The IAEA/WHO TLD postal programme for radiotherapy hospitals

被引:124
作者
Izewska, J [1 ]
Andreo, P [1 ]
机构
[1] Int Atom Energy Agcy, Dosimetry & Med Radiat Phys, A-1400 Vienna, Austria
关键词
QA in radiotherapy; TLD audits; beam output checks; high energy photons;
D O I
10.1016/S0167-8140(99)00164-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Since 1969 the International Atomic Energy Agency (IAEA), together with the World Health Organization (WHO). has performed postal TLD audits to verify the calibration of radiotherapy beams in developing countries. Materials and methods: A number of changes have recently been implemented to improve the efficiency of the IAEA/WHO TLD programme. The IAEA has increased the number of participants and reduced significantly the total turn-around time to provide results to the hospitals within the shortest possible time following the TLD irradiations. The IAEA has established a regular follow-up programme for hospitals with results outside acceptance limits of +/-5%. Results: The IAEA has. over 30 years, verified the calibration of more than 3300 clinical photon beams at approximately 1000 radiotherapy hospitals. Only 65% of those hospitals who receive TLDs for the first time have results within the acceptance limits, while more than 80% of the users that have benefited from a previous TLD audit are successful. The experience of the IAEA in TLD audits has been transferred to the national level. The IAEA offers a standardized TLD methodology, provides guidelines and gives technical back-up to the national TLD networks. Conclusion: The unsatisfactory status of the dosimetry for radiotherapy, as noted in the past, is gradually improving; however, the dosimetry practices in many hospitals in developing countries need to be revised in order to reach adequate conformity to hospitals that perform modern radiotherapy in Europe, USA and Australia. (C) 2000 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 27 条
[1]  
[Anonymous], 1995, GUID EXPR UNC MEAS
[2]  
BOUTILLON M, 1997, 13 M COM CONS ET MES
[3]   IAEA WHO CO-60 TELETHERAPY DOSIMETRY SERVICE USING MAILED LIF DOSIMETERS - A SURVEY OF RESULTS OBTAINED DURING 1975-1982 [J].
BOYD, AW ;
EISENLOHR, HH .
MEDICAL PHYSICS, 1983, 10 (04) :491-492
[4]   POSTAL DOSE INTERCOMPARISON OF CO-60 DOSIMETRY USING THERMO-LUMINESCENCE DOSIMETERS AMONG SECONDARY STANDARD DOSIMETRY LABORATORIES [J].
BOYD, AW ;
EISENLOHR, HH ;
GIRZIKOWSKY, R .
MEDICAL PHYSICS, 1982, 9 (01) :112-113
[5]   PRELIMINARY-RESULTS OF A QUALITY ASSURANCE NETWORK FOR RADIOTHERAPY CENTERS IN EUROPE [J].
DUTREIX, A ;
VANDERSCHUEREN, E ;
DERREUMAUX, S ;
CHAVAUDRA, J .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :97-101
[6]   QUALITY-CONTROL OF RADIOTHERAPY CENTERS IN EUROPE - BEAM CALIBRATION [J].
DUTREIX, A ;
DERREUMAUX, S ;
CHAVAUDRA, J ;
VANDERSCHUEREN, E .
RADIOTHERAPY AND ONCOLOGY, 1994, 32 (03) :256-264
[7]   IAEA-WHO CO-60 TELETHERAPY DOSIMETRY SERVICE USING MAILED LIF DOSIMETERS - SURVEY OF RESULTS OBTAINED DURING 1970-75 [J].
EISENLOHR, HH ;
JAYARAMAN, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01) :18-28
[8]  
FERREIRA IH, 1999, IN PRESS RADIOTHER O
[9]  
HANSON WF, 1994, P INT SEM EUR MIDDL, P121
[10]  
HANSON WF, 1997, 989 IAEA TECDOC, P165