Enhanced color flow images in small hepatocellular carcinoma

被引:32
作者
Maruyama, H
Matsutani, S
Sato, G
Nakano, Y
Mitsuhashi, O
Yoshikawa, M
Ebara, M
Saisho, H
Ohto, M
机构
[1] Chiba Univ, Sch Med, Dept Med 1, Chuou Ku, Chiba 2600856, Japan
[2] Natl Inst Radiol Sci, Inage Ku, Chiba 2600024, Japan
来源
ABDOMINAL IMAGING | 2000年 / 25卷 / 02期
关键词
small hepatocellular carcinoma; tumor vascularity; microbubble; color Doppler;
D O I
10.1007/s002619910037
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Features of enhanced color flow images in small hepatocellular carcinoma (HCC) are not fully elucidated. The purpose of this study was to clarify the characteristic vascular images in small HCC observed by enhanced color Doppler, Methods: Enhanced color Doppler using the contrast agent Levovist was performed on 13 patients with HCC smaller than 30 mm, Enhanced color flow appearance was compared with angiographic findings. Time-intensity changes after injection of the contrast agent were analyed in HCC nodules. Results: Significant improvement in the detection of color flow signals was obtained in small HCC using Levovist, from 33% in precontrast to 92% in postcontrast (p < 0.005). Three patterns of enhanced color how images, which were related to the angiographic findings, were observed. The time-intensity curve was classified into two types by "time to peak" and "time on plateau" and was associated with the patterns of enhanced images. Conclusion: Enhanced color flow imaging promises to be a useful method for evaluating tumor vascularity noninvasively and to contribute to the elucidation of the hemodynamics in small HCC.
引用
收藏
页码:164 / 171
页数:8
相关论文
共 28 条
[1]  
Angeli E, 1994, Radiol Med, V87, P24
[2]   PERFLUOROOCTYLBROMIDE AS A CONTRAST AGENT FOR CT AND SONOGRAPHY - PRELIMINARY CLINICAL-RESULTS [J].
BEHAN, M ;
OCONNELL, D ;
MATTREY, RF ;
CARNEY, DN .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (02) :399-405
[3]   Color flow mapping [J].
Ferrara, K ;
DeAngelis, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (03) :321-345
[4]   COLOR DOPPLER FLOW IMAGING [J].
FOLEY, WD ;
ERICKSON, SJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (01) :3-13
[5]   SH-U-508, A TRANSPULMONARY ECHOCONTRAST AGENT - INITIAL EXPERIENCE [J].
FRITZSCH, T ;
HILMANN, J ;
KAMPFE, M ;
MULLER, N ;
SCHOBEL, C ;
SIEGERT, J .
INVESTIGATIVE RADIOLOGY, 1990, 25 :S160-S161
[6]   COLOR DOPPLER SONOGRAPHY OF HEPATIC-TUMORS WITH A GALACTOSE-BASED CONTRAST AGENT - CORRELATION WITH ANGIOGRAPHIC FINDINGS [J].
FUJIMOTO, M ;
MORIYASU, F ;
NISHIKAWA, K ;
NADA, T ;
OKUMA, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) :1099-1104
[7]   HEPATIC-TUMORS - SIGNAL ENHANCEMENT AT DOPPLER US AFTER INTRAVENOUS-INJECTION OF A CONTRAST AGENT [J].
GOLDBERG, BB ;
HILPERT, PL ;
BURNS, PN ;
LIU, JB ;
NEWMAN, LM ;
MERTON, DA ;
WITLIN, LA .
RADIOLOGY, 1990, 177 (03) :713-717
[8]   GALACTOSE-BASED INTRAVENOUS SONOGRAPHIC CONTRAST AGENT - EXPERIMENTAL STUDIES [J].
GOLDBERG, BB ;
LIU, JB ;
BURNS, PN ;
MERTON, DA .
JOURNAL OF ULTRASOUND IN MEDICINE, 1993, 12 (08) :463-470
[9]  
Gramiak R, 1968, Invest Radiol, V3, P356
[10]   CLINICAL DOPPLER IMAGING [J].
GRANT, EG ;
TESSLER, FN ;
PERRELLA, RR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (04) :707-717