Fast automated extraction and clean-up of biological fluids for polychlorinated dibenzo-p-dioxins, dibenzofurans and coplanar polychlorinated biphenyls analysis

被引:40
作者
Focant, JF [1 ]
De Pauw, E [1 ]
机构
[1] Univ Liege, Dioxin Lab, Mass Spectrometry Lab, B-4000 Liege, Belgium
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 776卷 / 02期
关键词
polychlorinated dibenzo-p-dioxins; polychlorinated dibenzofurans; polychlorinated biphenyls;
D O I
10.1016/S1570-0232(02)00343-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fast automated extraction and clean-up procedure for low-level analysis of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and coplanar polychlorinated biphenyls (cPCBs) in biological fluids is presented. Online extraction of prepared fluids is carried out using disposable octadecyl bonded (C-18) solid-phase extraction columns. Extracts are then cleaned up through disposable multi-layer silica (acidic, basic and neutral) and dispersed PX-21 carbon columns. This new methodology is compared with classical Soxhlet extraction and manual solid-phase extraction in terms of repeatability, reproducibility, accuracy and recovery rates for reference and certified materials. Robustness is evaluated on different matrices, such as cow's milk, breast milk and human serum. As a consequence of the reduced number of reusable glassware used, as well as lowering of solvent consumption, recorded blank levels are decreased in favor of limits of detection (LODs). Total analysis time and cost are further reduced using simultaneous sample preparation units and the sample throughput is increased compared to classical methods. As a result, this new approach appears to be suitable for the fast sample preparation often required for such fluids in case of emergency foodstuffs analysis or during large epidemiological studies. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:199 / 212
页数:14
相关论文
共 37 条
[1]   Evaluation of a new automated cleanup system for the analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans in environmental samples [J].
Abad, E ;
Sauló, J ;
Caixach, J ;
Rivera, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 893 (02) :383-391
[2]  
[Anonymous], OGANOHALOGEN COMPOUN
[3]  
[Anonymous], 1994, ORGANOHALOGEN COMP
[4]   An improved analysis for chlorinated pesticides and polychlorinated biphenyls (PCBs) in human and bovine sera using solid-phase extraction [J].
Brock, JW ;
Burse, VW ;
Ashley, DL ;
Najam, AR ;
Green, VE ;
Korver, MP ;
Powell, MK ;
Hodge, CC ;
Needham, LL .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1996, 20 (07) :528-536
[5]   Selected analytical methods used at the Centers for Disease Control and Prevention for measuring environmental pollutants in serum [J].
Burse, VW ;
Patterson, DG ;
Brock, JW ;
Needham, LL .
TOXICOLOGY AND INDUSTRIAL HEALTH, 1996, 12 (3-4) :481-498
[6]   REVIEW OF THE DIOXIN PROBLEM - MASS-SPECTROMETRIC ANALYSES OF TETRACHLORODIOXINS IN ENVIRONMENTAL-SAMPLES [J].
CAIRNS, T ;
FISHBEIN, L ;
MITCHUM, RK .
BIOMEDICAL MASS SPECTROMETRY, 1980, 7 (11-1) :484-492
[7]   Recent extraction techniques for solid matrices-supercritical fluid extraction, pressurized fluid extraction and microwave-assisted extraction: their potential and pitfalls [J].
Camel, V .
ANALYST, 2001, 126 (07) :1182-1193
[8]   BIOACCUMULATION OF PCDDS AND PCDFS IN FOOD ANIMALS .3. A RAPID CLEANUP OF BIOLOGICAL-MATERIALS USING REVERSE PHASE ADSORBENT COLUMNS [J].
CHANG, RR ;
JARMAN, WM ;
KING, CC ;
ESPERANZA, CC ;
STEPHENS, RD .
CHEMOSPHERE, 1990, 20 (7-9) :881-886
[9]  
Covaci A., 2001, ORGANOHALOGEN COMP, V52, P172
[10]   Extraction of organic pollutants from environmental matrices: selection of extraction technique [J].
Dean, JR ;
Xiong, GH .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (09) :553-564