SHARING TRANSIENT LOADS Causes of unequal transient load sharing in islanded microgrid operation

被引:101
作者
Paquette, Andrew D. [1 ]
Reno, Matthew J. [1 ]
Harley, Ronald G. [1 ,2 ]
Divan, Deepak M. [1 ,2 ]
机构
[1] Georgia Inst Technol, Atlanta, GA 30332 USA
[2] IEEE, Piscataway, NJ USA
关键词
AC; INTERFACE;
D O I
10.1109/MIAS.2013.2288408
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
WHEN INVERTERS IN VOLTAGEcontrol mode are paired with synchronous generators (SGs), they exhibit poor transient load sharing in islanded operation. It is well known that power electronics respond more quickly where the inverter initially picks up the majority of every load step, and the generator's output slowly increases until they reach their steady-state load sharing given by droop settings. This excessive transient power output from the inverter constrains its rating relative to the largest load step and could negatively impact the battery life in battery energy-storage inverters. This article provides a detailed examination of the differences between the frequency-regulation characteristics of inverters and generators to explain, in a novel way, the cause of the poor transient power sharing. The tradeoff between an improved transient load sharing and increased voltage and frequency transients is highlighted, and it is demonstrated that equal transient load sharing can be achieved by emulating an SG using a power hardware-in-the-loop (HIL) approach. Validation is provided by simulation and experimental results. © 2014 IEEE.
引用
收藏
页码:23 / 34
页数:12
相关论文
共 24 条
[1]  
[Anonymous], 2010, PSCAD EMTDC US MAN V
[2]  
Beck H. P., 2007, P EL POW QUAL UT BAR
[3]   Control Methods of Inverter-Interfaced Distributed Generators in a Microgrid System [J].
Chung, Il-Yop ;
Liu, Wenxin ;
Cartes, David A. ;
Collins, Emmanuel G., Jr. ;
Moon, Seung-Il .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (03) :1078-1088
[4]   A phase tracking system for three phase utility interface inverters [J].
Chung, SK .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (03) :431-438
[5]  
De Brabandere K., 2006, THESIS K U LEUVEN BE
[6]   A voltage and frequency droop control method for parallel inverters [J].
De Brabandere, Karel ;
Bolsens, Bruno ;
Van den Keybus, Jeroen ;
Woyte, Achim ;
Driesen, Johan ;
Belmans, Ronnie .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (04) :1107-1115
[7]  
Dewadasa M., 2011, 2011 IEEE POWER ENER, P1, DOI 10.1109/PES.2011.6039273
[8]   A High-Performance Electronic Hardware-in-the-Loop Drive-Load Simulation Using a Linear Inverter (LinVerter) [J].
Grubic, Stefan ;
Amlang, Bernd ;
Schumacher, Walter ;
Wenzel, Andree .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (04) :1208-1216
[9]   Hierarchical Control of Droop-Controlled AC and DC Microgrids-A General Approach Toward Standardization [J].
Guerrero, Josep M. ;
Vasquez, Juan C. ;
Matas, Jose ;
Garci de Vicuna, Luis ;
Castilla, Miguel .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (01) :158-172
[10]   Microgrids [J].
Hatziargyriou, Nikos ;
Asano, Hiroshi ;
Iravani, Reza ;
Marnay, Chris .
IEEE POWER & ENERGY MAGAZINE, 2007, 5 (04) :78-94