Control of column temperature in reversed-phase liquid chromatography

被引:90
作者
Wolcott, RG
Dolan, JW
Snyder, LR
Bakalyar, SR
Arnold, MA
Nichols, JA
机构
[1] LC Resources Inc, Walnut Creek, CA 94596 USA
[2] Linfield Coll, Dept Chem, McMinnville, OR 97128 USA
[3] Rheodyne LP, Rohnert Park, CA 94927 USA
关键词
column temperature; stationary phase; LC;
D O I
10.1016/S0021-9673(99)00894-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
When separations by reversed-phase liquid chromatography (RP-LC) are carried out at temperatures other than ambient, resulting retention times and bandwidths can depend on the equipment used. As a result, an RP-LC separation that is adequate when carried out on one LC system may prove inadequate when the separation is repeated on a second system. In the present study, various temperature-related problems which can result in a failure of method transfer for non-ambient RP-LC methods were examined. Means for correcting for such effects and thereby ensuring method transferability are described. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:211 / 230
页数:20
相关论文
共 29 条
[1]   EFFECT OF RADIAL THERMAL-GRADIENTS IN ELEVATED-TEMPERATURE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ABBOTT, S ;
ACHENER, P ;
SIMPSON, R ;
KLINK, F .
JOURNAL OF CHROMATOGRAPHY, 1981, 218 (1-3) :123-135
[2]   UNSTEADY HEAT-TRANSFER IN CAPILLARY ZONE ELECTROPHORESIS .2. COMPUTER-SIMULATIONS [J].
BELLO, MS ;
RIGHETTI, PG .
JOURNAL OF CHROMATOGRAPHY, 1992, 606 (01) :103-111
[3]   Temperature gradients in preparative high-performance liquid chromatography columns [J].
Brandt, A ;
Mann, G ;
Arlt, W .
JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (01) :109-117
[4]  
CHURCHILL F, 1977, J HEAT TRANSFER, V99, P300
[5]   COMPARISON OF 3-MICROMETER AND 5-MICROMETER COLUMN PACKINGS FOR REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
COOKE, NHC ;
ARCHER, BG ;
OLSEN, K ;
BERICK, A .
ANALYTICAL CHEMISTRY, 1982, 54 (13) :2277-2283
[6]  
DJORDJEVIC DM, 1999, J MICROSEPAR, V11, P403
[7]   Simultaneous variation of temperature and gradient steepness for reversed-phase high-performance liquid chromatography method development - II. The use of further changes in conditions [J].
Dolan, JW ;
Snyder, LR ;
Saunders, DL ;
Van Heukelem, L .
JOURNAL OF CHROMATOGRAPHY A, 1998, 803 (1-2) :33-50
[8]   Reversed-phase liquid chromatographic separation of complex samples by optimizing temperature and gradient time I. Peak capacity limitations [J].
Dolan, JW ;
Snyder, LR ;
Djordjevic, NM ;
Hill, DW ;
Waeghe, TJ .
JOURNAL OF CHROMATOGRAPHY A, 1999, 857 (1-2) :1-20
[9]   Simultaneous variation of temperature and gradient steepness for reversed-phase high-performance liquid chromatography method development - I. Application to 14 different samples using computer simulation [J].
Dolan, JW ;
Snyder, LR ;
Djordjevic, NM ;
Hill, DW ;
Saunders, DL ;
Van Heukelem, L ;
Waeghe, TJ .
JOURNAL OF CHROMATOGRAPHY A, 1998, 803 (1-2) :1-31
[10]  
DOLAN JW, 1999, LC GC, V17, pS17