A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES

被引:207
作者
BEL, A
VANHERK, M
BARTELINK, H
LEBESQUE, JV
机构
[1] Radiotherapy Department, The Netherlands Cancer Institute (Antoni van Leeuwenhoek Huis), 1066 CX Amsterdam
关键词
RADIATION THERAPY; PORTAL IMAGING; QUALITY CONTROL; PATIENT SET-UP ACCURACY; DECISION RULES; COMPUTER SIMULATION;
D O I
10.1016/0167-8140(93)90255-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The purpose of this study was to establish which level of geometrical accuracy can be obtained during radiotherapy, using portal image analysis, with a minimum number of patient set-up measurements and corrections. A set-up verification and correction procedure using decision rules for improving the set-up of a patient during radiotherapy was investigated by means of a computer simulation. In this simulation study, set-up deviations were assumed to be the sum of random and systematic deviations and Varying ratios of random and systematic deviations were studied. The distribution of random deviations (SD equal to sigma) was assumed to be equal for all patients of a specific treatment site. Set-up deviations are measured during the first N consecutive fractions after the start of the treatment or after a patient set-up correction. A set-up is corrected when the deviation averaged over these measurements is larger than an N-dependent action level. This action level is specified by alpha/root N, in which alpha is a variable initial action level parameter. After the start of the treatment or after each correction, N-max measurements are made to decide on a possible (further) correction. By varying alpha and N-max, the relation between the overall accuracy and the workload has been analyzed. It was possible to obtain a resulting overall accuracy level which is almost independent of the initial distribution of systematic deviations. When the standard deviation Sigma of the distribution of systematic deviations ranges from sigma to 3 sigma, the parameters alpha = 2 sigma and N-max = 2 result in an accuracy with less than 5% of the set-ups larger than 3 sigma. Using these parameters, for Sigma = 2 sigma, 3.2 measurements and 0.9 corrections per patient on average are required. The probability that a patient has to be corrected more than once is 22.5%. A specific set-up with a initial large systematic deviation equal to 4.5 sigma results in an average deviation smaller than 2 sigma with a probability equal to 99%.
引用
收藏
页码:253 / 260
页数:8
相关论文
共 15 条
[1]  
ALTHOF VGM, 1990, 10TH P INT C US COMP, P107
[2]   MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER [J].
BIJHOLD, J ;
LEBESQUE, JV ;
HART, AAM ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) :261-271
[3]   ROUTINE CLINICAL ONLINE PORTAL IMAGING FOLLOWED BY IMMEDIATE FIELD ADJUSTMENT USING A TELE-CONTROLLED PATIENT COUCH [J].
DENEVE, W ;
VANDENHEUVEL, F ;
DEBEUKELEER, M ;
COGHE, M ;
THON, L ;
DEROOVER, P ;
VANLANCKER, M ;
STORME, G .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (01) :45-54
[4]   TIME TREND OF PATIENT SETUP DEVIATIONS DURING PELVIC IRRADIATION USING ELECTRONIC PORTAL IMAGING [J].
ELGAYED, AAH ;
BEL, A ;
VIJLBRIEF, R ;
BARTELINK, H ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 26 (02) :162-171
[5]   DAILY MONITORING AND CORRECTION OF RADIATION-FIELD PLACEMENT USING A VIDEO-BASED PORTAL IMAGING-SYSTEM - A PILOT-STUDY [J].
EZZ, A ;
MUNRO, P ;
PORTER, AT ;
BATTISTA, J ;
JAFFRAY, DA ;
FENSTER, A ;
OSBORNE, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (01) :159-165
[6]   AUTOMATIC ONLINE INSPECTION OF PATIENT SETUP IN RADIATION-THERAPY USING DIGITAL PORTAL IMAGES [J].
GILHUIJS, KGA ;
VANHERK, M .
MEDICAL PHYSICS, 1993, 20 (03) :667-677
[7]   QUALITY-CONTROL OF RADIOTHERAPY DURING PELVIC IRRADIATION [J].
GRIFFITHS, SE ;
KHOURY, GG ;
EDDY, A .
RADIOTHERAPY AND ONCOLOGY, 1991, 20 (03) :203-206
[8]   ACCURACY IN RADIATION-FIELD ALIGNMENT IN HEAD AND NECK-CANCER - A PROSPECTIVE-STUDY [J].
HUIZENGA, H ;
LEVENDAG, PC ;
DEPORRE, PMZR ;
VISSER, AG .
RADIOTHERAPY AND ONCOLOGY, 1988, 11 (02) :181-187
[9]   DETECTION OF SYSTEMATIC PATIENT SETUP ERRORS BY PORTAL FILM ANALYSIS [J].
LEBESQUE, JV ;
BEL, A ;
BIJHOLD, J ;
HART, AAM .
RADIOTHERAPY AND ONCOLOGY, 1992, 23 (03) :198-198
[10]   1ST CLINICAL-EXPERIENCE WITH A NEWLY DEVELOPED ELECTRONIC PORTAL IMAGING DEVICE [J].
MEERTENS, H ;
VANHERK, M ;
BIJHOLD, J ;
BARTELINK, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (05) :1173-1181