Sensitive, simultaneous determination of P, S, Cl, Br and I containing pesticides in environmental samples by GC hyphenated with collision-cell ICP-MS

被引:69
作者
Pröfrock, D
Leonhard, P
Wilbur, S
Prange, A
机构
[1] GKSS Forschungszentrum Geesthacht GmbH, Inst Coastal Res Operat Syst Marine Bioanalyt Che, D-21502 Geesthacht, Germany
[2] Agilent Technol, Bellevue, WA 98007 USA
关键词
D O I
10.1039/b310530j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and highly selective methodology for the determination of a wide range of pesticides, based on the simultaneous element-specific determination of phosphorus, sulfur, chloride, bromine and iodine by gas chromatography hyphenated with octopole reaction cell-inductively coupled plasma mass spectrometry (GC-CC-ICP-MS) is described. The chromatographic system was optimised for separation efficiency and short run times and was coupled via a commercially available interface with an octopole reaction cell ICP-MS system which is equipped with an on-axis collision cell. Instrumental settings were optimised with respect to high sensitivity for the target nuclides P-31, S-32, Cl-35, Br-79 and I-12 and minimized background levels especially for the ions most affected by interferences, such as P-31(+), S-32(+). Helium and nitrogen were tested as additional plasma gases for possible sensitivity enhancement of the element-specific detection resulting from improved ionisation processes inside the plasma. Due to the multi-element capability of the instrumental setup and the good accuracy of the retention times that were achieved, identification of the detected pesticides can be carried out using their retention times, the element compositions and element ratios present in each chromatographic peak. For the different pesticides detection limits down to the ppt level or the low ppb level were obtained. The average RSDs of the retention times and the peak areas were better than 0.8% and 8%, respectively. The analytical methodology developed has been applied to the screening of different fruit extracts for pesticides. Peaks were identified by comparison of the retention times obtained and by their elemental composition. Quantitative results have been obtained both by external calibration and by using a compound independent calibration.
引用
收藏
页码:623 / 631
页数:9
相关论文
共 40 条
[1]   Enzymatic digestion for the determination of trace elements in blood serum by inductively coupled plasma mass spectrometry [J].
AbouShakra, FR ;
Rayman, MP ;
Ward, NI ;
Hotton, V ;
Bastian, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) :429-433
[2]   The potential of inductively coupled plasma mass spectrometry detection for high-performance liquid chromatography combined with accurate mass measurement of organic pharmaceutical compounds [J].
Axelsson, BO ;
Jörnten-Karlsson, M ;
Michelsen, P ;
Abou-Shakra, F .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (06) :375-385
[3]   Fragmentation and reactions of organophosphate ions produced by electrospray ionization [J].
Bell, AJ ;
Despeyroux, D ;
Murrell, J ;
Watts, P .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 165 :533-550
[4]   ATMOSPHERIC DEPOSITION OF TRIAZINE HERBICIDES IN NORTHERN GERMANY AND THE GERMAN BIGHT (NORTH-SEA) [J].
BESTER, K ;
HUHNERFUSS, H ;
NEUDORF, B ;
THIEMANN, W .
CHEMOSPHERE, 1995, 30 (09) :1639-1653
[5]   Gas chromatography with inductively coupled plasma mass spectrometric detection in speciation analysis [J].
Bouyssiere, B ;
Szpunar, J ;
Lobinski, R .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (05) :805-828
[6]  
Cook J, 1999, J AOAC INT, V82, P313
[7]  
Cook J, 1999, J AOAC INT, V82, P1419
[8]   ALTERNATIVES TO ALL-ARGON PLASMAS IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS) - AN OVERVIEW [J].
DURRANT, SF .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (10-11) :389-392
[9]   The determination of iodine species in environmental and biological samples (Technical report) [J].
Edmonds, JS ;
Morita, M .
PURE AND APPLIED CHEMISTRY, 1998, 70 (08) :1567-1584
[10]  
*EUR PARL RAT SCHA, 2000, RICHTL 2000 60 EG EU