Adaptive bilateral breast MRI using projection reconstruction time-resolved imaging of contrast kinetics

被引:14
作者
Ramsay, E.
Causer, P.
Hill, K.
Plewes, D.
机构
[1] Sunnybrook & Womens Coll, Hlth Sci Ctr, Div Imaging Res, Toronto, ON M4N 3M5, Canada
[2] Sunnybrook & Womens Coll, Hlth Sci Ctr, Dept Med Imaging, Toronto, ON M4N 3M5, Canada
[3] Sunnybrook & Womens Coll, Hlth Sci Ctr, Toronto Sunnybrook Reg Canc Ctr, Toronto, ON M4N 3M5, Canada
关键词
bilateral breast MRI; projection reconstruction; PR-TRICKS; dynamic imaging; adaptive reconstruction; TEMPORAL RESOLUTION; ANGIOGRAPHY; SURVEILLANCE; MAMMOGRAPHY; ULTRASOUND; CANCER;
D O I
10.1002/jmri.20685
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To introduce a bilateral implementation of an adaptive imaging technique in which both dynamic and high resolution breast MR images are acquired simultaneously. Materials and Methods: Adaptive three-dimensional bilateral breast imaging in the sagittal plane was achieved by combining two elements: a projection reconstruction timeresolved imaging of contrast kinetics (PR-TRICKS) k-space trajectory and a slab interleaved sequence that imaged alternate breasts every TR. A pilot study was performed to evaluate image quality and contrast uptake behavior, using eight patients with previously identified benign lesions. Results: Adaptive reconstruction demonstrated breast lesions in all eight women with similar image quality and signal-to-noise ratio (SNR) to Cartesian images with comparable imaging parameters. Contrast enhancement curves covering the entire postinjection time period were obtained from the dynamic images and in one case compared to previous enhancement profiles from a conventional Cartesian trajectory. Conclusion: Bilateral dynamic and high spatial resolution images with high SNR can be achieved in a clinically feasible manner. providing both kinetic and morphologic analysis with a single data set. This may obviate the need for multiple MRI examinations for a thorough breast MRI workup.
引用
收藏
页码:617 / 624
页数:8
相关论文
共 30 条
  • [1] ANGELOS L, 2003, P 11 ANN M ISMRM TOR
  • [2] Breast disease: Dynamic spiral MR imaging
    Daniel, BL
    Yen, YF
    Glover, GH
    Ikeda, DM
    Birdwell, RL
    Sawyer-Glover, AM
    Black, JW
    Plevritis, SK
    Jeffrey, SS
    Herfkens, RJ
    [J]. RADIOLOGY, 1998, 209 (02) : 499 - 509
  • [3] FAIN SB, 2004, P 12 ANN M ISMRM KYO
  • [4] Bilateral imaging using separate interleaved 3D volumes and dynamically switched multiple receive coil arrays
    Greenman, RL
    Lenkinski, RE
    Schnall, MD
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (01) : 108 - 115
  • [5] HOPPEL BE, 2004, P 12 ANN M ISMRM KYO
  • [6] JACKSON JI, 1991, IEEE T MED IMAGING, V10, P474
  • [7] Dynamic high-spatial-resolution MR imaging of suspicious breast lesions: Diagnostic criteria and interobserver variability
    Kinkel, K
    Helbich, TH
    Esserman, LJ
    Barclay, J
    Schwerin, EH
    Sickles, EA
    Hylton, NM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (01) : 35 - 43
  • [8] Comparison of MR Imaging breast coils
    Konyer, NB
    Ramsay, EA
    Bronskill, M
    Plewes, DB
    [J]. RADIOLOGY, 2002, 222 (03) : 830 - 834
  • [9] Time-resolved contrast-enhanced 3D MR angiography
    Korosec, FR
    Frayne, R
    Grist, TM
    Mistretta, CA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) : 345 - 351
  • [10] Kuhl CK, 2000, J MAGN RESON IMAGING, V12, P965, DOI 10.1002/1522-2586(200012)12:6<965::AID-JMRI23>3.0.CO