Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate

被引:142
作者
Hanley, J [1 ]
Lumley, MA [1 ]
Mageras, GS [1 ]
Sun, J [1 ]
Zelefsky, MJ [1 ]
Leibel, SA [1 ]
Fuks, Z [1 ]
Kutcher, GJ [1 ]
机构
[1] MEM SLOAN KETTERING CANC CTR,DEPT RADIAT ONCOL,NEW YORK,NY 10021
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1997年 / 37卷 / 02期
关键词
image registration; portal imaging; setup errors;
D O I
10.1016/S0360-3016(96)00526-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose/Objective: To determine the spatial distribution of setup errors for patients treated with six-field, three-dimensional (3D) conformal radiation therapy for prostate cancer. Methods and Materials: Port films for 50 patients were analyzed retrospectively. The port films were digitized and compared, using image registration software, to simulator films (representing the ideal treatment position). Patient positioning uncertainty for a given setup was determined using port films from three projections, two obliques, and one lateral. A total of 1239 port films and 300 simulator films were analyzed for the study. Patient position was analyzed for out-of-plane rotations and time trends over the course of treatment. Results: The distribution of systematic setup errors for the 50 patients, defined as the mean patient displacement for the treatment course, had a mean and standard deviation (SD) of (-0.1 +/- 1.9) mm, (0.4 +/- 1.4) mm, and (-0.3 +/- 1.3) mm in the mediolateral (ML), superior-inferior (SI) and anterior-posterior (AP) directions, and (-0.1 +/- 0.2) for rotational errors. The distribution of random setup errors about the mean approximated a normal distribution and the standard deviations for the population of patients in the Mi,, SI, and AP directions, were 2.0 mm, 1.7 mm, and 1.9 mm, respectively. The distribution of out-of-plane rotations had 1 SD of 0.9 degrees and 0.6 degrees about the SI and AP axes. Ten of the 50 patients demonstrated a statistically significant time trend in their setup position resulting in shifts ranging from 2 to 7 mm. Conclusions: The setup verification protocol appears to minimize systematic setup errors to a level that approaches the sensitivity of the image registration technique. The random day to day fluctuations, represented by the average values of the standard deviations, are minor in comparison to the currently used margins, which further emphasizes the effectiveness of this protocol in conjunction with the use of the immobilization device. (C) 1997 Elsevier Science Inc.
引用
收藏
页码:435 / 444
页数:10
相关论文
共 29 条
  • [1] MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS
    BALTER, JM
    SANDLER, HM
    LAM, K
    BREE, RL
    LICHTER, AS
    TENHAKEN, RK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01): : 113 - 118
  • [2] A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES
    BEL, A
    VANHERK, M
    BARTELINK, H
    LEBESQUE, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 253 - 260
  • [3] MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER
    BIJHOLD, J
    LEBESQUE, JV
    HART, AAM
    VIJLBRIEF, RE
    [J]. RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) : 261 - 271
  • [4] RADIATION-FIELD EDGE-DETECTION IN PORTAL IMAGES
    BIJHOLD, J
    GILHUIJS, KGA
    VANHERK, M
    MEERTENS, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) : 1705 - 1710
  • [5] FAST EVALUATION OF PATIENT SET-UP DURING RADIOTHERAPY BY ALIGNING FEATURES IN PORTAL AND SIMULATOR IMAGES
    BIJHOLD, J
    VANHERK, M
    VIJLBRIEF, R
    LEBESQUE, JV
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) : 1665 - 1679
  • [6] ROLE OF PORTAL IMAGING IN CLINICAL RADIOTHERAPY - FLORENCE EXPERIENCE
    CIONINI, L
    BUCCIOLINI, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 230 - 236
  • [7] INTERACTIVE USE OF ONLINE PORTAL IMAGING IN PELVIC RADIATION
    DENEVE, W
    VANDENHEUVEL, F
    COGHE, M
    VERELLEN, D
    DEBEUKELEER, M
    ROELSTRAETE, A
    DEROOVER, P
    THON, L
    STORME, G
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03): : 517 - 524
  • [8] TIME TREND OF PATIENT SETUP DEVIATIONS DURING PELVIC IRRADIATION USING ELECTRONIC PORTAL IMAGING
    ELGAYED, AAH
    BEL, A
    VIJLBRIEF, R
    BARTELINK, H
    LEBESQUE, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 26 (02) : 162 - 171
  • [9] DAILY MONITORING AND CORRECTION OF RADIATION-FIELD PLACEMENT USING A VIDEO-BASED PORTAL IMAGING-SYSTEM - A PILOT-STUDY
    EZZ, A
    MUNRO, P
    PORTER, AT
    BATTISTA, J
    JAFFRAY, DA
    FENSTER, A
    OSBORNE, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (01): : 159 - 165
  • [10] AUTOMATIC ONLINE INSPECTION OF PATIENT SETUP IN RADIATION-THERAPY USING DIGITAL PORTAL IMAGES
    GILHUIJS, KGA
    VANHERK, M
    [J]. MEDICAL PHYSICS, 1993, 20 (03) : 667 - 677