A comparison of ventilatory prostate movement in four treatment positions

被引:75
作者
Dawson, LA
Litzenberg, DW
Brock, KK
Sanda, M
Sullivan, M
Sandler, HM
Balter, JM
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Surg, Urol Sect, Ann Arbor, MI 48109 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2000年 / 48卷 / 02期
关键词
prostate radiotherapy; organ motion; breathing;
D O I
10.1016/S0360-3016(00)00751-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To ensure target coverage during radiotherapy, all sources of geometric uncertainty in target position must be considered. Movement of the prostate due to breathing has not traditionally been considered in prostate radiotherapy. The purpose of this study is to report the influence of patient orientation and immobilization on prostate movement due to breathing. Methods and Materials: Four patients had radiopaque markers implanted in the prostate. Fluoroscopy was performed in four different positions: prone in alpha cradle, prone with an aquaplast mold, supine on a flat table, and supine with a false table under the buttocks. Fluoroscopic movies were videotaped and digitized, Frames were analyzed using 2D-alignment software to determine the extent of movement of the prostate markers and the skeleton for each position during normal and deep breathing. Results: During normal breathing, maximal movement of the prostate markers was seen in the prone position (cranial-caudal [CC] range: 0.9-5.1 mm; anterior-posterior [AP] range: up to 3.5 mm), In the supine position, prostate movement during normal breathing was less than 1 mm in all directions. Deep breathing resulted in CC movements of 3.8-10.5 mm in the prone position (with and without an aquaplast mold). This range was reduced to 2.0-7.3 mm in the supine position and 0.5-2.1 mm with the use of the false table top. Deep breathing resulted in AP skeletal movements of 2.7-13.1 mm in the prone position, whereas AP skeletal movements in the supine position were negligible. Conclusion: Ventilatory movement of the prostate is substantial in the prone position and is reduced in the supine position. The potential for breathing to influence prostate movement, and thus the dose delivered to the prostate and normal tissues, should be considered when positioning and planning patients for conformal irradiation. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:319 / 323
页数:5
相关论文
共 14 条
[1]   Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing [J].
Balter, JM ;
TenHaken, RK ;
Lawrence, TS ;
Lam, KL ;
Robertson, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (01) :167-174
[2]   Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility [J].
Balter, JM ;
Lam, KL ;
Sandler, HM ;
Littles, JF ;
Bree, RL ;
TenHaken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1281-1286
[3]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[4]   The effect of pressure from the table top and patient position on pelvic organ location in patients with prostate cancer [J].
Bentel, GC ;
Munley, MT ;
Marks, LB ;
Anscher, MS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (01) :247-253
[5]   Estimation of the incidence of late bladder and rectum complications after high-dose (70-78 Gy) conformal radiotherapy for prostate cancer, using dose-volume histograms [J].
Boersma, LJ ;
van den Brink, M ;
Bruce, AM ;
Shouman, T ;
Gras, L ;
te Velde, A ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (01) :83-92
[6]   PROSTATE MOTION DURING STANDARD RADIOTHERAPY AS ASSESSED BY FIDUCIAL MARKERS [J].
CROOK, JM ;
RAYMOND, Y ;
SALHANI, D ;
YANG, H ;
ESCHE, B .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) :35-42
[7]  
DAWSON L, 1998, INT J RADIAT ONCOL, V142, P1155
[8]   Dose escalation with 3D conformal treatment: Five year outcomes, treatment optimization, and future directions [J].
Hanks, GE ;
Hanlon, AL ;
Schultheiss, TE ;
Pinover, WH ;
Movsas, B ;
Epstein, BE ;
Hunt, MA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (03) :501-510
[9]   Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate [J].
Hanley, J ;
Lumley, MA ;
Mageras, GS ;
Sun, J ;
Zelefsky, MJ ;
Leibel, SA ;
Fuks, Z ;
Kutcher, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (02) :435-444
[10]   The effect of patient position and treatment technique in conformal treatment of prostate cancer [J].
McLaughlin, PW ;
Wygoda, A ;
Sahijdak, W ;
Sandler, HM ;
Marsh, L ;
Roberson, P ;
Ten Haken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02) :407-413