TIME TREND OF PATIENT SETUP DEVIATIONS DURING PELVIC IRRADIATION USING ELECTRONIC PORTAL IMAGING

被引:81
作者
ELGAYED, AAH [1 ]
BEL, A [1 ]
VIJLBRIEF, R [1 ]
BARTELINK, H [1 ]
LEBESQUE, JV [1 ]
机构
[1] NETHERLANDS CANC INST,ANTONI VAN LEEUWENHOEK HUIS,DEPT RADIOTHERAPY,PLESMANLAAN 121,1066 CX AMSTERDAM,NETHERLANDS
关键词
RADIOTHERAPY; PORTAL IMAGING; PATIENT SETUP ERROR; PELVIC IRRADIATION; RECTAL CARCINOMA; PROSTATE CARCINOMA;
D O I
10.1016/0167-8140(93)90098-S
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
An electronic portal imaging device (EPID) was used to detect patient setup displacement during the course of a 3-field pelvic irradiation of two groups of patients: 10 rectal and 10 prostate carcinomas. These patients were irradiated with conventional treatment techniques in routine clinical practice. A total of 469 portal images and 60 simulator films were used to determine the values of setup deviations in the X- Y- and Z-directions of a fixed coordinate system, corresponding to the medio-lateral, cranio-caudal and antero-posterior direction, respectively. The absolute displacement averaged over all setups and patients ranged between 0.4 mm and 1.4 mm with a standard deviation (S.D.) of 1.6-3.9 mm. The overall distribution along each direction could be separated into a distribution of random deviations (S.D.s ranging from 1.2 to 2.8 mm) around the mean deviation of each patient and a distribution of the means themselves: the distribution of systematic deviations (S.D.s ranging from 1.0 to 2.6 mm). Significant gradual displacement as a function of time was detected in 5 out of the 20 patients, 2 in the rectum and 3 in the prostate group. This ''time trend'' was found along each of the 3 directions specified. The magnitude of the time-dependent displacement throughout the course of treatment ranged between 4 and 11 mm. It can be concluded that for treatments requiring a high level of precision, portal images should be made and analyzed during the whole treatment course in order to detect and correct significant time trends.
引用
收藏
页码:162 / 171
页数:10
相关论文
共 29 条
[21]   ERRORS IN REPRODUCING PELVIC RADIATION PORTALS [J].
RICHARDS, MJS ;
BUCHLER, DA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1977, 2 (9-10) :1017-1019
[22]   POTENTIAL IMPROVEMENT IN THE RESULTS OF IRRADIATION FOR PROSTATE CARCINOMA USING IMPROVED DOSE DISTRIBUTION [J].
SANDLER, HM ;
MCSHAN, DL ;
LICHTER, AS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (02) :361-367
[23]   SOLUTION TO TREATMENT PLANNING PROBLEMS USING COORDINATE TRANSFORMATIONS [J].
SIDDON, RL .
MEDICAL PHYSICS, 1981, 8 (06) :766-774
[24]   A MATRIX IONIZATION-CHAMBER IMAGING DEVICE FOR ONLINE PATIENT SETUP VERIFICATION DURING RADIOTHERAPY [J].
VANHERK, M ;
MEERTENS, H .
RADIOTHERAPY AND ONCOLOGY, 1988, 11 (04) :369-378
[25]   ACCURACY IN TANGENTIAL BREAST TREATMENT SET-UP - A PORTAL IMAGING STUDY [J].
VANTIENHOVEN, G ;
LANSON, JH ;
CRABEELS, D ;
HEUKELOM, S ;
MIJNHEER, BJ .
RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) :317-322
[26]   PERFORMANCE OF A PROTOTYPE FLUOROSCOPIC RADIOTHERAPY IMAGING-SYSTEM [J].
VISSER, AG ;
HUIZENGA, H ;
ALTHOF, VGM ;
SWANENBURG, BN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (01) :43-50
[27]  
WHITE JE, 1982, CANCER, V50, P1084, DOI 10.1002/1097-0142(19820915)50:6<1084::AID-CNCR2820500611>3.0.CO
[28]  
2-W
[29]  
1978, ICRU29 REP