Daily ultrasound-based image-guided targeting for radiotherapy of upper abdominal malignancies

被引:107
作者
Fuss, M
Salter, BJ
Cavanaugh, SX
Fuss, C
Sadeghi, A
Fuller, CD
Ameduri, A
Hevezi, JM
Herman, TS
Thomas, CR
机构
[1] Univ Texas, Hlth Sci Ctr, Dept Radiat Oncol, San Antonio, TX 78229 USA
[2] Univ Texas, Hlth Sci Ctr, Dept Radiol, San Antonio, TX 78229 USA
[3] Univ Texas, Hlth Sci Ctr, Div Radiol Sci, San Antonio, TX 78229 USA
[4] Canc Therapy & Res Ctr S Texas, San Antonio, TX 78229 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2004年 / 59卷 / 04期
关键词
image-guided targeting; ultrasound; patient positioning; IMRT; liver cancer; pancreatic cancer;
D O I
10.1016/j.ijrobp.2003.12.030
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Development and implementation of a strategy to use a stereotactic ultrasound (US)-based image-guided targeting device (BAT) to align intensity-modulated radiotherapy (IMRT) target volumes accurately in the upper abdomen. Because the outlines of such targets may be poorly visualized by US, we present a method that uses adjacent vascular guidance structures as surrogates for the target position. We assessed the potential for improvement of daily repositioning and the feasibility of daily application. Methods and Materials: A total of 62 patients were treated by sequential tomotherapeutic IMRT between October 2000 and June 2003 for cholangiocarcinoma and gallbladder carcinoma (n = 10), hepatocellular carcinoma (n = 10), liver metastases (n = 11), pancreatic carcinoma (it = 20), neuroblastoma (n = 3), and other abdominal and retroperitoneal tumors (n = 8). The target volumes (TVs) and organs at risk were delineated in contrast-enhanced CT data sets. Additionally, vascular guidance structures in close anatomic relation to the TV, or within the TV, were delineated. Throughout the course of IMRT, US BAT images were acquired during daily treatment positioning. In addition to the anatomic structures typically used for US targeting (e.g., the TV and dose-limiting organs at risk), CT contours of guidance structures were superimposed onto the real-time acquired axial and sagittal US images, and target position adjustments, as indicated by the system, were performed accordingly. We report the BAT-derived distribution of shifts in the three principal room axes compared with a skin-mark-based setup, as well as the time required to perform BAT alignment. The capability of the presented method to improve target alignment was assessed in 15 patients by comparing the organ and fiducial position between the respective treatment simulation CT with a control CT study after US targeting in the CT suite. Results: A total of 1,337 BAT alignments were attempted. US images were not useful in 56 setups (4.2%), mainly because of limited visibility due to daily variations in colonic and gastric air. US imaging was facilitated in intrahepatic tumors and asthenic patients. The mean +/-SD shift from the skin mark position was 4.9 +/- 4.35, 6.0 +/- 5.31, and 6.0 +/- 6.7 mm in the x, y, and z direction, respectively. The mean magnitude vector of three-dimensional alignment correction was 11.4 +/- 7.6 mm. The proportion of daily alignments corrected by a magnitude of >10, >15, and >20 mm was 48.9%, 25.1%, and 12.7%, respectively. The magnitude of shifts in the principal directions, as well as the three-dimensional vector of displacement, was statistically significant (test against the zero hypothesis) at p<0.0001. The guidance structures that were the most valuable for identification of the TV position were the branches of the portal vein, hepatic artery, and dilated bile ducts in intrahepatic lesions and the aorta, celiac trunk, superior mesenteric artery, and extrahepatic aspects of the portal vein system in retroperitoneal and extrahepatic lesions. The mean total setup time was 4.6 min. The correlation of BAT targeting with target setup error assessment in the control CT scans in 15 patients revealed setup error reduction in 14 of 15 alignments. The average setup error reduction, assessed as a reduction in the length of setup error three-dimensional magnitude vector, was 54.4% +/- 26.9%, with an observed mean magnitude of residual setup error of 4.6 +/- 3.4 mm. The sole worsening of an initial setup was by a magnitude of <2 mm. US targeting resulted in statistically significant improvements in patient setup (P = 0.03). Conclusion: Daily US-guided BAT targeting for patients with upper abdominal tumors was feasible in the vast majority of attempted setups. This method of US-based image-guided tumor targeting has been successfully implemented in clinical routine. The observed improved daily repositioning accuracy might allow for individualized reduction of safety margins and optional dose escalation. Compared with the established application of the BAT device for prostate radiotherapy, in which the target can be directly visualized, the TV in the present study was predominantly positioned relative to guidance vascular structures in close anatomic relation. We perceived an enormous potential in improved and individualized patient positioning for fractionated radiotherapy and also for stereotactic extracranial radiotherapy and radiosurgery, especially for tumors of the liver and pancreas. (C) 2004 Elsevier Inc.
引用
收藏
页码:1245 / 1256
页数:12
相关论文
共 18 条
[1]   Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging [J].
Balter, JM ;
Lam, KL ;
McGinn, CJ ;
Lawrence, TS ;
Ten Haken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (04) :939-943
[2]   Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing [J].
Balter, JM ;
TenHaken, RK ;
Lawrence, TS ;
Lam, KL ;
Robertson, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (01) :167-174
[3]   STEREOTAXIC HIGH-DOSE FRACTION RADIATION-THERAPY OF EXTRACRANIAL TUMORS USING AN ACCELERATOR - CLINICAL-EXPERIENCE OF THE FIRST 31 PATIENTS [J].
BLOMGREN, H ;
LAX, I ;
NASLUND, I ;
SVANSTROM, R .
ACTA ONCOLOGICA, 1995, 34 (06) :861-870
[4]  
Ceha HM, 2000, CANCER-AM CANCER SOC, V89, P2222, DOI 10.1002/1097-0142(20001201)89:11<2222::AID-CNCR10>3.0.CO
[5]  
2-V
[6]   Experience of ultrasound-based daily prostate localization [J].
Chandra, A ;
Dong, L ;
Huang, E ;
Kuban, DA ;
O'Neill, L ;
Rosen, I ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02) :436-447
[7]   A comparison of ventilatory prostate movement in four treatment positions [J].
Dawson, LA ;
Litzenberg, DW ;
Brock, KK ;
Sanda, M ;
Sullivan, M ;
Sandler, HM ;
Balter, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02) :319-323
[8]   Daily stereotactic ultrasound prostate targeting: Inter-user variability [J].
Fuss, M ;
Cavanaugh, SX ;
Fuss, C ;
Cheek, DA ;
Salter, BJ .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2003, 2 (02) :161-169
[9]   Extracranial stereotactic radiation therapy:: Set-up accuracy of patients treated for liver metastases [J].
Herfarth, KK ;
Debus, J ;
Lohr, F ;
Bahner, ML ;
Fritz, P ;
Höss, A ;
Schlegel, W ;
Wannenmacher, MF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (02) :329-335
[10]   Stereotactic single-dose radiation therapy of liver tumors:: Results of a phase I/II trial [J].
Herfarth, KK ;
Debus, J ;
Lohr, F ;
Bahner, ML ;
Rhein, B ;
Fritz, P ;
Höss, A ;
Schlegel, W ;
Wannenmacher, MF .
JOURNAL OF CLINICAL ONCOLOGY, 2001, 19 (01) :164-170