Quantitative material characterization from multi-energy photon counting CT

被引:57
作者
Alessio, Adam M. [1 ]
MacDonald, Lawrence R. [1 ]
机构
[1] Univ Washington, Seattle, WA 98105 USA
基金
美国国家卫生研究院;
关键词
material decomposition; photon counting detector; multi-energy CT; plaque imaging; COMPUTED-TOMOGRAPHY; ENERGY; DETECTORS;
D O I
10.1118/1.4790692
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To quantify the concentration of soft-tissue components of water, fat, and calcium through the decomposition of the x-ray spectral signatures in multi-energy CT images. Methods: Decomposition of dual-energy and multi-energy x-ray data into basis materials can be performed in the projection domain, image domain, or during image reconstruction. In this work, the authors present methodology for the decomposition of multi-energy x-ray data in the image domain for the application of soft-tissue characterization. To demonstrate proof-of-principle, the authors apply several previously proposed methods and a novel content-aware method to multi-energy images acquired with a prototype photon counting CT system. Data from phantom and ex vivo specimens are evaluated. Results: The number and type of materials in a region can be limited based on a priori knowledge or classification strategies. The proposed difference classifier successfully classified the image into air only, water+fat, water+fat+iodine, and water+calcium regions. Then, the content-aware material decomposition based on weighted least-square optimization generated quantitative maps of concentration. Bias in the estimation of the concentration of water and oil components in a phantom study was <0.10 +/- 0.15 g/cc on average. Decomposition of ex vivo carotid endarterectomy specimens suggests the presence of water, lipid, and calcium deposits in the plaque walls. Conclusions: Initial application of the proposed methodology suggests that it can decompose multi-energy CT images into quantitative maps of water, adipose, iodine, and calcium concentrations. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:8
相关论文
共 20 条
[1]
ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]
Barreto Mitya, 2008, J Cardiovasc Comput Tomogr, V2, P234, DOI 10.1016/j.jcct.2008.05.146
[3]
Science to Practice: Can CT Be Performed for Multicolor Molecular Imaging? [J].
Bulte, Jeff W. M. .
RADIOLOGY, 2010, 256 (03) :675-676
[4]
Image-based spectral distortion correction for photon-counting x-ray detectors [J].
Ding, Huanjun ;
Molloi, Sabee .
MEDICAL PHYSICS, 2012, 39 (04) :1864-1876
[5]
ENGLER P, 1990, MATER EVAL, V48, P623
[6]
CORONARY PLAQUE DISRUPTION [J].
FALK, E ;
SHAH, PK ;
FUSTER, V .
CIRCULATION, 1995, 92 (03) :657-671
[7]
Multienergy Photon-counting K-edge Imaging: Potential for Improved Luminal Depiction in Vascular Imaging [J].
Feuerlein, Sebastian ;
Roessl, Ewald ;
Proksa, Roland ;
Martens, Gerhard ;
Klass, Oliver ;
Jeltsch, Martin ;
Rasche, Volker ;
Brambs, Hans-Juergen ;
Hoffmann, Martin H. K. ;
Schlomka, Jens-Peter .
RADIOLOGY, 2008, 249 (03) :1010-1016
[8]
Least squares parameter estimation methods for material decomposition with energy discriminating detectors [J].
Le, Huy Q. ;
Molloi, Sabee .
MEDICAL PHYSICS, 2011, 38 (01) :245-255
[9]
Segmentation and quantification of materials with energy discriminating computed tomography: A phantom study [J].
Le, Huy Q. ;
Molloi, Sabee .
MEDICAL PHYSICS, 2011, 38 (01) :228-237
[10]
Noise reduction in spectral CT: Reducing dose and breaking the trade-off between image noise and energy bin selection [J].
Leng, Shuai ;
Yu, Lifeng ;
Wang, Jia ;
Fletcher, Joel G. ;
Mistretta, Charles A. ;
McCollough, Cynthia H. .
MEDICAL PHYSICS, 2011, 38 (09) :4946-4957