Biomechanical properties of patellar and hamstring graft tibial fixation techniques in anterior cruciate ligament reconstruction - Experimental study with roentgen stereometric analysis

被引:48
作者
Adam, F [1 ]
Pape, D [1 ]
Schiel, K [1 ]
Steimer, O [1 ]
Kohn, D [1 ]
Rupp, S [1 ]
机构
[1] Univ Saarland, Med Ctr, Lab Radiosterometr Anal, RSA,Dept Orthopaed Surg, D-6650 Homburg, Germany
关键词
anterior cruciate ligament; ACL; reconstruction; hamstrings; BPTB-graft; biomechanics; roentgen stereometric analysis; RSA;
D O I
10.1177/0095399703258608
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Reliable fixation of the soft hamstring grafts in ACL reconstruction has been reported as problematic. Hypothesis: The biomechanical properties of patellar tendon (PT) grafts fixed with biodegradable screws (PTBS) are superior compared to quadrupled hamstring grafts fixed with BioScrew (HBS) or Suture-Disc fixation (HSD). Study Design: Controlled laboratory study with roentgen stereometric analysis (RSA). Methods: Ten porcine specimens were prepared for each group. In the PT group, the bone plugs were fixed with a 7 x 25 mm BioScrew. In the hamstring group, four-stranded tendon grafts were anchored within a tibial tunnel of 8 mm diameter either with a 7 x 25 mm BioScrew or eight polyester sutures knotted over a Suture-Disc. The grafts were loaded stepwise, and micromotion of the graft inside the tibial tunnel was measured with RSA. Results: Hamstring grafts failed at lower loads (HBS: 536 N, HSD 445 N) than the PTBS grafts (658 N). Stiffness in the PTBS group was much greater compared to the hamstring groups (3500 N/mm versus HBS = 517 N/mm and HSD = 111 N/mm). Irreversible graft motion after graft loading with 200 N was measured at 0.03 mm (PTBS), 0.38 mm (HBS), and 1.85 mm (HSD). Elasticity for the HSD fixation was measured at 0.67 mm at 100 N and 1.32 mm at 200 N load. Conclusion: Hamstring graft fixation with BioScrew and Suture-Disc displayed less stiffness and early graft motion compared to PTBS fixation. Screw fixation of tendon grafts is superior to Suture-Disc fixation with linkage material since it offers greater stiffness and less graft motion inside the tibial tunnel. Clinical Relevance: Our results revealed graft motion for hamstring fixation with screw or linkage material at loads that occur during rehabilitation. This, in turn, may lead to graft laxity.
引用
收藏
页码:71 / 78
页数:8
相关论文
共 40 条
[1]
Adam F, 2001, ORTHOPADE, V30, P649, DOI 10.1007/s001320170053
[2]
PATELLAR TENDON VERSUS DOUBLED SEMITENDINOSUS AND GRACILIS TENDONS FOR ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION [J].
AGLIETTI, P ;
BUZZI, R ;
ZACCHEROTTI, G ;
DEBIASE, P .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (02) :211-218
[3]
BECKER R, 2000, ARTHOSKOPIE, V13, P314
[4]
BROWN CH, 1993, CLIN SPORT MED, V12, P723
[5]
Quadrupled semitendinosus-gracilis autograft fixation in the femoral tunnel: A comparison between a metal and a bioabsorbable interference screw [J].
Caborn, DNM ;
Coen, M ;
Neef, R ;
Hamilton, D ;
Nyland, J ;
Johnson, DL .
ARTHROSCOPY, 1998, 14 (03) :241-245
[6]
Dahlberg G., 1940, STAT METHODS MED BIO
[7]
MEASUREMENT ERRORS IN ROENTGEN-STEREOPHOTOGRAMMETRIC JOINT-MOTION ANALYSIS [J].
DELANGE, A ;
HUISKES, R ;
KAUER, JMG .
JOURNAL OF BIOMECHANICS, 1990, 23 (03) :259-269
[8]
LAXITY AND GRAFT FIXATION AFTER RECONSTRUCTION OF THE ANTERIOR CRUCIATE LIGAMENT - A ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS OF 11 PATIENTS [J].
FRIDEN, T ;
RYD, L ;
LINDSTRAND, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (01) :80-84
[9]
Mechanical behavior of two hamstring graft constructs for reconstruction of the anterior cruciate ligament [J].
Höher, J ;
Scheffler, SU ;
Withrow, JD ;
Livesay, GA ;
Debski, RE ;
Fu, FH ;
Woo, SLY .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2000, 18 (03) :456-461
[10]
The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: Evaluation using a robotic testing system [J].
Ishibashi, Y ;
Rudy, TW ;
Livesay, GA ;
Stone, JD ;
Fu, FH ;
Woo, SLY .
ARTHROSCOPY, 1997, 13 (02) :177-182