Selected analytical methods used at the Centers for Disease Control and Prevention for measuring environmental pollutants in serum

被引:11
作者
Burse, VW
Patterson, DG
Brock, JW
Needham, LL
机构
[1] Division of Environmental Health Laboratory Sciences, National Center for Environmental Health Centers for Disease Control and Prevention, U.S. Department of Health and Human Services, Atlanta
关键词
blood serum; environmental pollutants; solid-phase extraction; two-dimensional chromatography;
D O I
10.1177/074823379601200320
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Blood serum is one of the more viable matrices used in assessing exposure to persistent environmental contaminants or their metabolites, especially those that are lipophilic. Analytic methods currently in use for this matrix usually involve liquid/liquid extraction followed by adsorption chromatography as a cleanup step, and low- or high-resolution gas chromatography with either electron-capture or mass spectrometric detection. The traditional analytic methods are labor intensive, have low sample throughput, and use excessive amounts of solvents and reagents. Two analytic approaches that address the requirements of modern laboratories more effectively are: I) solid-phase extraction (SPE), used to analyze serum for several classes of compounds of environmental concern (e.g., polychlorinated biphenyls [PCBs], persistent pesticides, dioxins, furans, and coplanar polychlorinated biphenyls [CPCBs]), and 2) fast chromatography with a two-dimensional gas chromatographic system, which can be used in the determinative step for these types of analytes.
引用
收藏
页码:481 / 498
页数:18
相关论文
共 22 条
[1]  
[Anonymous], 1994, ORGANOHALOGEN COMP
[2]   ANALYSIS OF POLYCHLORINATED-BIPHENYLS (PCB) BY GLASS-CAPILLARY GAS-CHROMATOGRAPHY - COMPOSITION OF TECHNICAL AROCLOR-PCB AND CLOPHEN-PCB MIXTURES [J].
BALLSCHMITER, K ;
ZELL, M .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1980, 302 (01) :20-31
[3]   POTENTIAL COMPOUNDS FOR MONITORING METHOD PERFORMANCE IN THE DETERMINATION OF SELECTED ORGANOCHLORINE PESTICIDES AND POLYCHLORINATED-BIPHENYLS IN HUMAN SERUM [J].
BURSE, VW ;
MCCLURE, PC ;
KORVER, MP ;
HEAD, SL ;
NEEDHAM, LL .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1990, 14 (03) :143-145
[4]  
BURSE VW, 1989, J ASSOC OFF ANA CHEM, V72, P649
[5]  
BURSE VW, 1990, J ANAL TOXICOL, V14, P137, DOI 10.1093/jat/14.3.137
[6]  
CUNISS P, 1995, AOAC OFFICIAL METHOD, P19
[7]  
DALE WILLIAM E., 1966, LIFE SCI, V5, P47, DOI 10.1016/0024-3205(66)90186-X
[8]   SCREENING METHOD FOR AROCLOR-1254 IN WHOLE-BLOOD [J].
HEE, SSQ ;
WARD, JA ;
TABOR, MW ;
SUSKIND, RR .
ANALYTICAL CHEMISTRY, 1983, 55 (01) :157-160
[9]   AUTOMATED APPARATUS FOR THE EXTRACTION AND ENRICHMENT OF 2,3,7,8-TETRACHLORODIBENZO-PARA-DIOXIN IN HUMAN ADIPOSE-TISSUE [J].
LAPEZA, CR ;
PATTERSON, DG ;
LIDDLE, JA .
ANALYTICAL CHEMISTRY, 1986, 58 (04) :713-716
[10]   COMPREHENSIVE 2-DIMENSIONAL GAS-CHROMATOGRAPHY FOR THE FAST SEPARATION AND DETERMINATION OF PESTICIDES EXTRACTED FROM HUMAN SERUM [J].
LIU, ZY ;
SIRIMANNE, SR ;
PATTERSON, DG ;
NEEDHAM, LL ;
PHILLIPS, JB .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3086-3092