Implementation of suitable flow injection/sequential injection-sample separation/preconcentration schemes for determination of trace metal concentrations using detection by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

被引:48
作者
Hansen, EH [1 ]
Wang, JH [1 ]
机构
[1] Tech Univ Denmark, Dept Chem, DK-2800 Lyngby, Denmark
关键词
sample pretreatment; preconcentration and separation; ion-exchange; liquid-liquid extraction; sequential injection; lab-on-valve;
D O I
10.1016/S0003-2670(02)00060-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Various preconditioning procedures encomprising appropriate separation/preconcentration schemes in order to obtain optimal sensitivity and selectivity characteristics when using electrothermal atomic absorption spectrometry (ETAAS) and inductively coupled plasma mass spectrometry (ICPMS) are presented and discussed. Demonstrating that such pretreatments advantageously are to be performed in flow injection (FI) or sequential injection (SI) manifolds, where all appropriate unit operations can be effected under enclosed and strictly controlled conditions, procedures based on ion-exchange, precipitation/coprecipitation, adsorption, liquid-liquid extraction, extraction/back-extraction and hydride generation are reviewed. Emphasising the use of SI-systems, special attention is paid to the use of the newly introduced approach termed the lab-on-valve (LOV), where all necessary manipulations required prior to detection are effected in a microconduit placed on top of an SI selection valve. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:3 / 12
页数:10
相关论文
共 35 条
[1]   Flow injection on-line electrothermal atomic absorption spectrometry [J].
Alonso, EV ;
de Torres, AG ;
Pavón, JMC .
TALANTA, 2001, 55 (02) :219-232
[2]   DESIGN OF A CONTINUOUS-FLOW 2-STEP EXTRACTION SAMPLE WORK-UP SYSTEM FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BACKSTROM, K ;
DANIELSSON, LG .
ANALYTICA CHIMICA ACTA, 1990, 232 (02) :301-315
[3]   Flow injection manifold for matrix removal in inductively coupled plasma mass spectrometry by solid phase extraction: determination of Al, Be, Li and Mg in a uranium matrix [J].
Becotte-Haigh, P ;
Tyson, JF ;
Denoyer, E .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (12) :1327-1331
[4]   Determination of sub-parts-per-trillion levels of rare earth elements in natural waters by inductively coupled plasma time-of-flight mass spectrometry after flow injection on-line sorption preconcentration in a knotted reactor [J].
Benkhedda, K ;
Infante, HG ;
Ivanova, E ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (09) :995-1001
[5]   Ultratrace determination of cobalt in natural waters by electrothermal atomic absorption spectrometry using flow-injection on-line sorption preconcentration in a knotted reactor precoated with 1-phenyl-3-methyl-benzoylpyrazol-5-one [J].
Benkhedda, K ;
Infante, HG ;
Ivanova, E ;
Adams, F .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (04) :429-434
[6]   Trace metal analysis of natural waters and biological samples by axial inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS) with flow injection on-line adsorption preconcentration using a knotted reactor [J].
Benkhedda, K ;
Infante, HG ;
Ivanova, E ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (10) :1349-1356
[7]   Selective medium reactions for the 'arsenic(III)', 'arsenic(V)', dimethylarsonic acid and monomethylarsonic acid determination in waters by hydride generation on-line electrothermal atomic absorption spectrometry with in situ preconcentration on Zr-coated graphite tubes [J].
Bermejo-Barrera, P ;
Moreda-Piñeiro, J ;
Moreda-Piñeiro, A ;
Bermejo-Barrera, A .
ANALYTICA CHIMICA ACTA, 1998, 374 (2-3) :231-240
[8]  
Fang Z., 1995, FLOW INJECTION ATOMI
[9]   AN EFFICIENT FLOW-INJECTION SYSTEM WITH ONLINE ION-EXCHANGE PRECONCENTRATION FOR THE DETERMINATION OF TRACE AMOUNTS OF HEAVY-METALS BY ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, ZL ;
RUZICKA, J ;
HANSEN, EH .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :23-39
[10]   FLOW-INJECTION ONLINE COPRECIPITATION PRECONCENTRATION FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, ZL ;
DONG, LP .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :439-445