In vivo uptake and elimination of isoflurane by different membrane oxygenators during cardiopulmonary bypass

被引:59
作者
Wiesenack, C [1 ]
Wiesner, G
Keyl, C
Gruber, M
Philipp, A
Ritzka, M
Prasser, C
Taeger, K
机构
[1] Univ Hosp, Dept Anesthesiol, D-93042 Regensburg, Germany
[2] Univ Hosp, Dept Cardiothorac Surg, D-93042 Regensburg, Germany
关键词
D O I
10.1097/00000542-200207000-00019
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Volatile anesthetics are frequently used during cardiopulmonary bypass (CPB) to maintain anesthesia. Uptake and elimination of the volatile agent are dependent on the composition of the oxygenator. This study was designed to evaluate whether the in vivo uptake and elimination of isoflurane differs between microporous membrane oxygenators containing a conventional polypropylene (PPL) membrane and oxygenators with a new poly-(4-methyl-1-pentene) (PMP) membrane measuring isoflurane concentrations in blood. Methods: Twenty-four patients undergoing elective coronary bypass surgery with the aid of CPB were randomly allocated to one of four groups, using either one of two different PPL-membrane oxygenators for CPB or one of two different PMP-membrane oxygenators. During hypothermic CPB, 1% isoflurane in an oxygen-air mixture was added to the oxygenator gas inflow line (gas flow, 3 l/min) for 15 min. Isoflurane concentration was measured in blood and in exhaust gas at the outflow port of the oxygenator. Between-group comparisons were performed for the area under the curve (AUC) during uptake and elimination of the isoflurane blood concentrations, the maximum isoflurane blood concentration (C-max), and the exhausted isoflurane concentration (F-E). Results: The uptake of isoflurane, expressed as AUC of isoflurane blood concentration and a function of F-E, was significantly reduced in PMP oxygenators compared to PPL oxygenators (P < 0.01). C-max was between 8.5 and 13 times lower in the PMP-membrane oxygenator groups compared to the conventional PPL-membrane oxygenator groups (P < 0.01). Conclusions: The uptake of isoflurane into blood via PMP oxygenators during CPB is severely limited. This should be taken into consideration in cases using such devices.
引用
收藏
页码:133 / 138
页数:6
相关论文
共 25 条
[1]  
Alston R P, 1992, J Cardiothorac Vasc Anesth, V6, P700, DOI 10.1016/1053-0770(92)90055-C
[2]  
Belhomme D, 1999, CIRCULATION, V100, P340
[3]   GAS-CHROMATOGRAPHIC DETERMINATION OF VOLATILE ANESTHETIC AGENTS IN BLOOD .2. CLINICAL-STUDIES [J].
FLYNN, J ;
MASUD, S ;
OKEEFFE, JD ;
WREN, WS ;
SHANAHAN, IM .
ANALYST, 1989, 114 (10) :1211-1213
[4]   Does isoflurane optimize myocardial protection during cardiopulmonary bypass? [J].
Haroun-Bizri, S ;
Khoury, SS ;
Chehab, IR ;
Kassas, CM ;
Baraka, A .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2001, 15 (04) :418-421
[5]   WASHIN AND WASHOUT OF ISOFLURANE DURING CARDIOPULMONARY BYPASS [J].
HENDERSON, JM ;
NATHAN, HJ ;
LALANDE, M ;
WINKLER, MH ;
DUBE, LM .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1988, 35 (06) :587-590
[6]   In vitro uptake and elimination of isoflurane by different membrane oxygenators [J].
Hickey, S ;
Gaylor, JDS ;
Kenny, GNC .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1996, 10 (03) :352-355
[7]  
JOSTRA AG, 2001, INSTRUCTION USE QUAD
[8]   Mechanism of myocardial protection by isoflurane - Role of adenosine triphosphate-regulated potassium (K-ATP) channels [J].
Kersten, JR ;
Schmeling, TJ ;
Hettrick, DA ;
Pagel, PS ;
Gross, GJ ;
Warltier, DC .
ANESTHESIOLOGY, 1996, 85 (04) :794-807
[9]   A comparison of anaesthetic tensions in arterial blood and oxygenator exhaust gas during cardiopulmonary bypass [J].
Lockwood, GG ;
Sapsed-Byrne, SM ;
Adams, S .
ANAESTHESIA, 1999, 54 (05) :434-436
[10]   ARTERIAL ISOFLURANE CONCENTRATION AND EEG BURST SUPPRESSION DURING CARDIOPULMONARY BYPASS [J].
LOOMIS, CW ;
BRUNET, D ;
MILNE, B ;
CERVENKO, FW ;
JOHNSON, GD .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1986, 40 (03) :304-313