Preparation of magnetic molecularly imprinted polymer for the separation of tetracycline antibiotics from egg and tissue samples

被引:240
作者
Chen, Ligang [1 ]
Liu, Jun [1 ]
Zeng, Qinglei [1 ]
Wang, Hui [1 ]
Yu, Aimin [1 ]
Zhang, Hanqi [1 ]
Ding, Lan [1 ]
机构
[1] Jilin Univ, Coll Chem, Changchun 130012, Peoples R China
关键词
Magnetic molecularly imprinted polymers; Tetracycline antibiotics; Egg; Tissue; Liquid chromatography-tandem mass spectrometry; SOLID-PHASE EXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; MICROWAVE-ASSISTED EXTRACTION; SELECTIVE EXTRACTION; MASS-SPECTROMETRY; RESIDUE ANALYSIS; FOOD; DISPERSION; MICROEXTRACTION; METABOLITES;
D O I
10.1016/j.chroma.2009.02.044
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Magnetic molecularly imprinted polymers were prepared using hydrophobic Fe3O0 magnetite as the magnetically susceptible component, oxytetracycline as template molecule, methacrylic acid as functional monomer, and styrene and divinylbenzene as polymeric matrix components. The polymers were applied to the separation of tetracycline antibiotics from egg and tissue samples. The extraction and clean-up procedures were carried out in a single step by blending and stirring the sample, extraction solvent and polymers. The analytes can be transferred from the sample matrix to the polymers directly or through the extraction solvent as medium. When the extraction was complete, the polymers adsorbing the analytes were easily separated from the sample matrix by an adscititious magnet. The analytes eluted from the polymers were determined by liquid chromatography-tandem mass spectrometry. The recoveries ranging from 72.8% to 96.5% were obtained with relative standard deviations in the range of 2.9-12.3%. The limit of detection was less than 0.2 ng g(-1). The feasibility of this method was validated by analysis of incurred egg and tissue samples, and the results were compared with those obtained by the classical method in which solvent extraction, centrifugation, and subsequent clean-up and concentration by solid-phase extraction were applied. The proposed method reduced the complicacy of classical method and improved the reliability of method. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3710 / 3719
页数:10
相关论文
共 54 条
  • [1] Magnetic molecularly imprinted polymer beads for drug radioligand binding assay
    Ansell, RJ
    Mosbach, K
    [J]. ANALYST, 1998, 123 (07) : 1611 - 1616
  • [2] Oriented immobilization of galactose oxidase to bead and magnetic bead cellulose and poly(HEMA-co-EDMA) and magnetic poly(HEMA-co-EDMA) microspheres
    Bílková, Z
    Slováková, M
    Lycka, A
    Horák, D
    Lenfeld, J
    Turková, J
    Churácek, J
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 770 (1-2): : 25 - 34
  • [3] A rapid confirmatory method for analyzing tetracycline antibiotics in bovine, swine, and poultry muscle tissues:: Matrix solid-phase dispersion with heated water as extractant followed by liquid chromatography-tandem mass spectrometry
    Bogialli, S
    Curini, R
    Di Corcia, A
    Laganà, A
    Rizzuti, G
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (05) : 1564 - 1570
  • [4] A liquid chromatography-mass spectrometry assay for analyzing sulfonamide antibacterials in cattle and fish muscle tissues
    Bogialli, S
    Curini, R
    Di Corcia, A
    Nazzari, M
    Samperi, R
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (08) : 1798 - 1804
  • [5] Recent applications of sample preparation techniques in food analysis
    Buldini, PL
    Ricci, L
    Sharma, JL
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (01) : 47 - 70
  • [6] Pressurized liquid extraction in the analysis of food and biological samples
    Carabias-Martínez, R
    Rodríguez-Gonzalo, E
    Revilla-Ruiz, P
    Hernández-Méndez, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1089 (1-2) : 1 - 17
  • [7] Synthesis and application of an oxytetracycline imprinted polymer for the solid-phase extraction of tetracycline antibiotics
    Caro, E
    Marcé, RM
    Cormack, PAG
    Sherrington, DC
    Borrull, F
    [J]. ANALYTICA CHIMICA ACTA, 2005, 552 (1-2) : 81 - 86
  • [8] Multi-residue screening of chlorinated and brominated compounds from aquaculture samples using matrix solid-phase dispersion-gas chromatography-mass spectrometry
    Carro, AM
    Lorenzo, RA
    Fernández, F
    Rodil, R
    Cela, R
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1071 (1-2) : 93 - 98
  • [9] Determination of triazine herbicides in sheep liver by microwave-assisted extraction and high performance liquid chromatography
    Cheng, Jianhua
    Liu, Miao
    Zhang, Xinyou
    Ding, Lan
    Yu, Yong
    Wang, Xiupin
    Jin, Haiyan
    Zhang, Hanqi
    [J]. ANALYTICA CHIMICA ACTA, 2007, 590 (01) : 34 - 39
  • [10] Quantitative multi-residue analysis of tetracyclines and their 4-epimers in pig tissues by high-performance liquid chromatography combined with positive-ion electrospray ionization mass spectrometry
    Cherlet, M
    Schelkens, M
    Croubels, S
    De Backer, P
    [J]. ANALYTICA CHIMICA ACTA, 2003, 492 (1-2) : 199 - 213