Optimization and evaluation of varied line spacing plane grating monochromators for third-generation synchrotron radiation sources

被引:11
作者
Koike, M [1 ]
Namioka, T [1 ]
机构
[1] OFF NAVAL RES,ASIAN OFF,MINATO KU,TOKYO 106,JAPAN
关键词
D O I
10.1016/0368-2048(96)02981-7
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Grazing incidence objective Monk-Gillieson type varied line spacing plane grating monochromators with a magnification of similar to 1/10 have been designed by means of the hybrid method that takes advantages of both the ray-tracing and analytic methods. The resolving power of two monochromators thus designed was assessed experimentally at a bending magnet of the Advanced Light Source, Lawrence Berkeley National Laboratory and found to be similar to 6000 and > 10000 both at 401 eV. These values were well agreed with those estimated by ray tracing that takes into account the slope errors of the optical components. The effect of the thermal deformation of the optical components on the resolving power was simulated. Also discussed are the versatility of the designed monochromators and an improved design with a wide wavelength scanning range of 0.5-10 nm.
引用
收藏
页码:303 / 308
页数:6
相关论文
共 25 条
[1]   VARIABLE GROOVE-SPACED GRATING MONOCHROMATOR FOR SOFT-X-RAY EMISSION-SPECTROSCOPY ST CAMD/LSU [J].
ASFAW, A ;
EDERER, DL ;
ZHOU, L ;
LIN, L ;
OSBORN, K ;
CALLCOTT, TA ;
MIYANO, KE ;
MORIKAWA, E .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1627-1629
[2]  
BEGUIRISTAIN R, 1993, P SOC PHOTO-OPT INS, V2011, P559
[3]   A NEW SPECTROGRAPHIC DIFFRACTION GRATING MOUNTING [J].
GILLIESON, AHCP .
JOURNAL OF SCIENTIFIC INSTRUMENTS AND OF PHYSICS IN INDUSTRY, 1949, 26 (10) :335-339
[4]  
HARADA T, 1984, P SOC PHOTO-OPT INS, V503, P146
[5]  
Hettrick M. C., 1986, AIP Conference Proceedings, P237, DOI 10.1063/1.35993
[6]   RESOLVING POWER OF 35,000 (5-MA) IN THE EXTREME ULTRAVIOLET EMPLOYING A GRAZING-INCIDENCE SPECTROMETER [J].
HETTRICK, MC ;
UNDERWOOD, JH ;
BATSON, PJ ;
ECKART, MJ .
APPLIED OPTICS, 1988, 27 (02) :200-202
[7]   HIGH-RESOLUTION GRATINGS FOR THE SOFT-X-RAY [J].
HETTRICK, MC .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3) :404-413
[8]   SOFT-X-RAY MONOCHROMATOR WITH A VARIED-SPACE PLANE GRATING FOR SYNCHROTRON RADIATION - DESIGN AND EVALUATION [J].
ITOU, M ;
HARADA, T ;
KITA, T .
APPLIED OPTICS, 1989, 28 (01) :146-153
[9]   SOFT-X-RAY MONOCHROMATOR CONFIGURATIONS FOR THE ELETTRA UNDULATORS - A STIGMATIC SX700 [J].
JARK, W .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1241-1246
[10]   STATUS AND PERSPECTIVES OF HIGH-RESOLUTION SPECTROSCOPY IN THE SOFT-X-RAY RANGE [J].
KAINDL, G ;
DOMKE, M ;
LAUBSCHAT, C ;
WESCHKE, E ;
XUE, C .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1234-1240