = mu(2) = ... = mu(n)) was not rejected. Moreover, the interaction effects between methods and matrices were not significant for most of the 2,3,7,8 congeners. However, three congeners (2,3,7,8-TCDF; 1,2,3,4,7,8-HxCDD and I,2,3,4,6,7,8-HpCDD) were characterized by P-values lower than the significance level (alpha = 0.05). In toxic equivalence (TEQ), the study showed that no significant bias was observed between the two methods. Consequently, PTV-LV-GC/MS/MS is an attractive technique and can be used as a cost effective complementary method to HRMS for dioxin levels monitoring in food and feed. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1135 / 1146
页数:12
相关论文
共 24 条
[1]  
*AFNOR, 1994, NFX03110 AFNOR
[2]  
[Anonymous], 1994, 1613 EPA
[3]   Determination of polybrominated diphenyl ethers and polychlorinated biphenyls in human adipose tissue by large-volume injection - Narrow-bore capillary gas chromatography/electron impact low-resolution mass spectrometry [J].
Covaci, A ;
de Boer, J ;
Ryan, JJ ;
Voorspoels, S ;
Schepens, P .
ANALYTICAL CHEMISTRY, 2002, 74 (04) :790-798
[4]  
Eppe G, 2001, ORGANOHALOGEN COMP, V50, P186
[5]  
FEINBERG M, 1996, VALIDATION METHODES
[6]   Fast automated extraction and clean-up of biological fluids for polychlorinated dibenzo-p-dioxins, dibenzofurans and coplanar polychlorinated biphenyls analysis [J].
Focant, JF ;
De Pauw, E .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 776 (02) :199-212
[7]   Optimisation and use of tandem-in-time mass spectrometry in comparison with immunoassay and HRGC/HRMS for PCDD/F screening [J].
Focant, JF ;
Eppe, G ;
De Pauw, E .
CHEMOSPHERE, 2001, 43 (4-7) :417-424
[8]   Fast clean-up for polychlorinated dibenzo-p-dioxins, dibenzofurans and coplanar polychlorinated biphenyls analysis of high-fat-content biological samples [J].
Focant, JF ;
Eppe, G ;
Pirard, C ;
De Pauw, E .
JOURNAL OF CHROMATOGRAPHY A, 2001, 925 (1-2) :207-221
[10]   Tandem-in-time mass spectrometry method for the sub-parts-per-trillion determination of 2,3,7,8-chlorine-substituted dibenro-p-dioxins and -furans in high-fat foods [J].
Hayward, DG ;
Hooper, K ;
Andrzejewski, D .
ANALYTICAL CHEMISTRY, 1999, 71 (01) :212-220