Quadrupled semitendinosus-gracilis autograft fixation in the femoral tunnel: A comparison between a metal and a bioabsorbable interference screw

被引:109
作者
Caborn, DNM [1 ]
Coen, M [1 ]
Neef, R [1 ]
Hamilton, D [1 ]
Nyland, J [1 ]
Johnson, DL [1 ]
机构
[1] Univ Kentucky, Sch Med, Div Orthopaed Surg, Sect Sprts Med,Kentucky Clin K429, Lexington, KY 40536 USA
来源
ARTHROSCOPY | 1998年 / 14卷 / 03期
关键词
anterior cruciate ligament reconstruction; graft fixation;
D O I
10.1016/S0749-8063(98)70138-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although semitendinosus-gracilis (SG) grafts for anterior cruciate ligament reconstruction have many potential benefits, effective fixation remains a challenge. This study assessed differences between the maximum pullout forces needed to detach a quadrupled SG graft from a femoral tunnel when secured by either a metal or a bioabsorbable interference screw. Sixteen paired fresh frozen quadrupled SG autografts (x, 8.4 mm; range, 7-10 mm) from 8 donors were anchored into cadaveric femoral tunnels by either a 7-mm metal or a 7-mm bioabsorbable screw after bone mineral density (BMD) assessment and before undergoing a longitudinal 20 mm/min traction force. Statistical analysis compared BMD (gm/cm(2)), insertional torque (N-m), and maximum load at pullout (N) between screw types. Insertional torques (.28-1.21, N-m range) did not correlate (P > 1.05) to BMD or maximum load at pullout (x +/- S.D.) 242 +/- 90.7 N (metal screw) and 341.1 +/- 162.9 N (bioabsorbable screw). Differences did not exist between the maximum load at pullout for bioabsorbable or metal screw fixation (P = .16). Careful graft preparation, sizing, and matched tunnel placement enables interference fit and fixation capable of reliably withstanding the low-level rehabilitation loads to which the graft is exposed until bony ingrowth occurs.
引用
收藏
页码:241 / 245
页数:5
相关论文
共 32 条
[1]
THE STRENGTH OF ARTIFICIAL LIGAMENT ANCHORAGES - A COMPARATIVE EXPERIMENTAL-STUDY [J].
AMIS, AA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (03) :397-403
[2]
PRELIMINARY-RESULTS OF AN ABSORBABLE INTERFERENCE SCREW [J].
BARBER, FA ;
ELROD, BF ;
MCGUIRE, DA ;
PAULOS, LE .
ARTHROSCOPY, 1995, 11 (05) :537-548
[3]
ANTERIOR CRUCIATE LIGAMENT STRAIN BEHAVIOR DURING REHABILITATION EXERCISES IN-VIVO [J].
BEYNNON, BD ;
FLEMING, BC ;
JOHNSON, RJ ;
NICHOLS, CE ;
RENSTROM, PA ;
POPE, MH .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1995, 23 (01) :24-34
[4]
THE EFFECTS OF DONOR AGE AND STRAIN-RATE ON THE BIOMECHANICAL PROPERTIES OF BONE-PATELLAR TENDON-BONE ALLOGRAFTS [J].
BLEVINS, FT ;
HECKER, AT ;
BIGLER, GT ;
BOLAND, AL ;
HAYES, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (03) :328-333
[5]
THE BIOMECHANICS OF INTERFERENCE SCREW FIXATION OF PATELLAR TENDON ANTERIOR CRUCIATE LIGAMENT GRAFTS [J].
BROWN, CH ;
HECKER, AT ;
HIPP, JA ;
MYERS, ER ;
HAYES, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (06) :880-886
[6]
BUTLER DL, 1987, AAOS INSTR COURSE LE, V36, P173
[7]
OPTIMAL GRAFT FIXATION - THE EFFECT OF GAP SIZE AND SCREW SIZE ON BONE PLUG FIXATION IN ACL RECONSTRUCTION [J].
BUTLER, JC ;
BRANCH, TP ;
HUTTON, WC .
ARTHROSCOPY, 1994, 10 (05) :524-529
[8]
Biomechanical comparison between BioScrew and titanium alloy interference screws for bone-patellar tendon-bone graft fixation in anterior cruciate ligament reconstruction [J].
Caborn, DNM ;
Urban, WP ;
Johnson, DL ;
Nyland, J ;
Pienkowski, D .
ARTHROSCOPY, 1997, 13 (02) :229-232
[9]
CHAMPION AR, 1995, 41 ANN M ORTH RES SO
[10]
Gibson L.J., 1988, Cellular Solids, P316