Determination of multiclass pesticide residues in apple juice by gas chromatography-mass spectrometry with large-volume injection

被引:29
作者
Wang, Jian-Hua [1 ]
Zhang, Yi-Bing [1 ]
Wang, Xiu-Lin [1 ]
机构
[1] Shandong Exit & Entry Inspect & Quarantine Bur, Shandong, Peoples R China
关键词
apple juice; large-volume injection programmed-temperature vaporizer injection; GC-MS; pesticide residue analysis;
D O I
10.1002/jssc.200500250
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study presents two GC-MS SIM methods, in combination with large-volume injection programmed-temperature vaporization (LVI-PTV) injection, for the determination of 141 pesticide residues in apple juice. The sample was extracted with ACN, and coextractives were removed with primary/secondary amine sorbent. ACN extract (20 mu L) Was injected into a PTV injection port in solvent vent mode, and the pesticides were determined by GC-MS using retention time locking software. Deuterium-labeled pesticides (surrogate standards) were used for analytical quality control. In the validation experiments, pesticides recoveries were found to be 70-121% with RSDs of 4.6-21% (n = 6).
引用
收藏
页码:2330 / 2337
页数:8
相关论文
共 16 条
[1]   Determination of herbicide residues in juice by matrix solid-phase dispersion and gas chromatography-mass spectrometry [J].
Albero, B ;
Sánchez-Brunete, C ;
Donoso, A ;
Tadeo, JL .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1043 (02) :127-133
[2]  
Anastassiades M, 2003, J AOAC INT, V86, P412
[3]   Determination of 266 pesticide residues in apple juice by matrix solid-phase dispersion and gas chromatography-mass selective detection [J].
Chu, XG ;
Hu, XZ ;
Yao, HY .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1063 (1-2) :201-210
[4]   Programmed temperature vaporisers-based large volume injection in capillary gas chromatography [J].
Engewald, W ;
Teske, J ;
Efer, J .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :143-161
[5]  
Flllion J, 2000, J AOAC INT, V83, P698
[6]   Trace analysis of pesticide residues in water by high-speed narrow-bore capillary gas chromatography-mass spectrometry with programmable temperature vaporizer [J].
Hada, M ;
Takino, M ;
Yamagami, T ;
Daishima, S ;
Yamaguchi, K .
JOURNAL OF CHROMATOGRAPHY A, 2000, 874 (01) :81-90
[7]  
Hu XZ, 2004, J AOAC INT, V87, P972
[8]   Evaluation of common organic solvents for gas chromatographic analysis and stability of multiclass pesticide residues [J].
Mastovská, K ;
Lehotay, SJ .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1040 (02) :259-272
[9]  
PRSET H, 1999, 59683797E AGL TECHN
[10]  
Schenck FJ, 2002, J AOAC INT, V85, P1177