Stent-based approach for ventricle-to-coronary artery bypass

被引:26
作者
Boekstegers, P
Raake, P
Al Ghobainy, R
Horstkotte, J
Hinkel, R
Sandner, T
Wichels, R
Meisner, F
Thein, E
March, K
Boehm, D
Reichenspurner, H
机构
[1] Univ Munich, Klinikum Grosshadern, Med Klin 1, Dept Internal Med 1, D-81377 Munich, Germany
[2] Univ Munich, Inst Surg Res, D-8000 Munich, Germany
[3] Univ Hamburg, Hosp Eppendorf, Dept Cardiac Surg, D-20246 Hamburg, Germany
[4] Indiana Univ, Indiana Ctr Vasc Biol & Med, Indianapolis, IN 46204 USA
关键词
arteries; revascularization; shunts; stents;
D O I
10.1161/01.CIR.0000027106.88111.77
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Ventricle-to-coronary artery bypass (VCAB) is an experimental revascularization procedure that provides predominantly systolic instead of diastolic blood flow to a coronary artery. Methods and Results-In a pig model, a stent-based procedure (VSTENT) was developed to create a VCAB. After thoracotomy, a covered VSTENT was implanted between the left ventricle and the left anterior descending coronary artery (LAD). Distal LAD flow, regional myocardial function, and intracoronary pressures were determined at different degrees of LAD stenosis and during complete LAD occlusion. During 3 hours of LAD occlusion, VSTENT preserved net forward flow at 70+/-6% and regional myocardial function at 71+/-8% of baseline. Preservation of net flow was influenced by the positioning of the VSTENT, with higher preservation also under conditions of increased oxygen demand if a "valve-like mechanism" was present during diastole. At a hemodynamically relevant level of LAD stenosis (>70%), systolic inflow was predominant after VSTENT implantation. Changes in mean diastolic intracoronary pressure that resulted from different degrees of LAD stenosis were linearly correlated to net flow after VSTENT implantation (r=0.88; P<0.001). Conclusions-VSTENT for ventricle-to-coronary artery bypass was feasible and preserved 70+/-6% of baseline flow during complete LAD occlusion. The degree of preservation was dependent on the position of the VSTENT creating a valve-like mechanism during diastole. Residual diastolic blood flow through a high-grade LAD stenosis influenced net flow favorably, because diastolic backflow decreased with increasing mean diastolic intracoronary pressure.
引用
收藏
页码:1000 / 1006
页数:7
相关论文
共 13 条
[1]   PRESERVATION OF REGIONAL MYOCARDIAL-FUNCTION AND MYOCARDIAL OXYGEN-TENSION DURING ACUTE-ISCHEMIA IN PIGS - COMPARISON OF SELECTIVE SYNCHRONIZED SUCTION AND RETROINFUSION OF CORONARY VEINS TO SYNCHRONIZED CORONARY VENOUS RETROPERFUSION [J].
BOEKSTEGERS, P ;
PETER, W ;
VONDEGENFELD, G ;
NIENABER, CA ;
ABEND, M ;
REHDERS, TC ;
HABAZETTL, H ;
KAPSNER, T ;
VONLUDINGHAUSEN, M ;
WERDAN, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (02) :459-469
[2]   Myocardial gene transfer by selective pressure-regulated retroinfusion of coronary veins [J].
Boekstegers, P ;
von Degenfeld, G ;
Giehrl, W ;
Heinrich, D ;
Hullin, R ;
Kupatt, C ;
Steinbeck, G ;
Baretton, G ;
Middeler, G ;
Katus, H ;
Franz, WM .
GENE THERAPY, 2000, 7 (03) :232-240
[3]   LEFT-VENTRICULAR SURFACE TISSUE OXYGEN PRESSURES DETERMINED BY OXYGEN SENSITIVE MULTIWIRE ELECTRODES IN PIGS [J].
CONZEN, PF ;
HABAZETTL, H ;
CHRIST, M ;
BAIER, H ;
HOBBHAHN, J ;
VOLLMAR, B ;
PETER, K .
CARDIOVASCULAR RESEARCH, 1991, 25 (03) :207-216
[4]  
GOLDMAN A, 1956, J THORAC SURG, V31, P364
[5]  
Hamada Y, 2001, J CARDIOVASC SURG, V42, P159
[6]   Effects of competitive blood flow on arterial graft patency and diameter - Medium-term postoperative follow-up [J].
Hashimoto, H ;
Isshiki, T ;
Ikari, Y ;
Hara, K ;
Saeki, F ;
Tamura, T ;
Yamaguchi, T ;
Suma, H .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (02) :399-407
[7]  
MASSIMO C, 1957, J THORAC SURG, V34, P257
[8]   POSSIBILITY OF MYOCARDIAL REVASCULARIZATION BY CREATION OF A LEFT VENTRICULOCORONARY ARTERY FISTULA [J].
MUNRO, I ;
ALLEN, P .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1969, 58 (01) :25-&
[9]   MYOCARDIAL-FUNCTION AND TRANSMURAL BLOOD-FLOW DURING CORONARY VENOUS RETROPERFUSION IN PIGS [J].
OH, BH ;
VOLPINI, M ;
KAMBAYASHI, M ;
MURATA, K ;
ROCKMAN, HA ;
KASSAB, GS ;
ROSS, J .
CIRCULATION, 1992, 86 (04) :1265-1279
[10]   A new sample-processing unit for the fluorescent microsphere method [J].
Raab, S ;
Thein, E ;
Harris, AG ;
Messmer, K .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 276 (05) :H1801-H1806