Cavotricuspid isthmus angiography predicts atrial flutter ablation efficacy in 281 patients randomized between 8 mm- and externally irrigated-tip catheter

被引:39
作者
Da Costa, Antoine [1 ]
Romeyer-Bouchard, Cecile
Dauphinot, Virginie
Lipp, Damien
Abdellaoui, Loucif
Messier, Marc
Thevenin, Jerome
Barthelemy, Jean-Claude
Isaaz, Karl
机构
[1] Univ St Etienne, Dept Cardiol, FacMed, F-42055 St Etienne 2, France
[2] Univ St Etienne, Clin Physiol & Exercise Lab, F-42055 St Etienne 2, France
[3] Bakken Res Ctr, NL-6229 GW Maastricht, Netherlands
关键词
atrial flutter; catheter ablation; externally cooled-tip catheter; large-tip catheter; angiography; structure; anatomy;
D O I
10.1093/eurheartj/ehl121
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Radiofrequency ablation (RFA) of cavotricuspid isthmus (CTI)-dependent atrial. flutter can be performed using various types of ablation catheters. Recent evaluations comparing externally cooled-tip RFA (ecRFA) catheters and large-tip (8 mm) catheters found that ecRFA catheter may have a higher efficacy for CTI ablation. The aim of this prospective study was to compare both catheters by stratifying on CTI morphology in order to explain, in part, the discrepancies between previous randomized studies, and to validate predictive factors of difficult CTI ablation on clinical, echocardiographic, and angiographic data. Methods and results Over a period of 24 months, 281 patients were included and stratified on CTI morphology: 'straight', 'concave', and 'pouch-like recess'. In straight CTI (n = 150), the duration of application time with a median of 6 min [interquartile range (IQR) 4-9] vs. a median of 12 min (IQR 16-19; P < 0.0001) and the duration of X-ray exposure with a median of 6 min (IQR 4.4-9.7) vs. a median of 10.4 min (IQR 7-17; P < 0.0001) were significantly lower with an 8 mm-tip when compared with ecRFA catheter. In contrast, in concave CTI (n = 95), a trend towards both shorter application time with a median of 12.5 min (IQR 6-23) vs. a median of 19 min (IQR 7-28; P = 0.08) and X-ray duration exposure with a median of 10.4 min (IQR 6-20) vs. a median of 13 min (IQR 8-24; P = 0.08) with an ecRFA catheter when compared with 8 mm-tip catheter were evidenced. No significant difference was shown between 8 mm-tip and ecRFA catheters in the pouch-like recess group (n = 36). Predictive factors of difficult ablation include right CTI length and morphology. Conclusion This study demonstrates that the 8 mm-tip catheter is more effective for ablation in case of a straight angiographic isthmus morphology and that the ecRFA catheter tends to be more effective in case of concave angiographic isthmus morphology. Thus, angiographic isthmus evaluation may predict both the effectiveness of an RIF catheter, and the risk of an expensive crossover. These data may explain, in part, the discrepancies of previous studies comparing both catheters.
引用
收藏
页码:1833 / 1840
页数:8
相关论文
共 39 条
[31]   Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium - Impact of ablation site, electrode size, and convective cooling [J].
Petersen, HH ;
Chen, X ;
Pietersen, A ;
Svendsen, JH ;
Haunso, S .
CIRCULATION, 1999, 99 (02) :319-325
[32]   Radio frequency catheter ablation of atrial flutter - Further insights into the various types of isthmus block: Application to ablation during sinus rhythm [J].
Poty, H ;
Saoudi, N ;
Nair, M ;
Anselme, F ;
Letac, B .
CIRCULATION, 1996, 94 (12) :3204-3213
[33]   Prospective randomised comparison of irrigated-tip and large-tip catheter ablation of cavotricuspid isthmus-dependent atrial flutter [J].
Scavée, C ;
Jaïs, P ;
Hsu, LF ;
Sanders, P ;
Hocini, M ;
Weerasooriya, R ;
Macle, L ;
Raybaud, F ;
Clementy, J ;
Haïssaguerre, M .
EUROPEAN HEART JOURNAL, 2004, 25 (11) :963-969
[34]   Prospective randomized comparison of closed cooled-tip versus 8-mm-tip catheters for radiofrequency ablation of typical atrial flutter [J].
Schreieck, J ;
Zrenner, B ;
Kumpmann, J ;
Ndrepepa, G ;
Schneider, MAE ;
Deisenhofer, I ;
Schmitt, C .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (10) :980-985
[35]   Tracking dynamic conduction recovery across the cavotricuspid isthmus [J].
Shah, DC ;
Takahashi, A ;
Jaïs, P ;
Hocini, M ;
Peng, JT ;
Clementy, J ;
Haïssaguerre, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (06) :1478-1484
[36]   Simplified electrophysiologically directed catheter ablation of recurrent common atrial flutter [J].
Shah, DC ;
Haissaguerre, M ;
Jais, P ;
Fischer, B ;
Takahashi, A ;
Hocini, M ;
Clementy, J .
CIRCULATION, 1997, 96 (08) :2505-2508
[37]   Effects of intracavitary blood flow and electrode-target distance on radiofrequency power required for transient conduction block in a Langendorff-perfused canine model [J].
Simmers, TA ;
de Bakker, JMT ;
Coronel, R ;
Wittkampf, FHM ;
van Capelle, FJ ;
Janse, MJ ;
Hauer, RNW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (01) :231-235
[38]   Pattern of isthmus conduction recovery using open cooled and solid large-tip catheters for radiofrequency ablation of typical atrial flutter [J].
Ventura, R ;
Klemm, H ;
Lutomsky, B ;
Demir, C ;
Rostock, T ;
Weiss, C ;
Meinertz, T ;
Willems, S .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (10) :1126-1130
[39]  
Yamane T, 2000, CIRCULATION, V102, P2565