Noise reduction in spectral CT: Reducing dose and breaking the trade-off between image noise and energy bin selection

被引:105
作者
Leng, Shuai [1 ]
Yu, Lifeng [1 ]
Wang, Jia [1 ]
Fletcher, Joel G. [1 ]
Mistretta, Charles A. [2 ]
McCollough, Cynthia H. [1 ]
机构
[1] Mayo Clin, Coll Med, Dept Radiol, Rochester, MN 55905 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53792 USA
关键词
computerised tomography; image denoising; image reconstruction; medical image processing; PHOTON-COUNTING DETECTORS; PIXEL READOUT CHIP; X-RAY-DETECTORS; COMPUTED-TOMOGRAPHY; PULSE PILEUP; RESOLVED CT; PERFORMANCE; MEDIPIX2; DIFFERENTIATION; FEASIBILITY;
D O I
10.1118/1.3609097
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: Our purpose was to reduce image noise in spectral CT by exploiting data redundancies in the energy domain to allow flexible selection of the number, width, and location of the energy bins. Methods: Using a variety of spectral CT imaging methods, conventional filtered backprojection (FBP) reconstructions were performed and resulting images were compared to those processed using a Local HighlY constrained backPRojection Reconstruction (HYPR-LR) algorithm. The mean and standard deviation of CT numbers were measured within regions of interest (ROIs), and results were compared between FBP and HYPR-LR. For these comparisons, the following spectral CT imaging methods were used:(i) numerical simulations based on a photon-counting, detector-based CT system, (ii) a photon-counting, detector-based micro CT system using rubidium and potassium chloride solutions, (iii) a commercial CT system equipped with integrating detectors utilizing tube potentials of 80, 100, 120, and 140 kV, and (iv) a clinical dual-energy CT examination. The effects of tube energy and energy bin width were evaluated appropriate to each CT system. Results: The mean CT number in each ROI was unchanged between FBP and HYPR-LR images for each of the spectral CT imaging scenarios, irrespective of bin width or tube potential. However, image noise, as represented by the standard deviation of CT numbers in each ROI, was reduced by 36%-76%. In all scenarios, image noise after HYPR-LR algorithm was similar to that of composite images, which used all available photons. No difference in spatial resolution was observed between HYPR-LR processing and FBP. Dual energy patient data processed using HYPR-LR demonstrated reduced noise in the individual, low-and high-energy images, as well as in the material-specific basis images. Conclusions: Noise reduction can be accomplished for spectral CT by exploiting data redundancies in the energy domain. HYPR-LR is a robust method for reducing image noise in a variety of spectral CT imaging systems without losing spatial resolution or CT number accuracy. This method improves the flexibility to select energy bins in the manner that optimizes material identification and separation without paying the penalty of increased image noise or its corollary, increased patient dose. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3609097]
引用
收藏
页码:4946 / 4957
页数:12
相关论文
共 59 条
[1]
Comparison of dual energy detector system performance [J].
Alvarez, RE ;
Seibert, JA ;
Thompson, SK .
MEDICAL PHYSICS, 2004, 31 (03) :556-565
[2]
ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[3]
Characterization of a mammographic system based on single photon counting pixel arrays coupled to GaAs x-ray detectors [J].
Amendolia, S. R. ;
Bisogni, M. G. ;
Delogu, P. ;
Fantacci, M. E. ;
Paternoster, G. ;
Rosso, V. ;
Stefanini, A. .
MEDICAL PHYSICS, 2009, 36 (04) :1330-1339
[4]
At the frontiers of digital mammography: SYRMEP [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Tromba, G ;
Vacchi, A ;
Vallazza, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :529-533
[5]
Bacani AK., 2009, Rheumatol Int
[6]
The medipix3 prototype, a pixel readout chip working in single photon counting mode with improved spectrometric performance [J].
Ballabriga, R. ;
Campbell, M. ;
Heijne, E. H. M. ;
Llopart, X. ;
Tlustos, L. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) :1824-1829
[7]
Barber W.C., 2009, P SPIE MEDICAL IMAGI, V7258, P725824, DOI [DOI 10.1117/12.813915, 10.1117/12.813915]
[8]
Computed tomography using the Medipix1 chip [J].
Bert, C ;
Niederlöhner, D ;
Giersch, J ;
Pfeiffer, KF ;
Anton, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3) :240-250
[9]
An application specific integrated circuit and data acquisition system for digital X-ray imaging [J].
Beuville, E ;
Cederstrom, B ;
Danielsson, M ;
Luo, L ;
Nygren, D ;
Oltman, E ;
Vestlund, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 406 (02) :337-342
[10]
High resolution X-ray imaging using a silicon strip detector [J].
Beuville, E ;
Cahn, R ;
Cederström, B ;
Danielsson, M ;
Hall, A ;
Hasegawa, B ;
Luo, L ;
Lundqvist, M ;
Nygren, D ;
Oltman, E ;
Walton, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) :3059-3063