Quantization of setup uncertainties in 3-D dose calculations

被引:44
作者
Lujan, AE [1 ]
Ten Haken, RK
Larsen, EW
Balter, JM
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
关键词
patient setup uncertainty; treatment verification; treatment planning; dose calculations;
D O I
10.1118/1.598756
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Random setup errors can lead to erroneous prediction of the dose distribution calculated for a patient using a static computed tomography (CT) model. Multiple recomputations of the dose distribution covering the range of expected patient positions provides a way to estimate a course of treatment. However, due to the statistical nature of the setup uncertainties, many courses of treatment must be simulated to calculate a distribution of average dose values delivered to a patient. Thus, direct simulation methods can be time consuming and may be impractical for routine clinical treatment planning applications. Methods have been proposed to efficiently calculate the distribution of average dose values via a convolution of the dose distribution (calculated on a static CT model) with a probability distribution function (generally Gaussian) that describes the nature of the uncertainty. In this paper, we extend the convolution-based calculation to calculate the standard deviation of potential outcomes sigma(D)(x,y,z) about the distribution of average dose values, and we characterize the statistical significance of this quantity using the central limit theorem. For an example treatment plan based on a treatment protocol in use at our institution, we found that there is a 68% probability that the actual dose delivered to any point (x,y,z) will be within 3% of the average dose value at that point. The standard deviation also yields confidence limits on the dose distribution, and these may be used to evaluate treatment plan stability. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)02411-6].
引用
收藏
页码:2397 / 2402
页数:6
相关论文
共 19 条
[1]   Target margins for random geometrical treatment uncertainties in conformal radiotherapy [J].
Bel, A ;
vanHerk, M ;
Lebesque, JV .
MEDICAL PHYSICS, 1996, 23 (09) :1537-1545
[2]   FITTING OF NORMAL TISSUE TOLERANCE DATA TO AN ANALYTIC-FUNCTION [J].
BURMAN, C ;
KUTCHER, GJ ;
EMAMI, B ;
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :123-135
[3]  
CARTER LL, TID26607 US DEP COMM
[4]  
Chui C. S., 1992, MED PHYS, V19, P814
[5]  
Hunt M. A., 1993, MED PHYS, V20, P929
[6]   A numerical simulation of organ motion and daily setup uncertainties: Implications for radiation therapy [J].
Killoran, JH ;
Kooy, HM ;
Gladstone, DJ ;
Welte, FJ ;
Beard, CJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (01) :213-221
[7]   CALCULATION OF COMPLICATION PROBABILITY FACTORS FOR NON-UNIFORM NORMAL TISSUE IRRADIATION - THE EFFECTIVE VOLUME METHOD [J].
KUTCHER, GJ ;
BURMAN, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 16 (06) :1623-1630
[8]   AN APPLICATION OF DOSE VOLUME HISTOGRAMS TO THE TREATMENT OF INTRAHEPATIC MALIGNANCIES WITH RADIATION-THERAPY [J].
LAWRENCE, TS ;
TESSER, RJ ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (04) :1041-1047
[9]   THE USE OF 3-D-DOSE VOLUME ANALYSIS TO PREDICT RADIATION HEPATITIS [J].
LAWRENCE, TS ;
TENHAKEN, RK ;
KESSLER, ML ;
ROBERTSON, JM ;
LYMAN, JT ;
LAVIGNE, ML ;
BROWN, MB ;
DUROSS, DJ ;
ANDREWS, JC ;
ENSMINGER, WD ;
LICHTER, AS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (04) :781-788
[10]   IMPLEMENTATION OF RANDOM POSITIONING ERROR IN COMPUTERIZED RADIATION TREATMENT PLANNING SYSTEMS AS A RESULT OF FRACTIONATION [J].
LEONG, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (03) :327-334