Accuracy requirements for peptide characterization by monoisotopic molecular mass measurements

被引:102
作者
Zubarev, RA
Hakansson, P
Sundqvist, B
机构
[1] Ion Physics Division, Department for Radiation Sciences, Uppsala University
关键词
D O I
10.1021/ac9604651
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accurately measured monoisotopic mass of a biomolecule can reveal its elemental and, in the case of a biopolymer, its monomer composition, In this work, the limitations of the technique were analyzed in application to peptides, For the currently available level of mass accuracy of about +/-1 ppm, the mass limit for revealing the unique elemental composition of a peptide was found to be 700-800 Da, with the possibility to extend this range as the mass accuracy improves, As for the amino acid composition determination, the principal limit of similar to 500-600 Da cannot be overcome in the general case by instrumental or methodological improvements. It is proposed that, for the peptide characterization, the molecular mass must be determined with sufficient accuracy to rule out a significant fraction of the peptides having the same nominal mass but different elemental and amino acid compositions, An accuracy of +/-1 ppm tvas found to exclude 99% of such peptides and, therefore, ensure a high degree of confidence in peptide characterization.
引用
收藏
页码:4060 / 4063
页数:4
相关论文
共 14 条
[1]  
BEAVIS RC, 1993, ANAL CHEM, V65, P469
[2]   ACCURATE MASS DETERMINATION OF A HIGH-MOLECULAR-WEIGHT PROTEIN USING ELECTROSPRAY-IONIZATION WITH A MAGNETIC-SECTOR INSTRUMENT [J].
DOBBERSTEIN, P ;
SCHROEDER, E .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (09) :861-864
[3]   THE MASS-TO-CHARGE RATIO SCALE [J].
DOUGHERTY, RC ;
MARSHALL, AG ;
EYLER, JR ;
RICHARDSON, DE ;
SMALLEY, RE .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (02) :120-123
[4]   ACCURATE MASSES FOR STRUCTURE CONFIRMATION [J].
GROSS, ML .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (02) :57-57
[5]  
MANN M, 1995, 43 ASMS C MASS SPECT
[6]   DETERMINATION OF OLIGONUCLEOTIDE COMPOSITION FROM MASS SPECTROMETRICALLY MEASURED MOLECULAR-WEIGHT [J].
POMERANTZ, SC ;
KOWALAK, JA ;
MCCLOSKEY, JA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (03) :204-209
[7]   FRACTIONAL MASS VALUES OF LARGE MOLECULES [J].
POMERANTZ, SC ;
MCCLOSKEY, JA .
ORGANIC MASS SPECTROMETRY, 1987, 22 (05) :251-253
[8]   MONOMER MAPPING - A PC-BASED SOFTWARE TOOL FACILITATING THE DETERMINATION OF MONOMER COMPOSITIONS FROM MASS-SPECTROMETRIC MOLECULAR-WEIGHT DATA [J].
VANSETTEN, DC ;
VANDEWERKEN, G .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (11) :917-919
[9]   A SCREENED ELECTROSTATIC ION TRAP FOR ENHANCED MASS RESOLUTION, MASS ACCURACY, REPRODUCIBILITY, AND UPPER MASS LIMIT IN FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
WANG, M ;
MARSHALL, AG .
ANALYTICAL CHEMISTRY, 1989, 61 (11) :1288-1293
[10]   ISOTOPIC DISTRIBUTIONS IN MASS-SPECTRA OF LARGE MOLECULES [J].
YERGEY, J ;
HELLER, D ;
HANSEN, G ;
COTTER, RJ ;
FENSELAU, C .
ANALYTICAL CHEMISTRY, 1983, 55 (02) :353-356