The effect of patient position and treatment technique in conformal treatment of prostate cancer

被引:44
作者
McLaughlin, PW [1 ]
Wygoda, A [1 ]
Sahijdak, W [1 ]
Sandler, HM [1 ]
Marsh, L [1 ]
Roberson, P [1 ]
Ten Haken, RK [1 ]
机构
[1] Univ Michigan, Med Ctr, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 45卷 / 02期
关键词
prostate carcinoma; conformal therapy; prostate motion; prone simulation;
D O I
10.1016/S0360-3016(99)00207-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The relative value of prone versus supine positioning and axial versus nonaxial beam arrangements in the treatment of prostate cancer remains controversial. Two critical issues in comparing techniques are: 1) dose to critical normal tissues, and 2) prostate stabilization. Methods and Materials: Ten patients underwent pretreatment CT scans in one supine and two prone positions (flat and angled), To evaluate normal tissue exposure, prostate/seminal vesicle volumes or prostate volumes were expanded 8 mm and covered by the 95% isodose surface by both 6-field axial and 4-field nonaxial techniques. A total of 280 dose-volume histograms (DVHs) were analyzed to evaluate dose to rectal wall and bladder relative to patient position and beam arrangement. A CT scan was repeated in each patient after 5 weeks of treatment. Prostate motion was assessed by comparing early to late scans by three methods: 1) center of mass shift, 2) superior pubic symphysis to anterior prostate distance, and 3) deviation of the posterior surface of the prostate. Results: For prostate (P) or prostate/seminal vesicle (P/SV) treatments, prone flat was;advantageous or equivalent to other positions with regard to rectal sparing. The mechanism of rectal sparing in the prone position may be related to a paradoxical retraction of the rectum against the sacrum, away from the P/SV, Although there was no clear overall preference for beam arrangement, substantial improvements in rectal sparing could be realized for individual patients. In this limited number of patients, there was no convincing evidence prostate position was stabilized by prone relative to supine position. Conclusions: Prone flat positioning was advantageous over other positions and beam arrangements in rectal sparing. This study suggests that patient position is a more critical a factor in conformal therapy than beam arrangement, and may improve the safety of dose escalation. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:407 / 413
页数:7
相关论文
共 34 条
[1]   Three dimensional comparison of blocked arcs vs four and six field conformal treatment of the prostate [J].
Akazawa, PF ;
Roach, M ;
Pickett, B ;
Purser, P ;
Parkinson, D ;
Rathbun, C ;
Margolis, L .
RADIOTHERAPY AND ONCOLOGY, 1996, 41 (01) :83-88
[2]   Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility [J].
Balter, JM ;
Lam, KL ;
Sandler, HM ;
Littles, JF ;
Bree, RL ;
TenHaken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1281-1286
[3]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[4]   Analysis of prostate and seminal vesicle motion: Implications for treatment planning [J].
Beard, CJ ;
Kijewski, P ;
Bussiere, M ;
Gelman, R ;
Gladstone, D ;
Shaffer, K ;
Plunkett, M ;
Costello, P ;
Coleman, CN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (02) :451-458
[5]   PROSTATE MOTION DURING STANDARD RADIOTHERAPY AS ASSESSED BY FIDUCIAL MARKERS [J].
CROOK, JM ;
RAYMOND, Y ;
SALHANI, D ;
YANG, H ;
ESCHE, B .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) :35-42
[6]  
Fraass BA, 1987, USE COMPUTERS RAD TH, P273
[7]   Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate [J].
Hanley, J ;
Lumley, MA ;
Mageras, GS ;
Sun, J ;
Zelefsky, MJ ;
Leibel, SA ;
Fuks, Z ;
Kutcher, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (02) :435-444
[8]   The effects of out-of-plane rotations on two dimensional portal image registration in conformal radiotherapy of the prostate [J].
Hanley, J ;
Mageras, GS ;
Sun, J ;
Kutcher, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1331-1343
[9]   Chronic rectal bleeding after high-dose conformal treatment of prostate cancer warrants modification of existing morbidity scales [J].
Hanlon, AL ;
Schultheiss, TE ;
Hunt, MA ;
Movsas, B ;
Peter, RS ;
Hanks, GE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (01) :59-63
[10]   CALCULATION OF COMPLICATION PROBABILITY FACTORS FOR NON-UNIFORM NORMAL TISSUE IRRADIATION - THE EFFECTIVE VOLUME METHOD [J].
KUTCHER, GJ ;
BURMAN, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 16 (06) :1623-1630