Determination of selected polychlorinated biphenyls in soil by miniaturised ultrasonic solvent extraction and gas chromatography-mass-selective detection

被引:52
作者
Aydin, Mehmet Emin [1 ]
Tor, Ali [1 ]
Ozcan, Senar [1 ]
机构
[1] Selcuk Univ, Dept Environm Engn, TR-42031 Konya, Turkey
关键词
micro-scale extraction; ultrasonic solvent extraction; polychlorinated biphenyls; soil; factorial design;
D O I
10.1016/j.aca.2006.06.050
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
Miniaturised ultrasonic solvent extraction procedure was developed for the determination of selected polychlorinated biphenyls (PCBs) in soil samples by gas chromatography-mass-selective detection by using 2(3) factorial experimental design. Recoveries of PCBs from fortified soil samples are over 90% for three different fortification levels between 40 and 120 mu g kg(-1), and relative standard deviations of the recoveries are below 7%. The limits of detection (LODs) ranged from 0.003 to 0.006 mu g kg(-1). The performance of the proposed method was compared to traditional shake flask extraction method on the spiked real soil sample and extraction methods showed comparable efficiencies. Proposed miniaturised ultrasonic solvent extraction offers several advantages, i.e., reducing sample requirement for measurement of target compound, less solvent consumption and reducing the costs associated with solvent purchase and waste disposal. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:232 / 237
页数:6
相关论文
共 56 条
[1]
Ultrasonic extraction as a sample preparation technique for elemental analysis by atomic spectrometry [J].
Ashley, K ;
Andrews, RN ;
Cavazos, L ;
Demange, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (10) :1147-1153
[2]
*ATSDR, 2000, TOX PROF POL BIPH PC, P447
[3]
Ultrasonic solvent extraction of pesticides from soil [J].
Babic, S ;
Petrovic, M ;
Kastelan-Macan, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 823 (1-2) :3-9
[4]
Persistent organochlorine residues in sediments along the coast of mid-Black Sea region of Turkey [J].
Bakan, G ;
Ariman, S .
MARINE POLLUTION BULLETIN, 2004, 48 (11-12) :1031-1039
[5]
Improved ultrasonic extraction procedure for the determination of polycyclic aromatic hydrocarbons in sediments [J].
Banjoo, DR ;
Nelson, PK .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1066 (1-2) :9-18
[6]
EXPERIMENTAL-DESIGN APPROACH FOR THE EXTRACTION OF POLYCYCLIC AROMATIC-HYDROCARBONS FROM SOIL USING SUPERCRITICAL CARBON-DIOXIDE [J].
BARNABAS, IJ ;
DEAN, JR ;
TOMLINSON, WR ;
OWEN, SP .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2064-2069
[7]
Batarseh MI, 2003, FRESEN ENVIRON BULL, V12, P979
[8]
Summarizing the effectiveness of supercritical fluid extraction of polycyclic aromatic hydrocarbons from natural matrix environmental samples [J].
Benner, BA .
ANALYTICAL CHEMISTRY, 1998, 70 (21) :4594-4601
[9]
Comparison of different drying, extraction and detection techniques for the determination of priority polycyclic aromatic hydrocarbons in background contaminated soil samples [J].
Berset, JD ;
Ejem, M ;
Holzer, R ;
Lischer, P .
ANALYTICA CHIMICA ACTA, 1999, 383 (03) :263-275
[10]
Pressurised liquid extraction of persistent organic pollutants in environmental analysis [J].
Björklund, E ;
Nilsson, T ;
Bowadt, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (07) :434-445