Robust, high-speed, all-optical atomic magnetometer

被引:54
作者
Higbie, J. M. [1 ]
Corsini, E.
Budker, D.
机构
[1] Univ Calif Berkeley, Dept Phys, Berkeley, CA 94720 USA
[2] Lawrence Berkeley Lab, Div Nucl Sci, Berkeley, CA 94720 USA
关键词
D O I
10.1063/1.2370597
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A self-oscillating magnetometer based on the nonlinear magneto-optical rotation effect with separate modulated pump and unmodulated probe beams is demonstrated. This device possesses a bandwidth exceeding 1 kHz. Pump and probe are delivered by optical fiber, facilitating miniaturization and modularization. The magnetometer has been operated both with vertical-cavity surface-emitting lasers, which are well suited to portable applications, and with conventional edge-emitting diode lasers. A sensitivity of around 3 nG is achieved for a measurement time of 1 s.
引用
收藏
页数:7
相关论文
共 29 条
[1]   Nonlinear magneto-optical rotation with frequency-modulated light in the geophysical field range [J].
Acosta, V. ;
Ledbetter, M. P. ;
Rochester, S. M. ;
Budker, D. ;
Kimball, D. F. Jackson ;
Hovde, D. C. ;
Gawlik, W. ;
Pustelny, S. ;
Zachorowski, J. ;
Yashchuk, V. V. .
PHYSICAL REVIEW A, 2006, 73 (05)
[2]   Space-based magnetometers [J].
Acuña, MH .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (11) :3717-3736
[3]   An all-optical, high-sensitivity magnetic gradiometer [J].
Affolderbach, C ;
Stähler, M ;
Knappe, S ;
Wynands, R .
APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 75 (6-7) :605-612
[4]   High precision measurement of the static dipole polarizability of cesium [J].
Amini, JM ;
Gould, H .
PHYSICAL REVIEW LETTERS, 2003, 91 (15)
[5]   Can a quantum nondemolition measurement improve the sensitivity of an atomic magnetometer? [J].
Auzinsh, M ;
Budker, D ;
Kimball, DF ;
Rochester, SM ;
Stalnaker, JE ;
Sushkov, AO ;
Yashchuk, VV .
PHYSICAL REVIEW LETTERS, 2004, 93 (17) :173002-1
[6]   NEW LIMITS ON LOCAL LORENTZ INVARIANCE FROM HG AND CS MAGNETOMETERS [J].
BERGLUND, CJ ;
HUNTER, LR ;
KRAUSE, D ;
PRIGGE, EO ;
RONFELDT, MS ;
LAMOREAUX, SK .
PHYSICAL REVIEW LETTERS, 1995, 75 (10) :1879-1882
[7]   A laser-pumped magnetometer for the mapping of human cardiomagnetic fields [J].
Bison, G ;
Wynands, R ;
Weis, A .
APPLIED PHYSICS B-LASERS AND OPTICS, 2003, 76 (03) :325-328
[8]   PRINCIPLES OF OPERATION OF THE RUBIDIUM VAPOR MAGNETOMETER [J].
BLOOM, AL .
APPLIED OPTICS, 1962, 1 (01) :61-68
[9]   Nonlinear magneto-optical rotation via alignment-to-orientation conversion [J].
Budker, D ;
Kimball, DF ;
Rochester, SM ;
Yashchuk, VV .
PHYSICAL REVIEW LETTERS, 2000, 85 (10) :2088-2091
[10]   Nonlinear magneto-optical rotation with frequency-modulated light [J].
Budker, D ;
Kimball, DF ;
Yashchuk, VV ;
Zolotorev, M .
PHYSICAL REVIEW A, 2002, 65 (05) :4