The effects of out-of-plane rotations on two dimensional portal image registration in conformal radiotherapy of the prostate

被引:42
作者
Hanley, J
Mageras, GS
Sun, J
Kutcher, GJ
机构
[1] Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 33卷 / 05期
关键词
image registration; portal imaging; dosimetric consequences;
D O I
10.1016/0360-3016(95)02062-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Rotations of the patient out of the image plane can significantly degrade the accuracy of two-dimensional (2D) image registration. This study determines the magnitude of the geometric errors introduced by 2D image registration as a result of out-of-plane rotations, and analyzes the dosimetric effects of these errors. Methods and Materials: The magnitude of the errors introduced by 2D registration were determined by comparing orthogonal view portal images of a rotated phantom to simulator reference images of the same phantom without rotation. Dosimetric effects were calculated for three-dimensional (3D) conformal prostate treatments by applying the registration errors to patient treatment plans, The calculations were performed using a modified version of the dose calculation software used in our Cancer Center for 3D treatment planning based on computed tomography (CT), A method to detect out-of-plane rotations, specific to pelvic treatments, is introduced that uses the relative displacement of the centers of gravity of the acetabula in lateral images. Results: The inherent uncertainty in the registration algorithm was 0.6 +/- 0.5 mm in translation and 0.7 +/- 0.8 degrees in rotation within the image plane, For a 2 degrees out-of-plane rotation, the errors increase to 2.3 +/- 1.0 mm and 1.2 +/- 1.1 degrees, In some clinically realizable treatment scenarios it was observed that the errors introduced by the registration procedure could result in an overdosing of the rectal wall. The method to detect out-of-plane rotations was found to have an accuracy of better than 1 degrees for rotations of less than 10 degrees. Conclusions: The errors introduced to the patient position by 2D image registration have dosimetrically significant consequences for out-of-plane rotations of 2 degrees or more, However when used in conjunction with the method to detect out-of-plane rotations, 2D registration software was found to cause insignificant dose errors and, thus, become a more reliable and accurate clinical tool.
引用
收藏
页码:1331 / 1343
页数:13
相关论文
共 29 条
[1]   ONLINE REPOSITIONING DURING TREATMENT OF THE PROSTATE - A STUDY OF POTENTIAL LIMITS AND GAINS [J].
BALTER, JM ;
CHEN, GTY ;
PELIZZARI, CA ;
KRISHNASAMY, S ;
RUBIN, S ;
VIJAYAKUMAR, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (01) :137-143
[2]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[3]   A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES [J].
BEL, A ;
VANHERK, M ;
BARTELINK, H ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :253-260
[4]   RADIATION-FIELD EDGE-DETECTION IN PORTAL IMAGES [J].
BIJHOLD, J ;
GILHUIJS, KGA ;
VANHERK, M ;
MEERTENS, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) :1705-1710
[5]   FAST EVALUATION OF PATIENT SET-UP DURING RADIOTHERAPY BY ALIGNING FEATURES IN PORTAL AND SIMULATOR IMAGES [J].
BIJHOLD, J ;
VANHERK, M ;
VIJLBRIEF, R ;
LEBESQUE, JV .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) :1665-1679
[6]   FITTING OF NORMAL TISSUE TOLERANCE DATA TO AN ANALYTIC-FUNCTION [J].
BURMAN, C ;
KUTCHER, GJ ;
EMAMI, B ;
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :123-135
[7]   ROLE OF PORTAL IMAGING IN CLINICAL RADIOTHERAPY - FLORENCE EXPERIENCE [J].
CIONINI, L ;
BUCCIOLINI, M .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :230-236
[8]   INTERACTIVE USE OF ONLINE PORTAL IMAGING IN PELVIC RADIATION [J].
DENEVE, W ;
VANDENHEUVEL, F ;
COGHE, M ;
VERELLEN, D ;
DEBEUKELEER, M ;
ROELSTRAETE, A ;
DEROOVER, P ;
THON, L ;
STORME, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03) :517-524
[9]   DAILY MONITORING AND CORRECTION OF RADIATION-FIELD PLACEMENT USING A VIDEO-BASED PORTAL IMAGING-SYSTEM - A PILOT-STUDY [J].
EZZ, A ;
MUNRO, P ;
PORTER, AT ;
BATTISTA, J ;
JAFFRAY, DA ;
FENSTER, A ;
OSBORNE, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (01) :159-165
[10]   AUTOMATIC ONLINE INSPECTION OF PATIENT SETUP IN RADIATION-THERAPY USING DIGITAL PORTAL IMAGES [J].
GILHUIJS, KGA ;
VANHERK, M .
MEDICAL PHYSICS, 1993, 20 (03) :667-677