Implementation of suitable flow injection/sequential injection-sample separation/preconcentration schemes for determination of trace metal concentrations using detection by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

被引:48
作者
Hansen, EH [1 ]
Wang, JH [1 ]
机构
[1] Tech Univ Denmark, Dept Chem, DK-2800 Lyngby, Denmark
关键词
sample pretreatment; preconcentration and separation; ion-exchange; liquid-liquid extraction; sequential injection; lab-on-valve;
D O I
10.1016/S0003-2670(02)00060-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Various preconditioning procedures encomprising appropriate separation/preconcentration schemes in order to obtain optimal sensitivity and selectivity characteristics when using electrothermal atomic absorption spectrometry (ETAAS) and inductively coupled plasma mass spectrometry (ICPMS) are presented and discussed. Demonstrating that such pretreatments advantageously are to be performed in flow injection (FI) or sequential injection (SI) manifolds, where all appropriate unit operations can be effected under enclosed and strictly controlled conditions, procedures based on ion-exchange, precipitation/coprecipitation, adsorption, liquid-liquid extraction, extraction/back-extraction and hydride generation are reviewed. Emphasising the use of SI-systems, special attention is paid to the use of the newly introduced approach termed the lab-on-valve (LOV), where all necessary manipulations required prior to detection are effected in a microconduit placed on top of an SI selection valve. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:3 / 12
页数:10
相关论文
共 35 条
[31]   Development of an automated sequential injection on-line solvent extraction-back extraction procedure as demonstrated for the determination of cadmium with detection by electrothermal atomic absorption spectrometry [J].
Wang, JH ;
Hansen, EH .
ANALYTICA CHIMICA ACTA, 2002, 456 (02) :283-292
[32]  
Wang JH, 2001, ATOM SPECTROSC, V22, P312
[33]   Coupling sequential injection on-line preconcentration by means of a renewable microcolumn with ion-exchange beads with detection by electrothermal atomic absorption spectrometry - Comparing the performance of eluting the loaded beads with transporting them directly into the graphite tube, as demonstrated for the determination of nickel in environmental and biological samples [J].
Wang, JH ;
Hansen, EH .
ANALYTICA CHIMICA ACTA, 2001, 435 (02) :331-342
[34]   Interfacing sequential injection on-line preconcentration using a renewable micro-column incorporated in a 'lab-on-valve' system with direct injection nebulization inductively coupled plasma mass spectrometry [J].
Wang, JH ;
Hansen, EH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (12) :1349-1355
[35]   A sequential injection on-line column preconcentration system for determination of cadmium by electrothermal atomic absorption spectrometry [J].
Xu, ZR ;
Pan, HY ;
Xu, SK ;
Fang, ZL .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (03) :213-219