At the frontiers of digital mammography: SYRMEP

被引:26
作者
Arfelli, F
Bonvicini, V
Bravin, A
Cantatore, G
Castelli, E
Dalla Palma, L
Di Michiel, M
Longo, R
Olivo, A
Pani, S
Pontoni, D
Poropat, P
Prest, M [1 ]
Rashevsky, A
Tromba, G
Vacchi, A
Vallazza, E
机构
[1] Univ Trieste, Dipartimento Fis, I-34012 Trieste, Italy
[2] INFN, I-34012 Trieste, Italy
[3] Soc Sincrotrone, Trieste, Italy
[4] Ist Radiol, Trieste, Italy
关键词
D O I
10.1016/S0168-9002(97)01309-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The SYRMEP (SYnchrotron Radiation for MEdical Physics) collaboration is presently taking data at a beamline at the synchrotron ELETTRA in Trieste to study the performances of a digital silicon pixel imaging system for mammography. Images are obtained with a scanning technique in the energy range 15-30 keV. The readout electronics operates in a single photon counting mode with a photon rate of about 10(6)/(mm(2) s), which is still 4 times lower than the maximum rate reachable with the present beamline configuration. Two different detector layouts have been designed, the first one consisting of a single-layer silicon microstrip detector positioned edge-on with respect to the beam, and the second innovative one represented by a matrix of these detectors stacked to cover the full beam dimension (100 x 4 mm(2)). We present here the results obtained with a single-layer detector and a double-layer detector (both 5 cm wide) with mammographic phantoms and human breast tissue. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:529 / 533
页数:5
相关论文
共 10 条
[1]  
ANTONUK LE, 1993, SPIE, V1896, P18
[2]   A pixel-like matrix for digital mammography [J].
Arfelli, F ;
Barbiellini, G ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
DiMichiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Tomasini, F ;
Vacchi, A ;
Tromba, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :402-405
[3]   SYRMEP front-end and read-out electronics [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Cristaudo, P ;
Di Michiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Tomasini, F ;
Tromba, G ;
Vacchi, A ;
Vallazza, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :351-353
[4]   New developments in the field of silicon detectors for digital radiology [J].
Arfelli, F ;
Barbiellini, G ;
Bonvicini, V ;
Cantatore, G ;
Castelli, E ;
DiMichiel, M ;
Longo, R ;
Olivo, A ;
Poropat, P ;
Prest, M ;
Tomasini, F ;
Tromba, G ;
Vacchi, A ;
Zampa, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3) :508-513
[5]   SILICON X-RAY-DETECTOR - FOR SYNCHROTRON-RADIATION DIGITAL RADIOLOGY [J].
ARFELLI, F ;
BARBIELLINI, G ;
CANTATORE, G ;
CASTELLI, E ;
CRISTAUDO, P ;
DALLAPALMA, L ;
DIMICHIEL, M ;
LONGO, R ;
POROPAT, P ;
ROSEI, R ;
SESSA, M ;
TOMASINI, F ;
TROMBA, G ;
VACCHI, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :366-370
[6]   Design and evaluation of AC-coupled, FOXFET-biased, ''edge-on'' silicon strip detectors for X-ray imaging [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Burger, P ;
Cantatore, G ;
Castelli, E ;
DiMichiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Tromba, G ;
Vacchi, A ;
Zampa, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 385 (02) :311-320
[7]  
*CEC, 1990, QUAL CRIT DIAGN RAD
[8]  
COLLEDANI C, 1996, 9604 LEPSI
[9]   X-ray imaging with amorphous selenium: Optimal spectra for digital mammography [J].
Fahrig, R ;
Rowlands, JA ;
Yaffe, MJ .
MEDICAL PHYSICS, 1996, 23 (04) :557-567
[10]   DYNAMIC-RANGE REQUIREMENTS IN DIGITAL MAMMOGRAPHY [J].
MAIDMENT, ADA ;
FAHRIG, R ;
YAFFE, MJ .
MEDICAL PHYSICS, 1993, 20 (06) :1621-1633