AUTOMATIC ONLINE INSPECTION OF PATIENT SETUP IN RADIATION-THERAPY USING DIGITAL PORTAL IMAGES

被引:93
作者
GILHUIJS, KGA
VANHERK, M
机构
[1] Netherlands Cancer Institute Antoni van Leeuwenhoek Huis, Amsterdam
关键词
RADIATION THERAPY; QUALITY ASSURANCE; PORTAL IMAGING; PATTERN RECOGNITION; MATCHING;
D O I
10.1118/1.597016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new method is presented for inspection of patient setup in radiation therapy by automatic comparison of the patient position relative to the beam position in Portal and simulator images. Quantification of patient-setup errors in terms of translation, rotation, and magnification is achieved by chamfer matching, a robust technique to match drawings and images, which is applied to both anatomy outlines and field edges. Applied to field edges, chamfer matching detects and visualizes deviations in field shape. Applied to anatomy outlines, the matching procedure quantifies and visualizes deviations in patient position relative to the radiation field. To test the method and to judge its feasibility, its behavior for four hundred different patient-setup deviations, which were simulated in four clinical images, was examined. These images show a top view of the pelvic region. The performance was measured in terms of accuracy and success rate for numerous cost functions and distance codings associated with the chamfer matching procedure An average accuracy of 1.8 mm was found, a success rate of 90%, and an average overall computation time of 3 s on a 486 microcomputer. The whole analysis procedure is fast enough to allow on-line application.
引用
收藏
页码:667 / 677
页数:11
相关论文
共 22 条
[1]  
BALTER J, 1990, INT J RADIAT ONCOL, V19, P86
[2]   MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER [J].
BIJHOLD, J ;
LEBESQUE, JV ;
HART, AAM ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) :261-271
[3]   RADIATION-FIELD EDGE-DETECTION IN PORTAL IMAGES [J].
BIJHOLD, J ;
GILHUIJS, KGA ;
VANHERK, M ;
MEERTENS, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) :1705-1710
[4]   FAST EVALUATION OF PATIENT SET-UP DURING RADIOTHERAPY BY ALIGNING FEATURES IN PORTAL AND SIMULATOR IMAGES [J].
BIJHOLD, J ;
VANHERK, M ;
VIJLBRIEF, R ;
LEBESQUE, JV .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) :1665-1679
[5]  
Borgefors G., 1984, Seventh International Conference on Pattern Recognition (Cat. No. 84CH2046-1), P1175
[6]  
FRITSCH DS, 1992, MED PHYS, V19, P1134
[7]  
Gonzales R., 1987, READING
[8]   STUDY OF TREATMENT VARIATION IN THE RADIOTHERAPY OF HEAD AND NECK TUMORS USING A FIBEROPTIC ONLINE RADIOTHERAPY IMAGING-SYSTEM [J].
HALVERSON, KJ ;
LEUNG, TC ;
PELLET, JB ;
GERBER, RL ;
WEINHOUS, MS ;
WONG, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (05) :1327-1336
[9]   INVESTIGATION OF AN FFT-BASED CORRELATION TECHNIQUE FOR VERIFICATION OF RADIATION TREATMENT SETUP [J].
JONES, SM ;
BOYER, AL .
MEDICAL PHYSICS, 1991, 18 (06) :1116-1125
[10]   OPTIMIZATION BY SIMULATED ANNEALING [J].
KIRKPATRICK, S ;
GELATT, CD ;
VECCHI, MP .
SCIENCE, 1983, 220 (4598) :671-680