Simultaneous amplitude-contrast and quantitative phase-contrast microscopy by numerical reconstruction of Fresnel off-axis holograms

被引:954
作者
Cuche, E [1 ]
Marquet, P
Depeursinge, C
机构
[1] Swiss Fed Inst Technol, Inst Appl Opt, CH-1015 Lausanne, Switzerland
[2] Univ Lausanne, Dept Neurol, Lab Neurol Res, Inst Physiol, CH-1005 Lausanne, Switzerland
关键词
D O I
10.1364/AO.38.006994
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a digital method for holographic microscopy involving a CCD camera as a recording device. Off-axis holograms recorded with a magnified image of microscopic objects are numerically reconstructed in amplitude and phase by calculation of scaler diffraction in the Fresnel approximation. For phase-contrast imaging the reconstruction method involves the computation of a digital replica of the reference wave. A digital method for the correction of the phase aberrations is presented. We present a detailed description of the reconstruction procedure and show that the transverse resolution is equal to the diffraction limit of the imaging system. (C) 1999 Optical Society of America OCIS codes: 090.0090, 110.0180, 040.1520, 350.5030, 090.1000.
引用
收藏
页码:6994 / 7001
页数:8
相关论文
共 20 条
  • [1] Biomedical three-dimensional holographic microimaging at visible, ultraviolet and X-ray wavelengths
    Boyer, K
    Solem, JC
    Longworth, JW
    Borisov, AB
    Rhodes, CK
    [J]. NATURE MEDICINE, 1996, 2 (08) : 939 - 941
  • [2] PERFORMANCES OF ENDOSCOPIC HOLOGRAPHY WITH A MULTICORE OPTICAL-FIBER
    COQUOZ, O
    CONDE, R
    TALEBLOU, F
    DEPEURSINGE, C
    [J]. APPLIED OPTICS, 1995, 34 (31): : 7186 - 7193
  • [3] Optical tomography by means of a numerical low-coherence holographic technique
    Cuche, E
    Poscio, P
    Depeursinge, C
    [J]. JOURNAL OF OPTICS-NOUVELLE REVUE D OPTIQUE, 1997, 28 (06): : 260 - 264
  • [4] Digital holography for quantitative phase-contrast imaging
    Cuche, E
    Bevilacqua, F
    Depeursinge, C
    [J]. OPTICS LETTERS, 1999, 24 (05) : 291 - 293
  • [5] Optical tomography at the microscopic scale by means of a numerical low coherence holographic technique
    Cuche, E
    Poscio, P
    Depeursinge, C
    [J]. OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING II, PROCEEDINGS OF, 1996, 2927 : 61 - 66
  • [6] DIGITAL IMAGE FORMATION FROM ELECTRONICALLY DETECTED HOLOGRAMS
    GOODMAN, JW
    LAWRENCE, RW
    [J]. APPLIED PHYSICS LETTERS, 1967, 11 (03) : 77 - +
  • [7] GOODMAN JW, 1968, INTRO FOURIER OPTICS, pCH5
  • [8] Greivenkamp J. E., 1992, OPTICAL SHOP TESTING, P501
  • [9] FOURIER-TRANSFORM HOLOGRAPHIC MICROSCOPE
    HADDAD, WS
    CULLEN, D
    SOLEM, JC
    LONGWORTH, JW
    MCPHERSON, A
    BOYER, K
    RHODES, CK
    [J]. APPLIED OPTICS, 1992, 31 (24) : 4973 - 4978
  • [10] Kronrod M. A., 1972, Soviet Physics - Technical Physics, V17, P333