TIME TREND OF PATIENT SETUP DEVIATIONS DURING PELVIC IRRADIATION USING ELECTRONIC PORTAL IMAGING

被引:81
作者
ELGAYED, AAH [1 ]
BEL, A [1 ]
VIJLBRIEF, R [1 ]
BARTELINK, H [1 ]
LEBESQUE, JV [1 ]
机构
[1] NETHERLANDS CANC INST,ANTONI VAN LEEUWENHOEK HUIS,DEPT RADIOTHERAPY,PLESMANLAAN 121,1066 CX AMSTERDAM,NETHERLANDS
关键词
RADIOTHERAPY; PORTAL IMAGING; PATIENT SETUP ERROR; PELVIC IRRADIATION; RECTAL CARCINOMA; PROSTATE CARCINOMA;
D O I
10.1016/0167-8140(93)90098-S
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
An electronic portal imaging device (EPID) was used to detect patient setup displacement during the course of a 3-field pelvic irradiation of two groups of patients: 10 rectal and 10 prostate carcinomas. These patients were irradiated with conventional treatment techniques in routine clinical practice. A total of 469 portal images and 60 simulator films were used to determine the values of setup deviations in the X- Y- and Z-directions of a fixed coordinate system, corresponding to the medio-lateral, cranio-caudal and antero-posterior direction, respectively. The absolute displacement averaged over all setups and patients ranged between 0.4 mm and 1.4 mm with a standard deviation (S.D.) of 1.6-3.9 mm. The overall distribution along each direction could be separated into a distribution of random deviations (S.D.s ranging from 1.2 to 2.8 mm) around the mean deviation of each patient and a distribution of the means themselves: the distribution of systematic deviations (S.D.s ranging from 1.0 to 2.6 mm). Significant gradual displacement as a function of time was detected in 5 out of the 20 patients, 2 in the rectum and 3 in the prostate group. This ''time trend'' was found along each of the 3 directions specified. The magnitude of the time-dependent displacement throughout the course of treatment ranged between 4 and 11 mm. It can be concluded that for treatments requiring a high level of precision, portal images should be made and analyzed during the whole treatment course in order to detect and correct significant time trends.
引用
收藏
页码:162 / 171
页数:10
相关论文
共 29 条
[1]   MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER [J].
BIJHOLD, J ;
LEBESQUE, JV ;
HART, AAM ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) :261-271
[2]   RADIATION-FIELD EDGE-DETECTION IN PORTAL IMAGES [J].
BIJHOLD, J ;
GILHUIJS, KGA ;
VANHERK, M ;
MEERTENS, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) :1705-1710
[3]   FAST EVALUATION OF PATIENT SET-UP DURING RADIOTHERAPY BY ALIGNING FEATURES IN PORTAL AND SIMULATOR IMAGES [J].
BIJHOLD, J ;
VANHERK, M ;
VIJLBRIEF, R ;
LEBESQUE, JV .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) :1665-1679
[4]   A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS) [J].
BOYER, AL ;
ANTONUK, L ;
FENSTER, A ;
VANHERK, M ;
MEERTENS, H ;
MUNRO, P ;
REINSTEIN, LE ;
WONG, J .
MEDICAL PHYSICS, 1992, 19 (01) :1-16
[5]   WEEKLY LOCALIZATION FILMS AND DETECTION OF FIELD PLACEMENT ERRORS [J].
BYHARDT, RW ;
COX, JD ;
HORNBURG, A ;
LIERMANN, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (9-10) :881-887
[6]   DAILY MONITORING AND CORRECTION OF RADIATION-FIELD PLACEMENT USING A VIDEO-BASED PORTAL IMAGING-SYSTEM - A PILOT-STUDY [J].
EZZ, A ;
MUNRO, P ;
PORTER, AT ;
BATTISTA, J ;
JAFFRAY, DA ;
FENSTER, A ;
OSBORNE, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (01) :159-165
[7]  
GILHUIJS KGA, 1993, IN PRESS MED PHYS
[8]   IMMOBILIZATION ERROR - SOME THEORETICAL CONSIDERATIONS [J].
GOITEIN, M ;
BUSSE, J .
RADIOLOGY, 1975, 117 (02) :407-412
[9]   QUALITY-CONTROL OF RADIOTHERAPY DURING PELVIC IRRADIATION [J].
GRIFFITHS, SE ;
KHOURY, GG ;
EDDY, A .
RADIOTHERAPY AND ONCOLOGY, 1991, 20 (03) :203-206
[10]   QUALITY-CONTROL IN RADIOTHERAPY - THE REDUCTION OF FIELD PLACEMENT ERRORS [J].
GRIFFITHS, SE ;
PEARCEY, RG ;
THOROGOOD, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (10) :1583-1588